Literature DB >> 27996305

Infection control and patient discomfort with an alternative plastic barrier in intraoral digital radiography.

Arnon Charuakkra1, Sangsom Prapayasatok1, Apirum Janhom1, Karune Verochana1, Phattaranant Mahasantipiya1.   

Abstract

OBJECTIVES: (1) To compare the efficacy of a commercially available hygienic sheath and an alternative plastic bag in preventing contamination of the imaging plate during intraoral radiography and (2) to compare patient discomfort when using the hygienic sheath and the plastic bag.
METHODS: 60 sterilized Size 2 imaging plates covered with either the hygienic sheath (n = 30) or the plastic bag (n = 30) were used to simulate digital periapical radiographic examination in 30 volunteer patients. After disinfection, each plate was swabbed. The swabbed medium was then plated on trypticase soy agar and incubated. Bacterial colonies were counted. Patient discomfort was assessed using a visual analogue scale (VAS) score. The comparison of the number of bacterial colonies and VAS scores between the two groups was tested by paired t-test at p < 0.05.
RESULTS: There was no significant difference in the number of bacterial colonies between the two groups (p = 0.745). Of all the plates, 10% plates yielded bacterial colonies. The mean count of bacterial colonies for both groups was 10-20 CFU ml-1. However, there was a significant difference between VAS scores for the two systems (p = 0.000). The mean VAS scores (range 0-10) for patient discomfort for the hygienic sheath group and the plastic bag group were 3.03 and 5.33, respectively.
CONCLUSIONS: Based on the design of this study, the alternative barrier provided similar results to those commercially available. Regarding the type of barrier envelope, the hygienic sheath induced less discomfort than the plastic bag.

Entities:  

Keywords:  bacterial infections; digital radiography; equipment contamination; infection control

Mesh:

Substances:

Year:  2016        PMID: 27996305      PMCID: PMC5595010          DOI: 10.1259/dmfr.20160253

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  10 in total

1.  Assessing the effectiveness of direct digital radiography barrier sheaths and finger cots.

Authors:  S D Hokett; J R Honey; F Ruiz; M K Baisden; M M Hoen
Journal:  J Am Dent Assoc       Date:  2000-04       Impact factor: 3.634

2.  Infection control for dental radiographic procedures in US dental hygiene programmes.

Authors:  E T Parks; A G Farman
Journal:  Dentomaxillofac Radiol       Date:  1992-02       Impact factor: 2.419

3.  Surface disinfection of saliva-contaminated dental X-ray film packets.

Authors:  G V Packota; K Komiyama
Journal:  J Can Dent Assoc       Date:  1992-09       Impact factor: 1.316

4.  An evaluation of microbiologic contamination on phosphor plates in a dental school.

Authors:  Sajitha Menon Kalathingal; Stephanie Moore; Soon Kwon; George S Schuster; Michael K Shrout; Kevin Plummer
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-07-25

5.  An evaluation of microbiologic contamination on a phosphor plate system: is weekly gas sterilization enough?

Authors:  Sajitha Kalathingal; Alison Youngpeter; Jason Minton; Michael Shrout; Douglas Dickinson; Kevin Plummer; Stephen Looney
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2010-01-08

6.  Infection control in digital intraoral radiography: evaluation of microbiological contamination of photostimulable phosphor plates in barrier envelopes.

Authors:  David S MacDonald; J Douglas Waterfield
Journal:  J Can Dent Assoc       Date:  2011       Impact factor: 1.316

7.  Ethylene oxide's role as a reactive agent during sterilization: effects of polymer composition and device architecture.

Authors:  Edward Phillip; N Sanjeeva Murthy; Durgadas Bolikal; Pallassana Narayanan; Joachim Kohn; Linda Lavelle; Stanko Bodnar; Kurt Pricer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-01-08       Impact factor: 3.368

8.  Cross-contamination of the PSP sensor in a preclinical setting.

Authors:  Wendy Negron; Sally M Mauriello; Charlotte A Peterson; Roland Arnold
Journal:  J Dent Hyg       Date:  2005-07-01

9.  Patient discomfort and cross-infection control in bitewing examination with a storage phosphor plate and a CCD-based sensor.

Authors:  A Wenzel; E Frandsen; H Hintze
Journal:  J Dent       Date:  1999-03       Impact factor: 4.379

10.  Defective plastic infection-control barriers and faulty technique may cause PSP plate contamination used in digital intraoral radiography.

Authors:  Arthur S Kuperstein
Journal:  J Evid Based Dent Pract       Date:  2012-09       Impact factor: 5.267

  10 in total
  3 in total

1.  The assessment of adherence to infection control in oral radiology using newly developed and validated questionnaire (QICOR).

Authors:  Eliana Dantas da Costa; Adriana Dantas da Costa; Carlos Augusto de Souza Lima; Rosana de Fátima Possobon; Glaucia Maria Bovi Ambrosano
Journal:  Dentomaxillofac Radiol       Date:  2018-05-31       Impact factor: 2.419

2.  Factors Affecting Compliance of Infection Control Measures among Dental Radiographers.

Authors:  Maram Alakhras; Dana S Al-Mousa; Arwa Mahasneh; Amani G AlSa'di
Journal:  Int J Dent       Date:  2020-11-16

3.  Turkish adaptation and implementation of the modified infection control questionnaire in intraoral digital imaging.

Authors:  Melih Ozdede; Zuhre Akarslan; Bulent Altunkaynak; Ilkay Peker
Journal:  Eur Oral Res       Date:  2020-09-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.