Literature DB >> 28005489

MR Neurography of Brachial Plexus at 3.0 T with Robust Fat and Blood Suppression.

Xinzeng Wang1, Crystal Harrison1, Yogesh K Mariappan1, Karthik Gopalakrishnan1, Avneesh Chhabra1, Robert E Lenkinski1, Ananth J Madhuranthakam1.   

Abstract

Purpose To develop and evaluate magnetic resonance (MR) neurography of the brachial plexus with robust fat and blood suppression for increased conspicuity of nerves at 3.0 T in clinically feasible acquisition times. Materials and Methods This prospective study was HIPAA compliant, with institutional review board approval and written informed consent. A low-refocusing-flip-angle three-dimensional (3D) turbo spin-echo (TSE) sequence was modified to acquire both in-phase and out-of-phase echoes, required for chemical shift (Dixon) reconstruction, in the same repetition by using partial echoes combined with modified homodyne reconstruction with phase preservation. This multiecho TSE modified Dixon (mDixon) sequence was optimized by using simulations and phantom studies and in three healthy volunteers. The sequence was tested in five healthy volunteers and was evaluated in 10 patients who had been referred for brachial plexopathy at 3.0 T. The images were evaluated against the current standard of care, images acquired with a 3D TSE short inversion time inversion recovery (STIR) sequence, qualitatively by using the Wilcoxon signed-rank test and quantitatively by using the Friedman two-way analysis of variance, with P < .05 considered to indicate a statistically significant difference. Results Multiecho TSE-mDixon involving partial-echo and homodyne reconstruction with phase preservation achieved uniform fat suppression in half the imaging time compared with multiacquisition TSE-mDixon. Compared with 3D TSE STIR, fat suppression, venous suppression, and nerve visualization were significantly improved (P < .05), while arterial suppression was better but not significantly so (P = .06), with increased apparent signal-to-noise ratio in the dorsal nerve root ganglion and C6 nerve (P < .001) with the multiecho TSE-mDixon sequence. Conclusion The multiecho 3D TSE-mDixon sequence provides robust fat and blood suppression, resulting in increased conspicuity of the nerves, in clinically feasible imaging times and can be used for MR neurography of the brachial plexus at 3.0 T. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2016        PMID: 28005489     DOI: 10.1148/radiol.2016152842

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  13 in total

1.  Improved Brachial Plexus Visualization Using an Adiabatic iMSDE-Prepared STIR 3D TSE.

Authors:  Elisabeth Klupp; Barbara Cervantes; Nico Sollmann; Franziska Treibel; Dominik Weidlich; Thomas Baum; Ernst J Rummeny; Claus Zimmer; Jan S Kirschke; Dimitrios C Karampinos
Journal:  Clin Neuroradiol       Date:  2018-07-23       Impact factor: 3.649

2.  Combine contrast-enhanced 3D T2-weighted short inversion time inversion recovery MR neurography with MR angiography at 1.5 T in the assessment of brachial plexopathy.

Authors:  Zhengdao Xu; Tonghua Zhang; Jianxin Chen; Zongbao Liu; Tao Wang; Yijiang Hu; Jiahui Zhang; Feifei Xue
Journal:  MAGMA       Date:  2020-07-13       Impact factor: 2.310

Review 3.  A review of main anatomical and sonographic features of subcutaneous nerve injuries related to orthopedic surgery.

Authors:  Anne Causeret; Isabelle Ract; Jérémy Jouan; Thierry Dreano; Mickaël Ropars; Raphaël Guillin
Journal:  Skeletal Radiol       Date:  2018-03-16       Impact factor: 2.199

4.  Fat suppression in magnetic resonance imaging of the head and neck region: is the two-point DIXON technique superior to spectral fat suppression?

Authors:  Christina M Wendl; Johannes Eiglsperger; Lena-Marie Dendl; Harald Brodoefel; Karl-Michael Schebesch; Christian Stroszczynski; Claudia Fellner
Journal:  Br J Radiol       Date:  2018-02-23       Impact factor: 3.039

5.  CEST-Dixon for human breast lesion characterization at 3 T: A preliminary study.

Authors:  Shu Zhang; Stephen Seiler; Xinzeng Wang; Ananth J Madhuranthakam; Jochen Keupp; Emily E Knippa; Robert E Lenkinski; Elena Vinogradov
Journal:  Magn Reson Med       Date:  2018-01-10       Impact factor: 4.668

6.  Whole-body MRI for metastatic cancer detection using T2 -weighted imaging with fat and fluid suppression.

Authors:  Xinzeng Wang; Ali Pirasteh; James Brugarolas; Neil M Rofsky; Robert E Lenkinski; Ivan Pedrosa; Ananth J Madhuranthakam
Journal:  Magn Reson Med       Date:  2018-02-14       Impact factor: 4.668

Review 7.  Development of magnetic resonance imaging of brachial plexus neuralgia.

Authors:  Ruhui Xiao; Jiao Chen; Chen Zeng; Xu Feng; Tao Li; Sushant-Kumar Das; Bing Li; Chuan Zhang; Hanfeng Yang
Journal:  Neurol Sci       Date:  2022-01-29       Impact factor: 3.307

8.  Value of High-Resolution MRI in the Diagnosis of Brachial Plexus Injury in Infants and Young Children.

Authors:  Qun Lao; Yuzhu Jia; Kaiyu Zhao; Kun Liu; Jianju Feng
Journal:  Int J Gen Med       Date:  2022-06-18

9.  Magnetic resonance neurography: is it so complicated that it needs a touch of genius?

Authors:  Ankita Aggarwal; Avneesh Chhabra
Journal:  Eur Radiol       Date:  2022-02-01       Impact factor: 5.315

10.  Updates in Musculoskeletal Imaging.

Authors:  Erin C Argentieri; Darryl B Sneag; O Kenechi Nwawka; Hollis G Potter
Journal:  Sports Health       Date:  2018 Jul/Aug       Impact factor: 3.843

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.