Literature DB >> 28062041

Improved Force Spectroscopy Using Focused-Ion-Beam-Modified Cantilevers.

J K Faulk1, D T Edwards1, M S Bull1, T T Perkins2.   

Abstract

Atomic force microscopy (AFM) is widely used in biophysics, including force-spectroscopy studies of protein folding and protein-ligand interactions. The precision of such studies increases with improvements in the underlying quality of the data. Currently, data quality is limited by the mechanical properties of the cantilever when using a modern commercial AFM. The key tradeoff is force stability vs short-term force precision and temporal resolution. Here, we present a method that avoids this compromise: efficient focused-ion-beam (FIB) modification of commercially available cantilevers. Force precision is improved by reducing the cantilever's hydrodynamic drag, and force stability is improved by reducing the cantilever stiffness and by retaining a cantilever's gold coating only at its free end. When applied to a commonly used short cantilever (L=40μm), we achieved sub-pN force precision over 5 decades of bandwidth (0.01-1000Hz) without significantly sacrificing temporal resolution (~75μs). Extending FIB modification to an ultrashort cantilever (L=9μm) also improved force precision and stability, while maintaining 1-μs-scale temporal resolution. Moreover, modifying ultrashort cantilevers also eliminated their inherent underdamped high-frequency motion and thereby avoided applying a rapidly oscillating force across the stretched molecule. Importantly, fabrication of FIB-modified cantilevers is accessible after an initial investment in training. Indeed, undergraduate researchers routinely modify 2-4 cantilevers per hour with the protocol detailed here. Furthermore, this protocol offers the individual user the ability to optimize a cantilever for a particular application. Hence, we expect FIB-modified cantilevers to improve AFM-based studies over broad areas of biophysical research.
© 2017 Elsevier Inc. All rights reserved.

Keywords:  Atomic force microscopy; Cantilever dynamics; Focused-ion-beam modification; Protein folding; Single-molecule biophysics; Single-molecule force spectroscopy

Mesh:

Substances:

Year:  2016        PMID: 28062041     DOI: 10.1016/bs.mie.2016.08.007

Source DB:  PubMed          Journal:  Methods Enzymol        ISSN: 0076-6879            Impact factor:   1.600


  7 in total

1.  Type III secretion system effector proteins are mechanically labile.

Authors:  Marc-André LeBlanc; Morgan R Fink; Thomas T Perkins; Marcelo C Sousa
Journal:  Proc Natl Acad Sci U S A       Date:  2021-03-23       Impact factor: 11.205

2.  Force Spectroscopy with 9-μs Resolution and Sub-pN Stability by Tailoring AFM Cantilever Geometry.

Authors:  Devin T Edwards; Jaevyn K Faulk; Marc-André LeBlanc; Thomas T Perkins
Journal:  Biophys J       Date:  2017-11-11       Impact factor: 4.033

3.  Warhammers for Peaceful Times.

Authors:  Piotr E Marszalek
Journal:  Biophys J       Date:  2018-01-09       Impact factor: 4.033

4.  Membrane-Protein Unfolding Intermediates Detected with Enhanced Precision Using a Zigzag Force Ramp.

Authors:  David R Jacobson; Lyle Uyetake; Thomas T Perkins
Journal:  Biophys J       Date:  2019-12-13       Impact factor: 4.033

5.  Free-energy changes of bacteriorhodopsin point mutants measured by single-molecule force spectroscopy.

Authors:  David R Jacobson; Thomas T Perkins
Journal:  Proc Natl Acad Sci U S A       Date:  2021-03-30       Impact factor: 11.205

6.  Modulation of a protein-folding landscape revealed by AFM-based force spectroscopy notwithstanding instrumental limitations.

Authors:  Devin T Edwards; Marc-Andre LeBlanc; Thomas T Perkins
Journal:  Proc Natl Acad Sci U S A       Date:  2021-03-23       Impact factor: 12.779

Review 7.  High-speed force spectroscopy: microsecond force measurements using ultrashort cantilevers.

Authors:  Claire Valotteau; Fidan Sumbul; Felix Rico
Journal:  Biophys Rev       Date:  2019-10-07
  7 in total