Dynamic tracking of prosthetic valve motion and deformation from bi-plane x-ray views: feasibility study.

Charles R Hatt1, Martin Wagner2, Amish N Raval3, Michael A Speidel4.   

Abstract

Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 ± 2.6 mm (mean ± S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm ± 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 ± 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.

Entities:  

Keywords:  2D/3D registration; biplane x-ray; image guidance; interventional cardiology; tracking; valve

Year:  2016        PMID: 28008211      PMCID: PMC5166601          DOI: 10.1117/12.2216588

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  6 in total

1.  Aortic valve prosthesis tracking for transapical aortic valve implantation.

Authors:  M E Karar; D R Merk; C Chalopin; T Walther; V Falk; O Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-16       Impact factor: 2.924

2.  FTRAC--a robust fluoroscope tracking fiducial.

Authors:  Ameet Kumar Jain; Tabish Mustafa; Yu Zhou; Clif Burdette; Gregory S Chirikjian; Gabor Fichtinger
Journal:  Med Phys       Date:  2005-10       Impact factor: 4.071

3.  Wobbled splatting--a fast perspective volume rendering method for simulation of x-ray images from CT.

Authors:  Wolfgang Birkfellner; Rudolf Seemann; Michael Figl; Johann Hummel; Christopher Ede; Peter Homolka; Xinhui Yang; Peter Niederer; Helmar Bergmann
Journal:  Phys Med Biol       Date:  2005-04-13       Impact factor: 3.609

4.  Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and point distribution model.

Authors:  Guoyan Zheng; Miguel A G Ballester; Martin Styner; Lutz-Peter Nolte
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

Review 5.  Transcatheter aortic valve implantation 10-year anniversary: review of current evidence and clinical implications.

Authors:  Philippe Généreux; Stuart J Head; David A Wood; Susheel K Kodali; Mathew R Williams; Jean-Michel Paradis; Marco Spaziano; A Pieter Kappetein; John G Webb; Alain Cribier; Martin B Leon
Journal:  Eur Heart J       Date:  2012-07-31       Impact factor: 29.983

6.  Evaluation of a real-time hybrid three-dimensional echo and X-ray imaging system for guidance of cardiac catheterisation procedures.

Authors:  R J Housden; A Arujuna; Y Ma; N Nijhof; G Gijsbers; R Bullens; M O'Neill; M Cooklin; C A Rinaldi; J Gill; S Kapetanakis; J Hancock; M Thomas; R Razavi; K S Rhode
Journal:  Med Image Comput Comput Assist Interv       Date:  2012
  6 in total
  1 in total

1.  A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

Authors:  Martin G Wagner; Charles R Hatt; David A P Dunkerley; Lindsay E Bodart; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.