A Aguinaga1, A Navascués, I Polo, C Ezpeleta. 1. Aitziber Aguinaga Pérez, Servicio de Microbiología Clínica. Complejo Hospitalario de Navarra, Calle de Irunlarrea 3, Pamplona, Navarra (CP: 31008). Spain. aitziber.aguinaga.perez@cfnavarra.es.
Abstract
OBJECTIVE: The aim of the study is to compare two confirmatory tests for HIV-1/2 infection. METHODS: A prospective study was carried out between 01/01/2015 and 12/31/2015. Serum samples with repeatedly positive results in the Antibody-Antigen-HIV-1/2 (Architect, Abbott) screening assay were included. The serum samples corresponding to new diagnosed cases were selected and were used to compare the two confirmatory assays: Geenius™ HIV-1/2 (Bio-Rad) and INNO-LIA™ HIV-1/2 score line-immunoassay (Innogene-tics®). The HIV-1 viral load (Cobas® AmpliPrepHIV, Ro-che) was performed in discordant or indeterminate cases. RESULTS: Eight five samples were included. The results of both confirmatory assays were concordant in 80/85 samples: 53 HIV-1, 1 HIV-2, 25 negative and one indeterminate. Cohen's Kappa concordance coefficient between Geenius™ and INNO-LIA™ techniques was very high (0.878). CONCLUSIONS: The concordance between the two assays is high. The procedure for Geenius™ is simple and fast. Geenius™ is a good alternative to include in the HIV-1/2 diagnostic algorithm.
OBJECTIVE: The aim of the study is to compare two confirmatory tests for HIV-1/2 infection. METHODS: A prospective study was carried out between 01/01/2015 and 12/31/2015. Serum samples with repeatedly positive results in the Antibody-Antigen-HIV-1/2 (Architect, Abbott) screening assay were included. The serum samples corresponding to new diagnosed cases were selected and were used to compare the two confirmatory assays: Geenius™ HIV-1/2 (Bio-Rad) and INNO-LIA™ HIV-1/2 score line-immunoassay (Innogene-tics®). The HIV-1 viral load (Cobas® AmpliPrepHIV, Ro-che) was performed in discordant or indeterminate cases. RESULTS: Eight five samples were included. The results of both confirmatory assays were concordant in 80/85 samples: 53 HIV-1, 1 HIV-2, 25 negative and one indeterminate. Cohen's Kappa concordance coefficient between Geenius™ and INNO-LIA™ techniques was very high (0.878). CONCLUSIONS: The concordance between the two assays is high. The procedure for Geenius™ is simple and fast. Geenius™ is a good alternative to include in the HIV-1/2 diagnostic algorithm.
Authors: F Tornero Romero; M L Docavo Barrenechea-Moxó; L Picazo García; M C Santos; J González Del Castillo Journal: Rev Esp Quimioter Date: 2018-03-23 Impact factor: 1.553