Literature DB >> 27991451

A Monte Carlo study of monoenergetic and polyenergetic normalized glandular dose (DgN) coefficients in mammography.

Antonio Sarno1, Giovanni Mettivier, Francesca Di Lillo, Paolo Russo.   

Abstract

We investigated the influence of model assumptions in GEANT4 Monte Carlo (MC) simulations for the calculation of monoenergetic and polyenergetic normalized glandular dose coefficients (DgN) in mammography, focussing on the effect of the skin thickness and composition, of the role of compression paddles and of the bremsstrahlung processes. We showed that selecting a skin thickness of 4 mm instead of 1.45 mm produced DgN values with deviations from 9% to 32% for x-ray spectra routinely adopted in mammography. Consideration of the bremsstrahlung radiation had a weak influence on monoenergetic DgN. Simulations (in the range 8-40 kVp) which included consideration of bremsstrahlung radiation, a skin thickness of 1.45 mm and a 2 mm thick compression paddles produced polyenergetic DgN coefficients up to 19% higher than corresponding literature data. Adding a 2 mm thick adipose layer between the skin layer and the radiosensitive portion of the breast produces polyenergetic DgN values up to 15% higher than those routinely adopted. These findings provide a quantitative estimate of the influence of model parameters on the calculation of the mean glandular dose in mammography.

Mesh:

Year:  2016        PMID: 27991451     DOI: 10.1088/1361-6560/62/1/306

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

Authors:  Antonio Sarno; David R Dance; Ruben E van Engen; Kenneth C Young; Paolo Russo; Francesca Di Lillo; Giovanni Mettivier; Kristina Bliznakova; Baowei Fei; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2017-06-13       Impact factor: 4.071

2.  Detectability comparison of simulated tumors in digital breast tomosynthesis using high-energy X-ray inline phase sensitive and commercial imaging systems.

Authors:  Muhammad U Ghani; Molly D Wong; Farid H Omoumi; Bin Zheng; Laurie L Fajardo; Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Phys Med       Date:  2018-02-23       Impact factor: 2.685

3.  Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes.

Authors:  Giovanni Mettivier; Antonio Sarno; Youfang Lai; Bruno Golosio; Viviana Fanti; Maria Elena Italiano; Xun Jia; Paolo Russo
Journal:  Cancers (Basel)       Date:  2022-02-17       Impact factor: 6.639

4.  Three-layer heterogeneous mammographic phantoms for Monte Carlo simulation of normalized glandular dose coefficients in mammography.

Authors:  Tien-Yu Chang; Kuan-Jen Lai; Chun-Yuan Tu; Jay Wu
Journal:  Sci Rep       Date:  2020-02-10       Impact factor: 4.379

  4 in total