Dose-response of EBT3 radiochromic films to proton and carbon ion clinical beams.

Roberta Castriconi1, Mario Ciocca, Alfredo Mirandola, Carla Sini, Sara Broggi, Marco Schwarz, Francesco Fracchiolla, Mária Martišíková, Giulia Aricò, Giovanni Mettivier, Paolo Russo.   

Abstract

We investigated the dose-response of the external beam therapy 3 (EBT3) films for proton and carbon ion clinical beams, in comparison with conventional radiotherapy beams; we also measured the film response along the energy deposition-curve in water. We performed measurements at three hadrontherapy centres by delivering monoenergetic pencil beams (protons: 63-230 MeV; carbon ions: 115-400 MeV/u), at 0.4-20 Gy dose to water, in the plateau of the depth-dose curve. We also irradiated the films to clinical MV-photon and electron beams. We placed the EBT3 films in water along the whole depth-dose curve for 148.8 MeV protons and 398.9 MeV/u carbon ions, in comparison with measurements provided by a plane-parallel ionization chamber. For protons, the response of EBT3 in the plateau of the depth-dose curve is not different from that of photons, within experimental uncertainties. For carbon ions, we observed an energy dependent under-response of EBT3 film, from 16% to 29% with respect to photon beams. Moreover, we observed an under-response in the Bragg peak region of about 10% for 148.8 MeV protons and of about 42% for 398.9 MeV/u carbon ions. For proton and carbon ion clinical beams, an under-response occurs at the Bragg peak. For carbon ions, we also observed an under-response of the EBT3 in the plateau of the depth-dose curve. This effect is the highest at the lowest initial energy of the clinical beams, a phenomenon related to the corresponding higher LET in the film sensitive layer. This behavior should be properly modeled when using EBT3 films for accurate 3D dosimetry.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27997377     DOI: 10.1088/1361-6560/aa5078

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy.

Authors:  Blake R Smith; Mark Pankuch; Daniel E Hyer; Wesley S Culberson
Journal:  Med Phys       Date:  2020-09-09       Impact factor: 4.071

2.  Patient-Specific QA of Spot-Scanning Proton Beams using Radiochromic Film.

Authors:  Maria F Chan; Chin-Cheng Chen; Chengyu Shi; Jingdong Li; Xiaoli Tang; Xiang Li; Dennis Mah
Journal:  Int J Med Phys Clin Eng Radiat Oncol       Date:  2017-05-16

3.  LET dependent response of GafChromic films investigated with MeV ion beams.

Authors:  V Grilj; D J Brenner
Journal:  Phys Med Biol       Date:  2018-12-18       Impact factor: 3.609

4.  Experimental dosimetry of EDR2 films in scanning carbon-ion irradiation.

Authors:  Weiwei Wang; Yu Deng; Zhijie Huang
Journal:  J Appl Clin Med Phys       Date:  2022-05-20       Impact factor: 2.243

5.  Experimental Assessment of Proton Dose Calculation Accuracy in Small-Field Delivery Using a Mevion S250 Proton Therapy System.

Authors:  Kyle D DePew; Salahuddin Ahmad; Hosang Jin
Journal:  J Med Phys       Date:  2018 Oct-Dec

6.  Real-time dosimetry with radiochromic films.

Authors:  Pierluigi Casolaro; Luigi Campajola; Giovanni Breglio; Salvatore Buontempo; Marco Consales; Andrea Cusano; Antonello Cutolo; Francesco Di Capua; Francesco Fienga; Patrizio Vaiano
Journal:  Sci Rep       Date:  2019-03-29       Impact factor: 4.379

7.  Monte Carlo calculation of the mass stopping power of EBT3 and EBT-XD films for protons for energy ranges of 50-400 MeV.

Authors:  Chengyu Shi; Chin-Cheng Chen; Dennis Mah; Maria F Chan
Journal:  Precis Radiat Oncol       Date:  2018-11-19

8.  Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.

Authors:  Fatima Padilla-Cabal; Jose Alejandro Fragoso; Andreas Franz Resch; Dietmar Georg; Hermann Fuchs
Journal:  Med Phys       Date:  2019-11-13       Impact factor: 4.071

9.  Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields.

Authors:  Fatima Padilla-Cabal; Peter Kuess; Dietmar Georg; Hugo Palmans; Lukas Fetty; Hermann Fuchs
Journal:  Med Phys       Date:  2019-05-31       Impact factor: 4.071

10.  Technical note: Vendor-agnostic water phantom for 3D dosimetry of complex fields in particle therapy.

Authors:  Christoph Schuy; Yuri Simeonov; Marco Durante; Klemens Zink; Uli Weber
Journal:  J Appl Clin Med Phys       Date:  2020-09-29       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.