Literature DB >> 28053441

New Wavenumber Calibration Tables From Heterodyne Frequency Measurements.

Arthur G Maki1, Joseph S Wells2.   

Abstract

This new calibration atlas is based on frequency rather than wavelength calibration techniques for absolute references. Since a limited number of absolute frequency measurements is possible, additional data from alternate methodology are used for difference frequency measurements within each band investigated by the frequency measurements techniques. Data from these complementary techniques include the best Fourier transform measurements available. Included in the text relating to the atlas are a description of the heterodyne frequency measurement techniques and details of the analysis, including the Hamiltonians and least-squares-fitting and calculation. Also included are other relevant considerations such as intensities and lincshape parameters. A 390-entry bibliography which contains all data sources used and a subsequent section on errors conclude the text portion. The primary calibration molecules are the linear triatomics, carbonyl sulfide and nitrous oxide, which cover portions of the infrared spectrum ranging from 488 to 3120 cm-1. Some gaps in the coverage afforded by OCS and N2O are partially covered by NO, CO, and CS2. An additional region from 4000 to 4400 cm-1 is also included. The tabular portion of the atlas is too lengthy to include in an archival journal. Furthermore, different users have different requirements for such an atlas. In an effort to satisfy most users, we have made two different options available. The first is NIST Special Publication 821, which has a spectral map/facing table format. The spectral maps (as well as the facing tables) are calculated from molecular constants derived for the work. A complete list of all of the molecular transitions that went into making the maps is too long (perhaps by a factor of 4 or 5) to include in the facing tables. The second option for those not interested in maps (or perhaps to supplement Special Publication 821) is the complete list (tables-only) which is available in computerized format as NIST Standard Reference Database #39, Wavelength Calibration Tables.

Entities:  

Keywords:  IR frequency calibrations; IR wavenumber calibrations; calibration atlas; carbon disulfide; carbon monoxide; carbonyl sulfide; nitric oxide; nitrous oxide; wavenumber tables

Year:  1992        PMID: 28053441      PMCID: PMC4927226          DOI: 10.6028/jres.097.019

Source DB:  PubMed          Journal:  J Res Natl Inst Stand Technol        ISSN: 1044-677X


  1 in total

1.  Argon I Lines Produced in a Hollow Cathode Source, 332 nm to 5865 nm.

Authors:  W Whaling; W H C Anderson; M T Carle; J W Brault; H A Zarem
Journal:  J Res Natl Inst Stand Technol       Date:  2002-04-01
  1 in total