| Literature DB >> 27995156 |
Eriko Maeda1, Nobuo Tomizawa2, Shigeaki Kanno1, Koichiro Yasaka1, Takatoshi Kubo1, Kenji Ino3, Rumiko Torigoe4, Kuni Ohtomo1.
Abstract
The data presented in this articles are related to the research article entitled "The feasibility of Forward-projected model-based Iterative Reconstruction SoluTion (FIRST) for coronary 320-row computed tomography angiography: a pilot study" (E. Maeda, N. Tomizawa, S. Kanno, K. Yasaka, T. Kubo, K. Ino, R. Torigoe, K. Ohtomo, 2016) [1]. This article describes subjective and objective evaluations of 2 mm-4 mm coronary artery phantom scanned with 100% dose and reconstructed with hybrid iterative reconstruction, and 90%, 80% and 70% dose reconstructed with full iterative reconstruction.Entities:
Keywords: 320-row CT; Coronary CT angiography; Image quality; Iterative reconstruction; Radiation dose
Year: 2016 PMID: 27995156 PMCID: PMC5154964 DOI: 10.1016/j.dib.2016.11.084
Source DB: PubMed Journal: Data Brief ISSN: 2352-3409
Fig. 1Unenhanced CT image of coronary artery phantom and region-of-interests placed on right upper, left upper, right lower and left lower quadrants.
Data for 3 boards on each sides of the phantom.
| Reconstruction | Initial dose | −10% dose | −20% dose | −30% dose |
|---|---|---|---|---|
| eAIDR | FIRST | FIRST | FIRST | |
| Tube current (mA) | 150 | 140 | 120 | 100 |
| Standard deviation (Hounsfield units) | 16.25 | 16.69 | 17.05 | 16.65 |
| Subjective scores | ||||
| 4 mm phantom | 3 | 4 | 4 | 4 |
| 3 mm phantom | 3 | 3 | 3 | 2 |
| 2 mm phantom | 3 | 4 | 3 | 4 |
Data for 4 boards on each sides of the phantom.
| Reconstruction | Initial dose | −10% dose | −20% dose | −30% dose |
|---|---|---|---|---|
| eAIDR | FIRST | FIRST | FIRST | |
| Tube current (mA) | 200 | 180 | 160 | 140 |
| Standard deviation (Hounsfield units) | 16.67 | 16.44 | 16.37 | 16.62 |
| Subjective scores | ||||
| 4 mm phantom | 3 | 4 | 4 | 5 |
| 3 mm phantom | 3 | 4 | 4 | 4 |
| 2 mm phantom | 3 | 4 | 4 | 4 |
Data for 5 boards on each sides of the phantom.
| Reconstruction | Initial dose | −10% dose | −20% dose | −30% dose |
|---|---|---|---|---|
| eAIDR | FIRST | FIRST | FIRST | |
| Tube current (mA) | 250 | 230 | 200 | 180 |
| Standard deviation (Hounsfield units) | 18.98 | 16 | 16.87 | 16.65 |
| Subjective scores | ||||
| 4 mm phantom | 3 | 4 | 3 | 3 |
| 3 mm phantom | 3 | 3 | 2 | 3 |
| 2 mm phantom | 3 | 4 | 3 | 2 |
Data for 6 boards on each sides of the phantom.
| Reconstruction | Initial dose | −10% dose | −20% dose | −30% dose |
|---|---|---|---|---|
| eAIDR | FIRST | FIRST | FIRST | |
| Tube current (mA) | 350 | 320 | 280 | 250 |
| Standard deviation (Hounsfield units) | 16.82 | 16.33 | 17.28 | 16.48 |
| Subjective scores | ||||
| 4 mm phantom | 3 | 5 | 4 | 4 |
| 3 mm phantom | 3 | 2 | 3 | 3 |
| 2 mm phantom | 3 | 3 | 2 | 2 |
| Subject area | Radiology |
| More specific subject area | Effect dose reduction on image quality in CT images reconstructed with full iterative reconstruction. |
| Type of data | Table, image, text file |
| How data was acquired | Coronary phantoms were scanned with computed tomography at various doses. |
| 100% dose images were reconstructed with hybrid iterative reconstruction, while other dose images were reconstructed with full iterative reconstruction. | |
| Subjective and objective image quality of each images were assessed. | |
| Data format | Raw, Analyzed |
| Experimental factors | The subjective and objective image quality of coronary artery phantom scanned with various dose were evaluated by 3 radiologists. |
| Experimental features | The relationship between the degree of dose reduction and image quality was determined for images reconstructed using Forward-projected model-based Iterative Reconstruction SoluTion (FIRST). |
| Data source location | Hongo, Bunkyo-ku, Tokyo 35° 42′ 45.64″ N; 139° 45′ 43.16″ E |
| Data accessibility | The data are available with this article |