Literature DB >> 28063250

Comparative 3D micro-CT and 2D histomorphometry analysis of dental implant osseointegration in the maxilla of minipigs.

Oliver Bissinger1, Florian Andreas Probst2, Klaus-Dietrich Wolff1, Anke Jeschke3, Jochen Weitz1, Herbert Deppe1, Andreas Kolk1,4.   

Abstract

AIM: The bone implant contact (BIC) has traditionally been evaluated with histological methods. Thereupon, strong correlations of two-dimensional (2D) BIC have been detected between μCT and destructive histology. However, due to the high intra-sample variability in BIC values, one histological slice is not sufficient to represent 3D BIC. Therefore, our aim has been to correlate the averaged values of 3-4 histological sections to 3D μCT.
MATERIAL AND METHODS: Fifty-four implants inserted into the maxilla of 14 minipigs were evaluated. Two different time points were selected to assess the 3D BIC (distance to implant: 2-5 voxels), an inner ring (6-30 voxels) and an outer ring (55-100 voxels) using μCT (voxel size: 10 μm) and to correlate the values to histomorphometry.
RESULTS: Strong correlations (p < 0.0001; 28 days, 56 days, total) were seen between μCT and histomorphometry concerning BIC (r = 0.84, r = 0.85, r = 0.83), the inner ring (r = 0.87, r = 0.87, r = 0.88) and the outer ring (r = 0.85, r = 0.85, r = 0.88). Closer to the implant, μCT values were higher compared with histomorphometry.
CONCLUSION: Although 3-4 histological slices per implant seem to predict the 3D BIC, μCT might be advantageous because of its non-destructive 3D character. The healing time may not impact on the comparability.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone implant contact (BIC); bone volume/total volume (BV/TV); dental implants; histomorphometry; micro-CT (μCT); osseointegration

Mesh:

Substances:

Year:  2017        PMID: 28063250     DOI: 10.1111/jcpe.12693

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  11 in total

1.  Bone Texture Fractal Dimension Analysis of Ultrasound-Treated Bone around Implant Site: A Double-Blind Clinical Trial.

Authors:  Elaf Akram Abdulhameed; Natheer Hashim Al-Rawi; Asmaa Tahseen Uthman; Ab Rani Samsudin
Journal:  Int J Dent       Date:  2018-04-15

2.  An In Vivo Study in Rat Femurs of Bioactive Silicate Coatings on Titanium Dental Implants.

Authors:  Giulia Brunello; Lisa Biasetto; Hamada Elsayed; Elia Sbettega; Chiara Gardin; Anna Scanu; Simone Carmignato; Barbara Zavan; Stefano Sivolella
Journal:  J Clin Med       Date:  2020-04-29       Impact factor: 4.241

3.  Enhanced Osseointegration by the Hierarchical Micro-Nano Topography on Selective Laser Melting Ti-6Al-4V Dental Implants.

Authors:  Tianyu Shu; Yuchen Zhang; Guo Sun; Yang Pan; Gang He; Yilong Cheng; Ang Li; Dandan Pei
Journal:  Front Bioeng Biotechnol       Date:  2021-01-07

4.  Effect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study.

Authors:  Dandan Song; Sohaib Shujaat; Yan Huang; Jeroen Van Dessel; Constantinus Politis; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Int J Implant Dent       Date:  2021-02-18

5.  In-house 3D-printed surgical guides for osseous lesions of the lower jaw: an experimental study.

Authors:  Lukas Postl; Thomas Mücke; Stefan Hunger; Oliver Bissinger; Michael Malek; Svenia Holberg; Rainer Burgkart; Stefan Krennmair
Journal:  Eur J Med Res       Date:  2021-03-15       Impact factor: 2.175

6.  Coating Ti6Al4V implants with nanocrystalline diamond functionalized with BMP-7 promotes extracellular matrix mineralization in vitro and faster osseointegration in vivo.

Authors:  Ivana Nemcakova; Andrej Litvinec; Vaclav Mandys; Stepan Potocky; Martin Plencner; Martina Doubkova; Ondrej Nanka; Veronika Olejnickova; Barbora Sankova; Martin Bartos; Egor Ukraintsev; Oleg Babčenko; Lucie Bacakova; Alexander Kromka; Bohuslav Rezek; David Sedmera
Journal:  Sci Rep       Date:  2022-03-28       Impact factor: 4.379

7.  Biocompatibility evaluation of peo-treated magnesium alloy implants placed in rabbit femur condyle notches and paravertebral muscles.

Authors:  Seong Ryoung Kim; Keon Mo Lee; Jin Hong Kim; Young Jin Choi; Han Ick Park; Hwa Chul Jung; Hyung Jin Roh; Jee Hye Lo Han; Joon Rae Kim; Bu-Kyu Lee
Journal:  Biomater Res       Date:  2022-07-06

8.  A novel surgical model for the preclinical assessment of the osseointegration of dental implants: a surgical protocol and pilot study results.

Authors:  Noura M AlOtaibi; Michael Dunne; Ashraf F Ayoub; Kurt B Naudi
Journal:  J Transl Med       Date:  2021-06-28       Impact factor: 5.531

9.  Development of a quantitative preclinical screening model for implant osseointegration in rat tail vertebra.

Authors:  Sándor Farkasdi; Dávid Pammer; Róbert Rácz; Gergely Hriczó-Koperdák; Bence Tamás Szabó; Csaba Dobó-Nagy; Beáta Kerémi; József Blazsek; Frederic Cuisinier; Gang Wu; Gábor Varga
Journal:  Clin Oral Investig       Date:  2018-10-29       Impact factor: 3.573

10.  Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography.

Authors:  Jung-Yoo Chesaria Choi; Cham Albert Choi; In-Sung Luke Yeo
Journal:  J Periodontal Implant Sci       Date:  2018-08-29       Impact factor: 2.614

View more