Literature DB >> 28049865

Adherence of volatile propofol to various types of plastic tubing.

F Maurer1, D J Lorenz, G Pielsticker, T Volk, D I Sessler, J I Baumbach, S Kreuer.   

Abstract

Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration. Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFA or PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol, with PTFE as an alternative.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28049865     DOI: 10.1088/1752-7163/aa567e

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  5 in total

Review 1.  [Modern breath analysis].

Authors:  L M Wirtz; S Kreuer; T Volk; T Hüppe
Journal:  Med Klin Intensivmed Notfmed       Date:  2019-02-06       Impact factor: 0.840

2.  Humidity and measurement of volatile propofol using MCC-IMS (EDMON).

Authors:  Tobias Teucke; F Maurer; L M Müller-Wirtz; T Volk; D I Sessler; S Kreuer
Journal:  J Clin Monit Comput       Date:  2022-09-21       Impact factor: 1.977

Review 3.  Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.

Authors:  M Ariel Geer Wallace; Joachim D Pleil
Journal:  Anal Chim Acta       Date:  2018-02-09       Impact factor: 6.558

4.  Correlation of exhaled propofol with Narcotrend index and calculated propofol plasma levels in children undergoing surgery under total intravenous anesthesia - an observational study.

Authors:  Sebastian Heiderich; Tara Ghasemi; Nils Dennhardt; Robert Sümpelmann; Vanessa Rigterink; Katja Nickel; Oliver Keil; Dietmar Böthig; Christiane E Beck
Journal:  BMC Anesthesiol       Date:  2021-05-26       Impact factor: 2.217

5.  Online exhaled propofol monitoring in normal-weight and obese surgical patients.

Authors:  Martin R Braathen; Ivan Rimstad; Terje Dybvik; Ståle Nygård; Johan Raeder
Journal:  Acta Anaesthesiol Scand       Date:  2022-02-19       Impact factor: 2.274

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.