Literature DB >> 12413168

Oropharyngeal airway appliance for infant with upper airway obstruction: report of a case.

T Shimoyama1, T Kato, Norio Horie, D Nasu, T Kaneko.   

Abstract

A palatal appliance with oropharyngeal tube that reduces the upper airway obstructions of an eleven-month-old male infant with severe cerebral palsy is presented. The palatal appliance was composed of the base plate, the outer guide tube that held the oropharyngeal tube inside it, and the extra outer guide tube for the suction catheter. After the setting of the appliance, respiratory distress was improved without side effects.

Entities:  

Mesh:

Year:  2002        PMID: 12413168     DOI: 10.17796/jcpd.27.1.69h1nxnt137p060q

Source DB:  PubMed          Journal:  J Clin Pediatr Dent        ISSN: 1053-4628            Impact factor:   1.065


  1 in total

1.  Prosthodontic Approach in Management of Prolonged Neonatal Intubation.

Authors:  Vikas B Kamble; Shital K Shah; Vishnu B Rathod; Priyanka S Ambadkar; Charudutt N Patil
Journal:  J Clin Diagn Res       Date:  2016-11-01