Literature DB >> 10770008

Assessing the effectiveness of direct digital radiography barrier sheaths and finger cots.

S D Hokett1, J R Honey, F Ruiz, M K Baisden, M M Hoen.   

Abstract

BACKGROUND: Effective cross-contamination prevention is critical for direct digital radiography, or DDR, sensors, which are not sterilizable; however, current manufacturers' recommendations for standard precautions are limited to the use of plastic barrier sheaths, which are commonly known to tear or leak. The authors sought to determine the incidence of digital radiography barrier-sheath leakage, with and without additional latex finger cot protection, as measured by a water pressure test.
METHODS: Four hundred plastic barrier sheaths were randomly assigned to four groups based on intraoral radiograph positioning device use and supplemental barrier protection with a latex finger cot. Sheaths were carefully placed to cover DDR sensors for a single intraoral use, gently removed from the sensors and tested for leakage through a water pressure technique.
RESULTS: Perforations occurred in 44 to 51 percent of plastic sheaths after a single radiographic exposure. However, only up to 6 percent of the plastic sheaths that were covered by a latex finger cot leaked during the water pressure test.
CONCLUSIONS: At least 44 percent of the plastic barrier sheaths leaked after a single intraoral radiographic exposure. Use of a latex finger cot over the plastic sheath significantly reduced leakage to no more than 6 percent. CLINICAL IMPLICATIONS: Latex finger cots used in conjunction with the standard plastic sheaths that cover DDR sensors may more effectively prevent cross-contamination than do plastic sheaths alone. Dentists who use DDR sensors during highly invasive dental procedures such as dental implant surgery are encouraged to consider supplemental barrier protection for these delicate, expensive and nonsterilizable sensors to prevent patient cross-contamination.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10770008     DOI: 10.14219/jada.archive.2000.0202

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  16 in total

1.  Perforation rate of intraoral barriers for direct digital radiography.

Authors:  J-W Choi
Journal:  Dentomaxillofac Radiol       Date:  2014-11-20       Impact factor: 2.419

2.  Creation of a dental X-ray unit with a contactless exposure control switch.

Authors:  M Yoshida; E Honda; M Notsu; N Maeda; H Hosoki
Journal:  Dentomaxillofac Radiol       Date:  2014-02-03       Impact factor: 2.419

3.  Microbial contamination in intraoral phosphor storage plates: the dilemma.

Authors:  Tricia Murielly Pereira Andrade de Souza; Ricardo Dias de Castro; Laís César de Vasconcelos; Andréa Dos Anjos Pontual; Flávia Maria de Moraes Ramos Perez; Maria Luiza Dos Anjos Pontual
Journal:  Clin Oral Investig       Date:  2016-03-16       Impact factor: 3.573

4.  Infection control and patient discomfort with an alternative plastic barrier in intraoral digital radiography.

Authors:  Arnon Charuakkra; Sangsom Prapayasatok; Apirum Janhom; Karune Verochana; Phattaranant Mahasantipiya
Journal:  Dentomaxillofac Radiol       Date:  2016-12-20       Impact factor: 2.419

5.  Antimicrobial efficiency of ethanol and 2-propanol alcohols used on contaminated storage phosphor plates and impact on durability of the plate.

Authors:  A Wenzel; F Kornum; Mr Knudsen; E Frandsen Lau
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

Review 6.  Impact of COVID-19 on Dentistry.

Authors:  Arghavan Tonkaboni; Mohammad Hosein Amirzade-Iranaq; Heliya Ziaei; Amber Ather
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

7.  Dental radiographic procedures during COVID-19 outbreak and normalization period: recommendations on infection control.

Authors:  Betul Ilhan; İbrahim Sevki Bayrakdar; Kaan Orhan
Journal:  Oral Radiol       Date:  2020-06-29       Impact factor: 1.852

Review 8.  Coronavirus Disease 19 (COVID-19): Implications for Clinical Dental Care.

Authors:  Amber Ather; Biraj Patel; Nikita B Ruparel; Anibal Diogenes; Kenneth M Hargreaves
Journal:  J Endod       Date:  2020-04-06       Impact factor: 4.171

9.  Factors Affecting Compliance of Infection Control Measures among Dental Radiographers.

Authors:  Maram Alakhras; Dana S Al-Mousa; Arwa Mahasneh; Amani G AlSa'di
Journal:  Int J Dent       Date:  2020-11-16

Review 10.  Overview of transnational recommendations for COVID-19 transmission control in dental care settings.

Authors:  Mohamed Jamal; Maanas Shah; Sameeha Husain Almarzooqi; Hend Aber; Summayah Khawaja; Rashid El Abed; Zuhair Alkhatib; Lakshman Perera Samaranayake
Journal:  Oral Dis       Date:  2020-06-03       Impact factor: 4.068

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.