Literature DB >> 28050517

Prosthodontic Approach in Management of Prolonged Neonatal Intubation.

Vikas B Kamble1, Shital K Shah2, Vishnu B Rathod3, Priyanka S Ambadkar4, Charudutt N Patil4.   

Abstract

Intubation is a routine intervention in the Neonatal Intensive Care Unit (NICU) for preterm neonates with respiratory distress, inadequate gag reflex, poor sucking and swallowing. Prolonged intubation in neonates can be done by nasal or oral route. Although naso-tracheal intubation may reduce movement of the tube, it may contribute to airway obstruction, possible hypoxia, and occlusion of the nasal aperture during a crucial period of development further contributing to laboured breathing. Being obligate nasal breathers, oro-tracheal route is the preferred method of intubation in premature infants as oral mucosa is less susceptible to damage than nasal mucosa. Ineffective stabilization of the tubes is a frequent problem often resulting in accidental extubation and displacement of orotracheal and orogastric tube. Hence, these tubes must be stabilized against displacement from tongue and jaw movements to prevent discomfort and subsequent tissue trauma. Complications of prolonged endotracheal intubation include palatal groove formation by pressure against the hard palate, infection, accidental extubation, malposition, laryngeal or tracheal edema and ulceration, tracheal stenosis, vocal cord injury. Various oral appliances are used for infants to stabilize the tubes and prevent complications associated with long term intubation. This case report describes a prosthodontic approach in management of prolonged neonatal intubation.

Entities:  

Keywords:  Endotracheal intubation; Neonate; Orogastric Intubation; Prolonged intubation

Year:  2016        PMID: 28050517      PMCID: PMC5198470          DOI: 10.7860/JCDR/2016/22408.8863

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  8 in total

1.  Oropharyngeal airway appliance for infant with upper airway obstruction: report of a case.

Authors:  T Shimoyama; T Kato; Norio Horie; D Nasu; T Kaneko
Journal:  J Clin Pediatr Dent       Date:  2002       Impact factor: 1.065

2.  Neonatal palatal appliance: light-cured resin material and flexible design.

Authors:  J W McCourt
Journal:  Pediatr Dent       Date:  1992 Jul-Aug       Impact factor: 1.874

3.  An intra-oral appliance to stabilise orogastric tube in premature infants.

Authors:  P G Sullivan; H Haringman
Journal:  Lancet       Date:  1981-02-21       Impact factor: 79.321

4.  Dental management of neonates requiring prolonged oral intubation.

Authors:  A S von Gonten; J B Meyer; A K Kim
Journal:  J Prosthodont       Date:  1995-12       Impact factor: 2.752

5.  A method for securing pediatric endotracheal tubes.

Authors:  S D Richards
Journal:  Anesth Analg       Date:  1981-04       Impact factor: 5.108

6.  Prolonged intubation of neonates.

Authors:  S K Dankle; D E Schuller; R E McClead
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1987-08

7.  Appliance for stabilizing orogastric and orotracheal tubes in infants.

Authors:  A Erenberg; A J Nowak
Journal:  Crit Care Med       Date:  1984-08       Impact factor: 7.598

8.  Nursing management of the infant with an intraoral appliance.

Authors:  G Budreau; C Kleiber
Journal:  J Obstet Gynecol Neonatal Nurs       Date:  1987 Jan-Feb