Literature DB >> 2804427

High performance liquid chromatography determination of cyanide in urine by pre-column fluorescence derivatization.

A Sano1, M Takezawa, S Takitani.   

Abstract

A method for the determination of cyanide in human urine has been developed. The method is based on the reaction of cyanide with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product for reversed-phase HPLC separation and fluorometric detection. After centrifugation followed by dilution of urine samples, the specimens could be analysed directly by this method. The recovery of cyanide added to urine at concentration levels of 50-1000 pmol/mL was 85-96%. The detection limit of cyanide was 30 pmol/mL in urine. The method was successfully applied to the analysis of urine from smokers and nonsmokers. The mean concentrations of cyanide were found to be 215 pmol/mL for the former and 84 pmol/mL for the latter.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2804427     DOI: 10.1002/bmc.1130030507

Source DB:  PubMed          Journal:  Biomed Chromatogr        ISSN: 0269-3879            Impact factor:   1.902


  6 in total

1.  Structural basis of enzymatic benzene ring reduction.

Authors:  Tobias Weinert; Simona G Huwiler; Johannes W Kung; Sina Weidenweber; Petra Hellwig; Hans-Joachim Stärk; Till Biskup; Stefan Weber; Julien J H Cotelesage; Graham N George; Ulrich Ermler; Matthias Boll
Journal:  Nat Chem Biol       Date:  2015-06-29       Impact factor: 15.040

2.  Alternate injections coupled with flow-gated capillary electrophoresis for rapid and accurate quantitative analysis of urine samples.

Authors:  Qingfu Zhu; Qiyang Zhang; Ning Zhang; Maojun Gong
Journal:  Anal Chim Acta       Date:  2017-05-06       Impact factor: 6.558

3.  Development of a cost-effective laser diode-induced fluorescence detection instrument for cyanide detection.

Authors:  Yasuhiro Morikawa; Keiji Nishiwaki; Shigeo Suzuki; Mitsuhiro Kinoshita; Isao Nakanishi
Journal:  Anal Sci       Date:  2022-02-18       Impact factor: 2.081

4.  A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

Authors:  Qiyang Zhang; Naveen Maddukuri; Maojun Gong
Journal:  J Chromatogr A       Date:  2015-08-28       Impact factor: 4.759

5.  The analysis of 2-amino-2-thiazoline-4-carboxylic acid in the plasma of smokers and non-smokers.

Authors:  Brian A Logue; Wendy K Maserek; Gary A Rockwood; Michael W Keebaugh; Steven I Baskin
Journal:  Toxicol Mech Methods       Date:  2009-03       Impact factor: 2.987

Review 6.  Cyanides in the environment-analysis-problems and challenges.

Authors:  Ewa Jaszczak; Żaneta Polkowska; Sylwia Narkowicz; Jacek Namieśnik
Journal:  Environ Sci Pollut Res Int       Date:  2017-05-16       Impact factor: 4.223

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.