Literature DB >> 28042607

Reliability of a 3D Body Scanner for Anthropometric Measurements of Central Obesity.

Jose Medina-Inojosa1, Virend K Somers1, Taiwo Ngwa2, Ling Hinshaw1, Francisco Lopez-Jimenez1.   

Abstract

BACKGROUND: Central obesity poses a significant risk for cardiovascular diseases, but the reproducibility of manual measurements of waist and hip circumferences has been questioned. An automated 3D body scanner that uses white light rays could potentially increase the reliability of these anthropometric measurements.
METHODS: We assessed the reproducibility of anthropometric measurements performed manually and using a 3D-scanner in 83 adult volunteers. Manual measures of WC and HC were obtained using unmarked, non-elastic ribbons in order to avoid observer and confirmation bias. The 3D-scanner was used to create body images and to obtain WC and HC measurements in an automated fashion.
RESULTS: The inter-observer mean differences were 3.9 ± 2.4 cm for WC; 2.7 ± 2.4 cm, for HC, and 0.006 ± 0.02 cm for WHR. Intra-observer mean differences for manual measurements were 3.1 ± 1.9 cm for WC, 1.8 ± 2.2 cm for HC and 0.11 ± 0.1 cm for WHR. The 3D-scanner variability for WC was 1.3 ± 0.9 cm, for HC was 0.8 ± 0.1 and 0.005 ± 0.01 cm for WHR. All means were significantly different (p<0.05) between manual and automated methods.
CONCLUSION: The 3D-scanner is a more reliable and reproducible method for measuring WC, HC and WHR to detect central obesity.

Entities:  

Keywords:  3D-scanner; Central obesity; Hip circumference; Obesity; Waist circumference; Waist-to-hip ratio

Year:  2016        PMID: 28042607      PMCID: PMC5189636          DOI: 10.16966/2380-5528.122

Source DB:  PubMed          Journal:  Obes Open Access        ISSN: 2380-5528


  21 in total

Review 1.  Clinical Guidelines on the Identification, Evaluation, and Treatment of Overweight and Obesity in Adults--The Evidence Report. National Institutes of Health.

Authors: 
Journal:  Obes Res       Date:  1998-09

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Obesity and the risk of myocardial infarction in 27,000 participants from 52 countries: a case-control study.

Authors:  Salim Yusuf; Steven Hawken; Stephanie Ounpuu; Leonelo Bautista; Maria Grazia Franzosi; Patrick Commerford; Chim C Lang; Zvonko Rumboldt; Churchill L Onen; Liu Lisheng; Supachai Tanomsup; Paul Wangai; Fahad Razak; Arya M Sharma; Sonia S Anand
Journal:  Lancet       Date:  2005-11-05       Impact factor: 79.321

Review 4.  Value and limitations of existing scores for the assessment of cardiovascular risk: a review for clinicians.

Authors:  Marie Therese Cooney; Alexandra L Dudina; Ian M Graham
Journal:  J Am Coll Cardiol       Date:  2009-09-29       Impact factor: 24.094

5.  Effect of the site of measurement of waist circumference on the prevalence of the metabolic syndrome.

Authors:  Caitlin Mason; Peter T Katzmarzyk
Journal:  Am J Cardiol       Date:  2009-04-16       Impact factor: 2.778

6.  Regional body volumes, BMI, waist circumference, and percentage fat in severely obese adults.

Authors:  Jack Wang; Dympna Gallagher; John C Thornton; Wen Yu; Rich Weil; Betty Kovac; F Xavier Pi-Sunyer
Journal:  Obesity (Silver Spring)       Date:  2007-11       Impact factor: 5.002

7.  Reliability of doctors' anthropometric measurements to detect obesity.

Authors:  Paul Sebo; Sigrid Beer-Borst; Dagmar M Haller; Patrick A Bovier
Journal:  Prev Med       Date:  2008-06-21       Impact factor: 4.018

8.  Physical inactivity, abdominal obesity and risk of coronary heart disease in apparently healthy men and women.

Authors:  B J Arsenault; J S Rana; I Lemieux; J-P Després; J J P Kastelein; S M Boekholdt; N J Wareham; K-T Khaw
Journal:  Int J Obes (Lond)       Date:  2009-11-17       Impact factor: 5.095

9.  Normal-Weight Central Obesity: Implications for Total and Cardiovascular Mortality.

Authors:  Karine R Sahakyan; Virend K Somers; Juan P Rodriguez-Escudero; David O Hodge; Rickey E Carter; Ondrej Sochor; Thais Coutinho; Michael D Jensen; Véronique L Roger; Prachi Singh; Francisco Lopez-Jimenez
Journal:  Ann Intern Med       Date:  2015-11-10       Impact factor: 25.391

10.  Abdominal obesity is strongly associated with Cardiovascular Disease and its Risk Factors in Elderly and very Elderly Community-dwelling Chinese.

Authors:  Huimin Fan; Xiaolin Li; Liang Zheng; Xiaoli Chen; Qin Lan; Hong Wu; Xugang Ding; Dingguang Qian; Yixin Shen; Zuoren Yu; Lieying Fan; Ming Chen; Brian Tomlinson; Paul Chan; Yuzhen Zhang; Zhongmin Liu
Journal:  Sci Rep       Date:  2016-02-17       Impact factor: 4.379

View more
  7 in total

1.  Accuracy of a handheld 3D imaging system for child anthropometric measurements in population-based household surveys and surveillance platforms: an effectiveness validation study in Guatemala, Kenya, and China.

Authors:  Karim Bougma; Zuguo Mei; Mireya Palmieri; Dickens Onyango; Jianmeng Liu; Karla Mesarina; Victor Akelo; Rael Mwando; Yubao Zhou; Ying Meng; Maria Elena Jefferds
Journal:  Am J Clin Nutr       Date:  2022-07-06       Impact factor: 8.472

2.  Digital anthropometry for body circumference measurements: Toward the development of universal three-dimensional optical system analysis software.

Authors:  Sima Sobhiyeh; Samantha Kennedy; Alexander Dunkel; Marcelline E Dechenaud; Jerome A Weston; John Shepherd; Peter Wolenski; Steven B Heymsfield
Journal:  Obes Sci Pract       Date:  2020-11-06

3.  The Effect of Replacing Sitting With Standing on Cardiovascular Risk Factors: A Systematic Review and Meta-analysis.

Authors:  Farzane Saeidifard; Jose R Medina-Inojosa; Marta Supervia; Thomas P Olson; Virend K Somers; Larry J Prokop; Gorazd B Stokin; Francisco Lopez-Jimenez
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2020-12-01

4.  Verification of Usability of Medical Image Data Using Projective Photography for Designing Clothing for Breast Cancer Patients.

Authors:  Youn Joo Kim
Journal:  Tomography       Date:  2022-07-14

5.  The smart body concept as a demonstration of the overarching utility and benefits of 3D avatars in retail, health and wellbeing: an accuracy study of body measures from 3D reconstruction.

Authors:  Veronica Cimolin; Ioannis Th Paraskevopoulos; Maurizio Sala; Marco Tarabini; Manuela Galli
Journal:  Multimed Tools Appl       Date:  2022-09-13       Impact factor: 2.577

Review 6.  Comparison of Body Scanner and Manual Anthropometric Measurements of Body Shape: A Systematic Review.

Authors:  Lorena Rumbo-Rodríguez; Miriam Sánchez-SanSegundo; Rosario Ferrer-Cascales; Nahuel García-D'Urso; Jose A Hurtado-Sánchez; Ana Zaragoza-Martí
Journal:  Int J Environ Res Public Health       Date:  2021-06-08       Impact factor: 3.390

Review 7.  Anthropometric Indicators as a Tool for Diagnosis of Obesity and Other Health Risk Factors: A Literature Review.

Authors:  Paola Piqueras; Alfredo Ballester; Juan V Durá-Gil; Sergio Martinez-Hervas; Josep Redón; José T Real
Journal:  Front Psychol       Date:  2021-07-09
  7 in total