Literature DB >> 27979090

A study on biomimetic immunoassay-capillary electrophoresis method based on molecularly imprinted polymer for determination of trace trichlorfon residue in vegetables.

Jie Li1, Juxiu Lu1, Xuguang Qiao2, Zhixiang Xu3.   

Abstract

Pesticide residue in vegetables is a serious problem that has adverse effects on human health. In our study, we designed and synthesized a molecularly imprinted polymer that can selectively recognize trichlorfon. Using the polymer material as biomimetic antibody, we developed a biomimetic immunoassay-capillary electrophoresis method with improved sensitivity for the detection of trichlorfon. We evaluated the competitive reactions between HRP labeled trichlorfon hapten and free trichlorfon with the biomimetic antibody. Factors that affected the sensitivity of our method were tested in detail. Under optimal conditions, the limit of detection (LOD, IC15) and the sensitivity (IC50) of this method were 0.16mgL-1 and 0.13μgL-1 for trichlorfon. We used this method to determine the trichlorfon spiked in the kidney bean and cucumber samples with recoveries ranging from 78.8% to 103%. We also detected residual trichlorfons in the leek samples, and these results were verified by gas chromatography method.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomimetic immunoassay; Capillary electrophoresis; Gas chromatography; Molecularly imprinted polymer; Trichlorfon

Mesh:

Substances:

Year:  2016        PMID: 27979090     DOI: 10.1016/j.foodchem.2016.11.028

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

Review 1.  A comprehensive review on electrochemical and optical aptasensors for organophosphorus pesticides.

Authors:  Hossein Khosropour; Pramod K Kalambate; Rupali P Kalambate; Khageephun Permpoka; Xiaohong Zhou; George Y Chen; Wanida Laiwattanapaisal
Journal:  Mikrochim Acta       Date:  2022-08-31       Impact factor: 6.408

2.  An Electrochemiluminescence Sensor Based on Nafion/Magnetic Fe₃O₄ Nanocrystals Modified Electrode for the Determination of Bisphenol A in Environmental Water Samples.

Authors:  Jiye Chai; Xinru Yu; Jian Zhao; Aili Sun; Xizhi Shi; Dexiang Li
Journal:  Sensors (Basel)       Date:  2018-08-03       Impact factor: 3.576

3.  Rapid Colorimetric Detection of Cartap Residues by AgNP Sensor with Magnetic Molecularly Imprinted Microspheres as Recognition Elements.

Authors:  Mao Wu; Huiyun Deng; Yajun Fan; Yunchu Hu; Yaping Guo; Lianwu Xie
Journal:  Molecules       Date:  2018-06-14       Impact factor: 4.411

  3 in total