Literature DB >> 2805473

Mechanisms of failure of the femoral and tibial components in total knee arthroplasty.

R E Windsor1, G R Scuderi, M C Moran, J N Insall.   

Abstract

From 1974 to 1986, 1430 cemented primary total knee arthroplasties were available for analysis. These included 224 total condylar prostheses with a polyethylene tibial component, 289 posterior stabilized prostheses with a polyethylene tibial component, and 917 posterior stabilized prostheses with a metal-backed tibial component. There were 12 failures in the total condylar series including three infections (one early and two late), five loose tibial components, two loose femoral and tibial components, and two unstable arthroplasties. The posterior stabilized prosthesis with the polyethylene tibia demonstrated six failures including two loose tibial components, two loose femoral components, and one supracondylar femur fracture. The posterior stabilized prosthesis with the metal-backed tibial component was associated with seven failures including six infections (three early and three late) and one femoral loosening. No metal-backed tibial components have been revised for loosening. The overall failure rate in this series was 1.7% for all prostheses. The incidence of tibial loosening was 0.53% with an average time to failure of 4.7 years. The incidence of femoral loosening was 0.35% with an average time to failure of 2.0 years. Tibial loosening was related to error in technique: postoperative varus tibiofemoral alignment, varus tibial component position, and excessive tibial resection. The overall infection rate was 0.63% for all total knee arthroplasties, and all were secondary to gram-positive organisms. Presently, the posterior stabilized prosthesis with a metal-backed tibia is the authors' implant of choice. Technical error and infection are the major causes of failure.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2805473     DOI: 10.1097/00003086-198911000-00005

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  40 in total

1.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

2.  Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Kiyonori Mizuno; Keisuke Kinoshita; Kazunari Ishida; Takehiko Matsushita; Ken Sasaki; Katsumasa Tei; Koji Takayama; Hiroshi Sasaki; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-03       Impact factor: 4.342

3.  Novel computer-assisted method for revision arthroplasty of the knee.

Authors:  Hanns-Edgar Hoffart; Harald Dinges; Stefan Kolbeck; Peter Ritschl; Hagen Hommel
Journal:  World J Orthop       Date:  2015-11-18

4.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

5.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

6.  Less invasive TKA: extramedullary femoral reference without navigation.

Authors:  Andrea Baldini; Paolo Adravanti
Journal:  Clin Orthop Relat Res       Date:  2008-08-19       Impact factor: 4.176

7.  Computer-assisted revision of total knee arthroplasty.

Authors:  Aymard de Ladoucette
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-21       Impact factor: 4.342

8.  Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection.

Authors:  Dae-Hee Lee; Jong-Hoon Park; Dong-Ik Song; Debabrata Padhy; Woong-Kyo Jeong; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-03       Impact factor: 4.342

9.  Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.

Authors:  Tilman Pfitzner; Matthew P Abdel; Philipp von Roth; Carsten Perka; Hagen Hommel
Journal:  Clin Orthop Relat Res       Date:  2014-07-15       Impact factor: 4.176

10.  Unconstrained total knee arthroplasty in significant valgus deformity: a modified surgical technique to balance the knee and avoid instability.

Authors:  R Pagoti; S O'Brien; E Doran; D Beverland
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-28       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.