3D-templated, fully automated microfluidic input/output multiplexer for endocrine tissue culture and secretion sampling.

Xiangpeng Li1, Jessica C Brooks1, Juan Hu1, Katarena I Ford1, Christopher J Easley1.   

Abstract

A fully automated, 16-channel microfluidic input/output multiplexer (μMUX) has been developed for interfacing to primary cells and to improve understanding of the dynamics of endocrine tissue function. The device utilizes pressure driven push-up valves for precise manipulation of nutrient input and hormone output dynamics, allowing time resolved interrogation of the cells. The ability to alternate any of the 16 channels from input to output, and vice versa, provides for high experimental flexibility without the need to alter microchannel designs. 3D-printed interface templates were custom designed to sculpt the above-channel polydimethylsiloxane (PDMS) in microdevices, creating millimeter scale reservoirs and confinement chambers to interface primary murine islets and adipose tissue explants to the μMUX sampling channels. This μMUX device and control system was first programmed for dynamic studies of pancreatic islet function to collect ∼90 minute insulin secretion profiles from groups of ∼10 islets. The automated system was also operated in temporal stimulation and cell imaging mode. Adipose tissue explants were exposed to a temporal mimic of post-prandial insulin and glucose levels, while simultaneous switching between labeled and unlabeled free fatty acid permitted fluorescent imaging of fatty acid uptake dynamics in real time over a ∼2.5 hour period. Application with varying stimulation and sampling modes on multiple murine tissue types highlights the inherent flexibility of this novel, 3D-templated μMUX device. The tissue culture reservoirs and μMUX control components presented herein should be adaptable as individual modules in other microfluidic systems, such as organ-on-a-chip devices, and should be translatable to different tissues such as liver, heart, skeletal muscle, and others.

Entities:  

Mesh:

Year:  2017        PMID: 27990542      PMCID: PMC5293597          DOI: 10.1039/c6lc01201a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  43 in total

1.  Microfluidic large-scale integration.

Authors:  Todd Thorsen; Sebastian J Maerkl; Stephen R Quake
Journal:  Science       Date:  2002-09-26       Impact factor: 47.728

2.  Quantitative measurement of zinc secretion from pancreatic islets with high temporal resolution using droplet-based microfluidics.

Authors:  Christopher J Easley; Jonathan V Rocheleau; W Steven Head; David W Piston
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

3.  High Temporal Resolution Detection of Patient-Specific Glucose Uptake from Human ex Vivo Adipose Tissue On-Chip.

Authors:  Alessandro Zambon; Alice Zoso; Onelia Gagliano; Enrico Magrofuoco; Gian Paolo Fadini; Angelo Avogaro; Mirto Foletto; Stephen Quake; Nicola Elvassore
Journal:  Anal Chem       Date:  2015-06-25       Impact factor: 6.986

4.  Protein quantification using controlled DNA melting transitions in bivalent probe assemblies.

Authors:  Joonyul Kim; Juan Hu; Andresa B Bezerra; Mark D Holtan; Jessica C Brooks; Christopher J Easley
Journal:  Anal Chem       Date:  2015-09-30       Impact factor: 6.986

5.  Microfluidic perifusion and imaging device for multi-parametric islet function assessment.

Authors:  Adeola F Adewola; Dongyoung Lee; Tricia Harvat; Javeed Mohammed; David T Eddington; Jose Oberholzer; Yong Wang
Journal:  Biomed Microdevices       Date:  2010-06       Impact factor: 2.838

Review 6.  The role of added sugars in pediatric obesity.

Authors:  Jean A Welsh; Solveig A Cunningham
Journal:  Pediatr Clin North Am       Date:  2011-12       Impact factor: 3.278

7.  Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay.

Authors:  Michael G Roper; Jonathan G Shackman; Gabriella M Dahlgren; Robert T Kennedy
Journal:  Anal Chem       Date:  2003-09-15       Impact factor: 6.986

8.  Microfluidic device for multimodal characterization of pancreatic islets.

Authors:  Javeed Shaikh Mohammed; Yong Wang; Tricia A Harvat; Jose Oberholzer; David T Eddington
Journal:  Lab Chip       Date:  2008-10-21       Impact factor: 6.799

9.  Quantitative monitoring of insulin secretion from single islets of Langerhans in parallel on a microfluidic chip.

Authors:  John F Dishinger; Kendra R Reid; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-04-15       Impact factor: 6.986

10.  Multiplexed microfluidic enzyme assays for simultaneous detection of lipolysis products from adipocytes.

Authors:  Colleen E Dugan; William P Cawthorn; Ormond A MacDougald; Robert T Kennedy
Journal:  Anal Bioanal Chem       Date:  2014-06-01       Impact factor: 4.142

View more
  20 in total

Review 1.  Progress, obstacles, and limitations in the use of stem cells in organ-on-a-chip models.

Authors:  Alexa Wnorowski; Huaxiao Yang; Joseph C Wu
Journal:  Adv Drug Deliv Rev       Date:  2018-06-06       Impact factor: 15.470

2.  Resealable, optically accessible, PDMS-free fluidic platform for ex vivo interrogation of pancreatic islets.

Authors:  Giovanni Lenguito; Deborah Chaimov; Jonathan R Weitz; Rayner Rodriguez-Diaz; Siddarth A K Rawal; Alejandro Tamayo-Garcia; Alejandro Caicedo; Cherie L Stabler; Peter Buchwald; Ashutosh Agarwal
Journal:  Lab Chip       Date:  2017-02-28       Impact factor: 6.799

3.  Multiplexed drug testing of tumor slices using a microfluidic platform.

Authors:  A Folch; R C Rostomily; L F Horowitz; A D Rodriguez; Z Dereli-Korkut; R Lin; K Castro; A M Mikheev; R J Monnat
Journal:  NPJ Precis Oncol       Date:  2020-05-19

Review 4.  Flat and microstructured polymeric membranes in organs-on-chips.

Authors:  Thijs Pasman; Dirk Grijpma; Dimitrios Stamatialis; Andreas Poot
Journal:  J R Soc Interface       Date:  2018-07       Impact factor: 4.118

5.  micrIO: an open-source autosampler and fraction collector for automated microfluidic input-output.

Authors:  Scott A Longwell; Polly M Fordyce
Journal:  Lab Chip       Date:  2019-11-08       Impact factor: 6.799

6.  Automated microfluidic droplet sampling with integrated, mix-and-read immunoassays to resolve endocrine tissue secretion dynamics.

Authors:  Xiangpeng Li; Juan Hu; Christopher J Easley
Journal:  Lab Chip       Date:  2018-09-26       Impact factor: 6.799

7.  Synchronized stimulation and continuous insulin sensing in a microfluidic human Islet on a Chip designed for scalable manufacturing.

Authors:  Aaron L Glieberman; Benjamin D Pope; John F Zimmerman; Qihan Liu; John P Ferrier; Jennifer H R Kenty; Adrian M Schrell; Nikita Mukhitov; Kevin L Shores; Adrian Buganza Tepole; Douglas A Melton; Michael G Roper; Kevin Kit Parker
Journal:  Lab Chip       Date:  2019-09-10       Impact factor: 6.799

Review 8.  3D printing in cell culture systems and medical applications.

Authors:  Max J Lerman; Josephine Lembong; Greg Gillen; John P Fisher
Journal:  Appl Phys Rev       Date:  2018-12       Impact factor: 19.162

9.  Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.

Authors:  Jean T Negou; L Adriana Avila; Xiangpeng Li; Tesfagebriel M Hagos; Christopher J Easley
Journal:  Anal Chem       Date:  2017-05-11       Impact factor: 6.986

Review 10.  Microfluidic systems for studying dynamic function of adipocytes and adipose tissue.

Authors:  Xiangpeng Li; Christopher J Easley
Journal:  Anal Bioanal Chem       Date:  2017-12-06       Impact factor: 4.142

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.