Assessment of an Aggregate-Level Hand Hygiene Monitoring Technology for Measuring Hand Hygiene Performance Among Healthcare Personnel.

Heather M Limper1, Lynn Slawsky2, Sylvia Garcia-Houchins2, Supriya Mehta3, Ronald C Hershow3, Emily Landon1.   

Abstract

BACKGROUND Despite significant advances in technological methods for hand hygiene surveillance, a lack of evidence prohibits comparison of systems to one another or against the current gold standard of direct observation. OBJECTIVE To validate a hand hygiene monitoring technology (HHMT) designed to capture hand hygiene behaviors aggregated at the hospital-unit level (GOJO Industries, Akron, OH). METHODS Our team followed a rigorous validation approach to assess the sensitivity and positive predictive value (PPV) of an HHMT. A planned path was first used to measure the accuracy of the system when purposefully activated by investigators. Next, behavioral validation was used to quantify accuracy of the system in capturing real-world behaviors. RESULTS During the planned path phase, investigators performed 4,872 unique events across 3 distinct hospital buildings varying in size and age since construction. Overall sensitivity across the medical center was 88.7% with a PPV of 99.2%. During the behavioral validation phase, trained direct observers recorded 5,539 unique events across 3 distinct hospital buildings. Overall sensitivity across the medical center was 92.7% and PPV was 84.4%. CONCLUSION Objective measures of sensitivity and PPV indicate the promise of the benefit of this and other HHMTs to capture basic behaviors associated with hand hygiene. Infect Control Hosp Epidemiol 2017;38:348-352.

Mesh:

Year:  2016        PMID: 27989240     DOI: 10.1017/ice.2016.298

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  3 in total

1.  A standardised approach to validate both the accuracy and precision of electronic hand hygiene monitoring systems is needed.

Authors:  Katie-Rose Cawthorne; Richard Pd Cooke
Journal:  J Infect Prev       Date:  2020-10-14

2.  Assessing the accuracy of a new hand hygiene monitoring device (SmartRub®): from the laboratory to clinical practice.

Authors:  Chloé Guitart; Yves-Alain Robert; Nasim Lotfinejad; Simon Fourquier; Yves Martin; Daniela Pires; Julien Sauser; René Beuchat; Didier Pittet
Journal:  Antimicrob Resist Infect Control       Date:  2021-11-06       Impact factor: 4.887

3.  The impact of COVID-19 pandemic on hand hygiene performance in hospitals.

Authors:  Lori D Moore; Greg Robbins; Jeff Quinn; James W Arbogast
Journal:  Am J Infect Control       Date:  2020-08-18       Impact factor: 2.918