Literature DB >> 28057440

New web-based algorithm to improve rigid gas permeable contact lens fitting in keratoconus.

Sara Ortiz-Toquero1, Guadalupe Rodriguez1, Victoria de Juan2, Raul Martin3.   

Abstract

PURPOSE: To calculate and validate a new web-based algorithm for selecting the back optic zone radius (BOZR) of spherical gas permeable (GP) lens in keratoconus eyes.
METHODS: A retrospective calculation (n=35; multiple regression analysis) and a posterior prospective validation (new sample of 50 keratoconus eyes) of a new algorithm to select the BOZR of spherical KAKC design GP lenses (Conoptica) in keratoconus were conducted. BOZR calculated with the new algorithm, manufacturer guidelines and APEX software were compared with the BOZR that was finally prescribed. Number of diagnostic lenses, ordered lenses and visits to achieve optimal fitting were recorded and compared those obtained for a control group [50 healthy eyes fitted with spherical GP (BIAS design; Conoptica)].
RESULTS: The new algorithm highly correlated with the final BOZR fitted (r2=0.825, p<0.001). BOZR of the first diagnostic lens using the new algorithm demonstrated lower difference with the final BOZR prescribed (-0.01±0.12mm, p=0.65; 58% difference≤0.05mm) than with the manufacturer guidelines (+0.12±0.22mm, p<0.001; 26% difference≤0.05mm) and APEX software (-0.14±0.16mm, p=0.001; 34% difference≤0.05mm). Close numbers of diagnostic lens (1.6±0.8, 1.3±0.5; p=0.02), ordered lens (1.4±0.6, 1.1±0.3; P<0.001), and visits (3.4±0.7, 3.2±0.4; p=0.08) were required to fit keratoconus and healthy eyes, respectively.
CONCLUSION: This new algorithm (free access at www.calculens.com) improves spherical KAKC GP fitting in keratoconus and can reduce the practitioner and patient chair time to achieve a final acceptable fit in keratoconus. This algorithm reduces differences between keratoconus GP fitting (KAKC design) and standard GP (BIAS design) lenses fitting in healthy eyes.
Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Algorithm; Contact lens; Gas permeable; Keratoconus

Mesh:

Year:  2017        PMID: 28057440     DOI: 10.1016/j.clae.2016.12.009

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

Review 1.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

Review 2.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

3.  Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations.

Authors:  Sara Ortiz-Toquero; Guadalupe Rodriguez; Victoria de Juan; Raul Martin
Journal:  Indian J Ophthalmol       Date:  2019-09       Impact factor: 1.848

4.  Initial Power of Rigid Gas Permeable Contact Lenses in Patients with Keratoconus.

Authors:  Fereshteh Birjandi; Hadi Ostadimoghaddam; Abbasali Yekta; Monireh Mahjoob
Journal:  J Curr Ophthalmol       Date:  2022-01-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.