Literature DB >> 28050495

Computed Tomography Evaluation of Canal Transportation and Volumetric Changes in Root Canal Dentin of Curved Canals Using Mtwo, ProTaper and ProTaper Next Rotary System-An In-vitro Study.

Mayuri Biccodu Shivashankar1, Nandini Thippannanavar Niranjan2, Arun Jayasheel3, Mallikarjun Goud Kenchanagoudra4.   

Abstract

INTRODUCTION: Complete cleaning and shaping of root canal system is of paramount importance to achieve a successful root canal treatment. There are various rotary Ni-Ti systems available in the market to achieve mechanical goal of root canal preparation. But aggressive preparation of root canal with such systems would result in canal transportation and excess root dentin removal that would be one of the major reasons to decide the prognosis of root canal treated tooth. AIM: The present study was conducted to compare the root canal preparation in terms of canal transportation and volumetric changes in the root canal dentin among three Ni-Ti file systems, namely Mtwo, ProTaper (PT) and ProTaper NEXT (PTN) file system, using Computed Tomography (CT).
MATERIALS AND METHODS: A total of 45 mesiobuccal root canals of extracted first molar teeth with completely formed root apices and angle of curvature ranging between 10°- 35° were selected. These teeth were randomly divided into three experimental groups containing 15 teeth each, based on rotary system used. Group-I: Mtwo files, Group-II: PT files and Group-III: PTN files. Pre-instrumentation CT images were obtained at three cross-sectional planes - 3mm, 7mm and 11mm from apical end of the root. Similarly, post-instrumentation images were obtained. Shortest distance from the edge of the canal to the periphery of the root was analyzed by using Analysis of Variance.
RESULTS: All three file systems tested in the present study presented similar behaviour with respect to the root canal transportation. Lesser canal transportation was recorded in Mtwo. But no statistically significant difference was seen in terms of canal transportation and volume of dentin removed between all three rotary systems (p>0.05).
CONCLUSION: Mtwo, PT and PTN rotary systems have similar behaviour with respect to canal transportation and volume of dentin removed.

Keywords:  3D imaging; Ni-Ti file system; Root canal treatment

Year:  2016        PMID: 28050495      PMCID: PMC5198448          DOI: 10.7860/JCDR/2016/20373.8788

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  25 in total

1.  Shaping ability of Hero 642 rotary nickel-titanium instruments in simulated root canals: Part 2.

Authors:  S A Thompson; P M Dummer
Journal:  Int Endod J       Date:  2000-05       Impact factor: 5.264

2.  Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in simulated root canals.

Authors:  S T Bryant; P M Dummer; C Pitoni; M Bourba; S Moghal
Journal:  Int Endod J       Date:  1999-05       Impact factor: 5.264

3.  ProTaper rotary root canal preparation: assessment of torque and force in relation to canal anatomy.

Authors:  O A Peters; C I Peters; K Schönenberger; F Barbakow
Journal:  Int Endod J       Date:  2003-02       Impact factor: 5.264

4.  ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT.

Authors:  O A Peters; C I Peters; K Schönenberger; F Barbakow
Journal:  Int Endod J       Date:  2003-02       Impact factor: 5.264

5.  Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography.

Authors:  Senem Yiğit Özer
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-12-16

6.  Cutting efficiency of twisted versus machined nickel-titanium endodontic files.

Authors:  Dalia Mukhtar Fayyad; Abeer A Elhakim Elgendy
Journal:  J Endod       Date:  2011-05-17       Impact factor: 4.171

7.  Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography.

Authors:  J M Gambill; M Alder; C E del Rio
Journal:  J Endod       Date:  1996-07       Impact factor: 4.171

8.  Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals.

Authors:  Ismail Davut Capar; Huseyin Ertas; Evren Ok; Hakan Arslan; Elif Tarim Ertas
Journal:  J Endod       Date:  2013-11-07       Impact factor: 4.171

9.  Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation.

Authors:  A Guelzow; O Stamm; P Martus; A M Kielbassa
Journal:  Int Endod J       Date:  2005-10       Impact factor: 5.264

10.  Shaping Ability of 5(th) Generation Ni-Ti Rotary Systems for Root Canal Preparation in Curved Root Canals using CBCT: An In Vitro Study.

Authors:  Jain Deepak; Medha Ashish; Neelam Patil; Nilam Kadam; Vandana Yadav; Harshal Jagdale
Journal:  J Int Oral Health       Date:  2015
View more
  6 in total

1.  Effects of continuous chelation on the instrumentation of curved canals with a martensitic NiTi file system: an ex vivo micro-CT evaluation.

Authors:  M Sobrino; F Foschi; R Estévez; G Loroño; A Conde Villar; R Pérez-Alfayate
Journal:  Odontology       Date:  2022-07-07       Impact factor: 2.634

2.  Cone-beam computed tomography assessment of root canal transportation using WaveOne Gold and Neoniti single-file systems.

Authors:  Saritha Vallabhaneni; Kainath Fatima; Twino H Kumar
Journal:  J Conserv Dent       Date:  2017 Nov-Dec

3.  Comparative evaluation of the shaping ability of single-file system versus multi-file system in severely curved root canals.

Authors:  Guohua Yuan; Guobin Yang
Journal:  J Dent Sci       Date:  2018-02-01       Impact factor: 2.080

4.  Comparison of Shaping Ability of Different Single-File Systems Using Microcomputed Tomography.

Authors:  Mohamed Mohamed Elashiry; Shehab Eldin Saber; Salma Hasan Elashry
Journal:  Eur J Dent       Date:  2020-01-31

5.  Shaping ability of four single-file systems in the instrumentation of second mesiobuccal canals of three-dimensional printed maxillary first molars.

Authors:  Fulu Xu; Yuerong Zhang; Yongchun Gu; Yifan Ping; Ruyu Zhou; Juan Wang
Journal:  Ann Transl Med       Date:  2021-09

6.  Evaluation of Root Dentin Thickness and Smear Layer Removal Efficacy of Two Novel Nickel Titanium Rotary Instruments - An In Vitro Cone-Beam Computed Tomography and Scanning Electron Microscopy Study.

Authors:  Gangili Sparsha Reddy; Rajeswari Kalaiselvam; Arasappan Rajakumaran; Manigandan Kuzhanchinathan; Ram Sabarish; Arathi Ganesh
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.