Literature DB >> 28064127

An ultrasensitive sandwich-type electrochemical immunosensor based on the signal amplification system of double-deck gold film and thionine unite with platinum nanowire inlaid globular SBA-15 microsphere.

Ping Wang1, Mingdang Li2, Fubin Pei2, Yueyun Li2, Qing Liu2, Yunhui Dong2, Qingyan Chu3, Hongjun Zhu4.   

Abstract

A novel thionine unites with platinum nanowire inlaid globular SBA-15 (Pt NWs@g-SBA-15/Thi) not only utilizes as an efficient electrical signal probe but also constitutes an amplifying system with double-deck gold film (D-Au film) have been applied to the fabrication of sandwich-type immunosensor for detecting hepatitis B surface antigen (HBs Ag). The D-Au film can accelerate the electron transfer on the electrode interface due to the tunneling effect between the two Au films and can improve the load capacity of primary antibodies (Ab1) because of the good biocompatibility. The Pt NWs@g-SBA-15/Thi with uniform globular morphology not only can effectively reduce the spatial limitation for loading the secondary antibodies (Ab2) but also can provide outstanding pore accessibility of guest species from outside and offer catalytically active sites in a large scale. Besides, the presence of Thi can well enhance the electrical conductivity of Pt NWs@g-SBA-15/Thi. With the good cooperation between D-Au film and Pt NWs@g-SBA-15/Thi, a linear relationship between current signals and the concentrations of HBs Ag was obtained in the wide range from 10 fg/mL to 100ng/mL and the detection limit of HBs Ag was 3.3 fg/mL (signal-to-noise ratio of 3). Furthermore, the designed immunosensor with excellent selectivity, reproducibility and stability shows excellent performance in detection of human serum samples and provides a promising capacity for detecting a wide range of other tumor markers in clinical application.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Double-deck gold film; Globular SBA-15; Hepatitis B surface antigen; Platinum nanowire; Sandwich-type immunosensor

Mesh:

Substances:

Year:  2016        PMID: 28064127     DOI: 10.1016/j.bios.2016.12.057

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  An electrochemical sandwich immunosensor for cardiac troponin I by using nitrogen/sulfur co-doped graphene oxide modified with Au@Ag nanocubes as amplifiers.

Authors:  Hui Lv; Xiaobo Zhang; Yueyun Li; Yong Ren; Chunyan Zhang; Ping Wang; Zhen Xu; Xinjin Li; Zhiwei Chen; Yunhui Dong
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

Review 2.  Recent Advances in Biosensor Development for Foodborne Virus Detection.

Authors:  Suresh Neethirajan; Syed Rahin Ahmed; Rohit Chand; John Buozis; Éva Nagy
Journal:  Nanotheranostics       Date:  2017-07-05

Review 3.  Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis.

Authors:  Il-Hoon Cho; Dong Hyung Kim; Sangsoo Park
Journal:  Biomater Res       Date:  2020-02-04