Incidence of Ceramic Liner Malseating After Ceramic-on-Ceramic Total Hip Arthroplasty Associated With Osteolysis: A 5- to 15-Year Follow-Up Study.

Yoshitoshi Higuchi1, Yukiharu Hasegawa1, Daigo Komatsu1, Taisuke Seki1, Naoki Ishiguro1.   

Abstract

BACKGROUND: The aim of our study was to evaluate the clinical and radiographic outcomes of malseating of the acetabular liner in ceramic-on-ceramic total hip arthroplasty (THA).
METHODS: Outcomes for 160 ceramic-on-ceramic THAs, contributed by 116 women and 39 men, were evaluated. Clinical and radiographic measurements were obtained over a 5- to 15-year follow-up for analysis.
RESULTS: Liner malseating was identified in 20% of cases. Outcomes for 32 cases with liner malseating (group A) were compared to outcomes for 128 joints with correct liner seating (group B). The Harris hip score at the last follow-up was 90.1 for group A and 89.6 for group B. Osteolysis was identified in 5 cases in group A (15.6%), compared to 3 cases in group B (P < .001). No significant between-group differences were identified with regard to ceramic fracture, audible squeaking, loosening of components, and revision THA. The mean annual liner wear rate was comparable between groups, 0.0045 mm/y for group A and 0.0039 mm/y for group B. The 10-year Kaplan-Meier survivorship, based on an end point of revision THA, was 100% for group A and 99.0% for group B.
CONCLUSION: Over a moderate-length follow-up of 5-15 years, malseating of the acetabular liner was not associated with negative clinical outcomes or THA survivorship. Malseating did increase the incidence of osteolysis, a risk factor for adverse effects. Long-term follow-up studies are needed to fully quantify the effects of malseating of the acetabular liner.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ceramic-on-ceramic bearings; complication; liner malseating; long-term follow-up; total hip arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 28012723     DOI: 10.1016/j.arth.2016.11.044

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  Third and fourth generation ceramic-on-ceramic total hip arthroplasty at a minimum of ten years.

Authors:  Cathal J McCarthy; John Mahon; Gerard A Sheridan; Adanna Welch-Phillips; John M O'Byrne; Paddy J Kenny
Journal:  J Clin Orthop Trauma       Date:  2022-07-06

2.  Spontaneous resolution of asymptomatic alumina matrix composite ceramic liner dissociation: a case report.

Authors:  He Xiao; Jian Wang; Nian-Ye Zheng; Zhan-Jun Shi
Journal:  BMC Musculoskelet Disord       Date:  2022-08-20       Impact factor: 2.562

3.  Triboelectric touch sensor for position mapping during total hip arthroplasty.

Authors:  Jae Bum Jeong; Hyeok Kim; Jun-Il Yoo
Journal:  BMC Res Notes       Date:  2020-08-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.