Impact of physiological noise correction on detecting blood oxygenation level-dependent contrast in the breast.

Tess E Wallace1, Roido Manavaki, Martin J Graves, Andrew J Patterson, Fiona J Gilbert.   

Abstract

Physiological fluctuations are expected to be a dominant source of noise in blood oxygenation level-dependent (BOLD) magnetic resonance imaging (MRI) experiments to assess tumour oxygenation and angiogenesis. This work investigates the impact of various physiological noise regressors: retrospective image correction (RETROICOR), heart rate (HR) and respiratory volume per unit time (RVT), on signal variance and the detection of BOLD contrast in the breast in response to a modulated respiratory stimulus. BOLD MRI was performed at 3 T in ten volunteers at rest and during cycles of oxygen and carbogen gas breathing. RETROICOR was optimized using F-tests to determine which cardiac and respiratory phase terms accounted for a significant amount of signal variance. A nested regression analysis was performed to assess the effect of RETROICOR, HR and RVT on the model fit residuals, temporal signal-to-noise ratio, and BOLD activation parameters. The optimized RETROICOR model accounted for the largest amount of signal variance ([Formula: see text]  =  3.3  ±  2.1%) and improved the detection of BOLD activation (P  =  0.002). Inclusion of HR and RVT regressors explained additional signal variance, but had a negative impact on activation parameter estimation (P  <  0.001). Fluctuations in HR and RVT appeared to be correlated with the stimulus and may contribute to apparent BOLD signal reactivity.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27973353      PMCID: PMC6050521          DOI: 10.1088/1361-6560/62/1/127

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


Introduction

Blood oxygenation level-dependent (BOLD) contrast exploits the differential magnetic properties of oxygenated and deoxygenated haemoglobin to enable detection of changes in blood oxygenation and flow. BOLD contrast is extensively used in functional magnetic resonance imaging (fMRI) experiments to map brain activation in response to a stimulus or to depict resting-state functional connectivity. As BOLD signal changes are small, they require a high temporal signal-to-noise ratio (TSNR) for reliable detection (Murphy et al 2007). Imaging at higher static magnetic field strengths (B0) increases SNR and hence TSNR; however, the relative contribution of physiological noise also increases with field strength, thereby decreasing signal detection power (Kruger and Glover 2001). Several sources of physiological noise have been identified in the fMRI literature, including those associated with cardiac (Dagli et al 1999, Shmueli et al 2007) and respiratory (Wise et al 2004, Birn et al 2006) processes, and residual movement artefacts after registration (Lund et al 2005). There is growing interest in applying BOLD contrast outside of the brain to assess tumour oxygenation and angiogenesis via vasomotor response to modulated hyperoxic and hypercapnic gas stimuli. These experiments are analogous to fMRI of the brain, with the exception that a respiratory stimulus is needed to directly modulate blood oxygenation and flow. BOLD MRI has been used to demonstrate improved oxygenation in response to inhalation of 100% oxygen or carbogen (2–5% CO2; 95–98% O2) in a variety of solid tumour types, including breast cancer, to derive potential markers of tumour hypoxia (Griffiths et al 1997, Taylor et al 2001, Rijpkema et al 2002, Alonzi et al 2009, Jiang et al 2013). A pilot study in breast cancer patients undergoing neoadjuvant chemotherapy (n  =  7) demonstrated that oxygen-induced BOLD contrast changes were significantly greater (P  <  0.001) in patients exhibiting a complete pathological response versus those exhibiting partial response or stable disease (Jiang et al 2013). These studies suggest that BOLD MRI may aid patient stratification for hypoxia-targeted therapies and has potential to provide early predictive response monitoring. Other studies in the breast have shown that 100% oxygen interleaved with carbogen (5% CO2, 95% O2) in a block design is the optimal stimulus for inducing BOLD contrast (Rakow-Penner et al 2010, Wallace et al 2016a). Carbon dioxide is a potent vasodilator and the opposing effects of these two gases on vascular tone provide a mechanism for BOLD contrast, which is also sensitive to changes in blood volume and flow. In theory, healthy vasculature will constrict and dilate in response to vasoactive stimuli, but immature tumour vessels lacking appropriate smooth muscle vasculature will be unable to respond. Several studies in preclinical tumour models have demonstrated the potential of BOLD contrast as a functional biomarker of vascular maturity (Neeman et al 2001, Gilad et al 2005) and this approach has been successfully translated to derive a functional vascular maturation index in human brain tumours (Ben Bashat et al 2012). However, optical imaging studies have suggested that in a clinical setting physiological fluctuations may confound measurement of haemodynamic response (Carpenter et al 2010a, 2010b). Respiration leads to both motion artefacts and modulation of the magnetic field, and is expected to be a particularly significant source of noise, depending on the target site. In general, background physiological variations and motion increase signal variance, and may even give rise to false-positive activation effects if they happen to be correlated with the stimulus. Various methods for reducing physiological noise have been proposed, operating both in k-space (Hu et al 1995, Le and Hu 1996, Wowk et al 1997) and image space (Glover et al 2000, Deckers et al 2006). Many correction schemes require acquisition of additional physiological data using peripheral measures of cardiac and respiratory function (Hu et al 1995, Glover et al 2000), whilst a few methods utilize the MRI data itself to estimate noise parameters (Le and Hu 1996, Wowk et al 1997). Most physiological noise models can be included as nuisance variables in a general linear model (GLM) regression analysis (Lund et al 2006, Shmueli et al 2007, Kong et al 2012), although some may be used for straightforward data correction (Glover et al 2000). RETROICOR is an established retrospective image-based correction method, which is frequently applied in brain fMRI experiments to improve the statistical significance of activation signals. RETROICOR models cardiac and respiratory fluctuations using a Fourier series defined by the phase of the cardiac and respiratory cycles, relative to the time of image acquisition. The standard RETROICOR implementation, optimized for the cerebrum, comprises two respiratory and two cardiac harmonics (Glover et al 2000). Harvey et al (2008) implemented a modified version of the RETROICOR algorithm to include higher order and multiplicative terms to account for the interaction between cardiac and respiratory signals. The optimized RETROICOR model significantly reduced signal variability in the brainstem and improved detection of activation in response to a finger-tapping task (Harvey et al 2008). As well as quasi-periodic physiological fluctuations, low frequency (<0.1 Hz) variations related to respiratory depth and rate have previously been correlated with changes in BOLD signal intensity. Studies have shown that subtle fluctuations in respiratory volume per unit time (RVT) can account for a significant amount of variance in the resting-state BOLD signal (Wise et al 2004, Birn et al 2006). Shmueli et al (2007) additionally found significant correlations between heart rate (HR) and BOLD signal time courses. The authors demonstrated that including delayed HR time series regressors in a GLM was able to explain an additional 1% of BOLD signal variance, beyond that explained by RVT and RETROICOR regressors (Shmueli et al 2007). Both cardiac (Chang et al 2009) and respiratory (Birn et al 2006) response functions have been proposed in the brain fMRI literature to model these physiological noise effects. Decreasing signal variance should theoretically improve BOLD sensitivity. Hutton et al (2011) found that applying a combination of physiological noise correction models, including HR and RVT regressors, resulted in a 50–70% increase in TSNR, which translated to a 10% increase in the number of significantly activated voxels in fMRI (Hutton et al 2011). The impact of these physiological correction techniques on BOLD signal variance and sensitivity has been investigated in the fMRI literature; however, their use outside the brain has been limited. Cardiac and respiratory fluctuations, including low frequency variations in respiratory volume and heart rate, are expected to influence BOLD sensitivity and parameter estimation. The purpose of this work was to identify and remove variance in the BOLD signal attributed to physiological noise sources in order to improve detection of vascular reactivity to CO2. We sought to optimize the RETROICOR algorithm to account for the maximum amount of signal variance, without over-fitting to noise. We also assessed the impact of the optimized RETROICOR algorithm and regression of HR and RVT on the detection of haemodynamic response via BOLD contrast in the breast, both at rest and in response to a modulated respiratory stimulus paradigm.

Methods

Subjects and stimulus design

MRI data was collected from ten healthy female volunteers aged between 22 and 37 years (median age 27 years). All participants provided written informed consent prior to enrolment in the study, which was approved by the local Research Ethics Committee (REC: 14/EE/0145). Resting state data was acquired as subjects breathed medical air for 12 min. The respiratory gas stimulus paradigm consisted of breathing carbogen interleaved with 100% oxygen in 2 min blocks, for a total of 16 min, as illustrated in figure 1. Medical gases were administered to the subject via an OxyMask™ (Southmedic Inc., Barrie, ON) at a flow rate of 14 l min−1, with automated switching controlled by an in-house gas delivery system.
Figure 1.

Schematic showing the modulated gas fMRI stimulus design. Oxygen and carbogen are cycled in 2 min blocks for a total of 16 min. An example BOLD signal intensity time course extracted from the fibroglandular tissue in a representative volunteer is shown, with the sinusoidal model used to fit the signal intensity response (phase shifted to match the time lag of response and scaled to the amplitude of response) overlaid in red.

Schematic showing the modulated gas fMRI stimulus design. Oxygen and carbogen are cycled in 2 min blocks for a total of 16 min. An example BOLD signal intensity time course extracted from the fibroglandular tissue in a representative volunteer is shown, with the sinusoidal model used to fit the signal intensity response (phase shifted to match the time lag of response and scaled to the amplitude of response) overlaid in red.

Data acquisition

MR imaging was performed at 3 T (MR750, GE Healthcare, Waukesha, WI) using an eight-channel phased-array breast coil with whole body radiofrequency excitation. An in-house developed multi-phase single-shot fast spin echo sequence was used to acquire dynamic T2-weighted images at a single sagittal slice location. A T2-weighted spin-echo based sequence was used for BOLD contrast generation, rather than the more conventional -weighted gradient echo imaging, due to the adverse B0 field distortions created by the breast geometry at higher field strengths (Rakow-Penner et al 2010). Scan parameters were as follows: TR  =  4000 ms, effective TE  =  58 ms, ±83 kHz receiver bandwidth, 128 phase and frequency encoding steps, 20 cm field of view, 5 mm slice thickness and chemical shift selective fat suppression. A total of 180 and 240 images were acquired for the resting-state and oxygen-carbogen datasets respectively, with an in-plane spatial resolution of 1.56  ×  1.56 mm. A high-resolution T1-weighted image was acquired at the same sagittal slice location to provide anatomical detail. Heart rate and respiration were monitored using the scanner’s built-in photoplethysmograph placed on the subject’s index finger and a pneumatic respiratory belt positioned around the abdomen. The cardiac pulse signal and respiratory waveform were sampled at 40 Hz and 10 Hz respectively, and recording was triggered by the start of the scan acquisition. Timing data for each slice acquisition was written to a file to allow retrospective synchronization of the physiological signals with the MRI data.

Image registration and data pre-processing

Each image series was registered using a non-rigid symmetric diffeomorphic normalization (SyN) based algorithm (Advanced Normalization Tools, Philadelphia, PA) to compensate for patient motion during the MR acquisition (Avants et al 2011). Mutual information was used as the similarity metric and all phases were registered to the mean of the time series. A constrained cost-function masking approach was used to localize the motion correction to the breast region. The non-rigid registration was initialized with an affine transform to account for any global motion in the breast. A multi-resolution framework (four resolution levels) was used for both the affine and SyN registration. All subsequent data processing was performed using in-house software developed in Matlab version 8.6 (The Mathworks, Natick, MA). For the scans where subjects breathed the oxygen-carbogen stimulus, imaging data from the first alternating gas period (i.e. first 60 time points) was discarded to allow equilibration of the gas inhalation regime. A region of interest (ROI) was manually drawn to exclude fat in the outer border of the breast, and subsequent analysis was performed pixel-wise within this fibroglandular tissue ROI in each volunteer. A second order polynomial regressor was constructed by fitting linear and quadratic functions to the signal intensity-time course for each pixel to model low frequency temporal drifts, nominally attributed to the scanner hardware.

Physiological noise regression models

The registered datasets were corrected for cardiac pulsatility and respiratory motion artefacts using a modified version of the RETROICOR algorithm. F-test regression analysis was performed to compare models with different combinations of cardiac (C), respiratory (R) and multiplicative (X) terms to find the combination that most effectively reduced BOLD signal variability without over-fitting to noise. The construction and optimization of the RETROICOR model is described in detail in the appendix. Low frequency changes in respiratory volume per unit time (RVT) and heart rate (HR) were modelled using previously published methods (Birn et al 2006, Shmueli et al 2007) (see appendix). The HR and RVT regressors were created by shifting the HR and RVT time courses relative to the imaging data, based on the time lag that resulted in the maximum correlation between HR and RVT and the BOLD signal in each pixel (Birn et al 2006). The temporal cross correlation was calculated pixel-wise over the range  ±1 min (±15 TR), which yielded normalized correlation coefficients for each temporal shift of HR and RVT, relative to the BOLD signal. The mean and standard deviation of HR and RVT, as well as the correlations between the two time courses (within  ±1 min), were calculated for each subject at rest and during cycling of oxygen and carbogen. Fourier power spectra of the HR and RVT time courses were also computed for each subject both at resting-state and for the respiratory stimulus.

Model evaluation

To evaluate the effect of different physiological noise models, a nested regression analysis was performed using the GLM framework in Matlab. Five models were defined as follows: (1) HW, (2) HW  +  CRX, (3) HW  +  CRX  +  HR, (4) HW  +  CRX  +  RVT, (5) HW  +  CRX  +  HR  +  RVT, where HW is the second order polynomial regressor constructed to account for low frequency hardware drifts, CRX represents the optimized RETROICOR regressor combination, and HR and RVT regressors are computed as outlined above. The regressors were fitted to the registered image data (following mean correction) using a GLM and correction was performed by subtracting the fitted effect from the BOLD signal. The adjusted coefficient of determination () was calculated as a measure of the proportion of variance accounted for by each of the models, normalized by the number of regressors. The regression models were chosen such that the explanatory power of each individual correction could be determined by comparing the results of different models. Pixel-wise values were calculated by subtraction of different models as a measure of the additional variance accounted for by each set of regressors. For example, comparing Models 1 and 2 () gives an indication of how much additional variance is explained by the RETROICOR regressors (CRX) alone. Maps of and were created for each subject and values were averaged within the fibroglandular tissue ROI and across subjects. We also investigated the impact of each of the physiological noise models on the TSNR of the imaging data. TSNR was calculated as the mean of each pixel divided by the standard deviation of the time course. Maps of TSNR and percentage improvement in TSNR were created for each subject and the mean TSNR and ΔTSNR (%) were calculated within the fibroglandular tissue ROI and averaged across subjects. No spatial smoothing was applied to the datasets in this analysis, consistent with previous investigations of the impact of physiological noise regressors on and TSNR (Kruger and Glover 2001, Hutton et al 2011).

Impact on BOLD parameter estimation

Prior to functional parameter estimation, both the resting-state and oxygen-carbogen datasets were smoothed using a Gaussian kernel (full width half maximum 4 mm), as spatial filtering is a commonly employed pre-processing step in these types of analyses (Wise et al 2004, Harvey et al 2008, Hutton et al 2011). The linear correlation coefficient between each pixel’s signal intensity-time course and sine and cosine functions at the stimulus frequency (0.0042 Hz) was calculated as a measure of the magnitude of the BOLD response, as described by Lee et al (1995). A sinusoidal waveform was chosen to model the block design stimulus as the haemodynamic response function effectively acts as a temporal low pass filter on the time series (Bulte et al 2006). The cosine function accounts for unknown delays in response. The magnitude of the maximum correlation coefficient and the temporal phase lag at which it occurs are given by the following expressions: where rs and rc are the linear correlation coefficients between the BOLD signal intensity response and the sine and cosine waveforms, rm ranges from 0 to 1 and θr ranges from 0 to 2π. This cross-correlation analysis with the stimulus was performed following each model correction (i.e. subtraction of the fitted regressors from the BOLD signal time course). The same analysis was carried out for the resting-state data, even though there was no imposed stimulus periodicity, to determine the impact of each model correction on the extent of false-positive activation effects. Significantly activated pixels were defined using an uncorrected p-value threshold of less than 0.05 (rm  >  0.14) and the percentage of activated pixels within the fibroglandular tissue ROI was calculated for each subject during rest and activation. The median rm was also calculated over all pixels within the fibroglandular tissue ROI to allow unbiased comparison of oxygen-carbogen and resting-state data.

Statistical analysis

Two-tailed, paired (across subjects) Student’s t-tests were performed to assess the impact of each correction on the TSNR, median correlation coefficient (rm) and percentage of activated pixels in resting-state scans. Paired t-tests were also performed to assess the effect of each correction on the median rm and percentage of activated pixels in response to the vasoactive stimulus, relative to air-only breathing.

Results

Low frequency HR and RVT fluctuations

Summary statistics for HR and RVT, and the correlation between these two physiological time courses, are shown for each subject in table 1. One subject was excluded, due to failure to record a reliable physiological trace. The mean HR across all subjects was 70.2  ±  3.1 beats min−1 (bpm) during air-only breathing and 68.8  ±  4.3 bpm during cycling of oxygen and carbogen gas. RVT fluctuated about 8.2  ±  1.6% at rest and about 9.2  ±  1.6% during oxygen-carbogen breathing. Resting-state HR and RVT were moderately correlated (R  =  −0.323 to 0.403), and the strength of the correlation increased for interleaved oxygen and carbogen breathing in some subjects (R  =  −0.290 to 0.650). Figure 2 shows the Fourier power spectra of HR and RVT both at rest and during the modulated respiratory stimulus. This confirms that fluctuations in heart rate and respiration occur in the low (<0.1 Hz) frequency range. Both HR and RVT spectra exhibited a peak at the stimulus frequency (0.0042 Hz) during oxygen-carbogen breathing, suggesting they are correlated with the stimulus paradigm.
Table 1.

Mean and standard deviation (SD) of measured heart rate (HR) and respiratory volume per unit time (RVT) in each subject and the maximum cross correlation coefficient (CC) between HR and RVT for both air-only and modulated oxygen-carbogen breathing.

Air-onlyOxygen-carbogen
SubjectHRa (bpm)RVTbCCcHR (bpm)RVTCC
175.1  ±  1.7 5.7  ±  0.9−0.32370.9  ±  2.1 6.9  ±  1.20.508
270.1  ±  2.8 5.7  ±  0.70.31662.3  ±  2.1 5.6  ±  0.8−0.246
357.6  ±  6.011.1  ±  1.7−0.25159.0  ±  7.611.4  ±  1.4−0.283
459.3  ±  3.1 9.5  ±  1.90.21958.7  ±  2.910.4  ±  1.80.243
586.2  ±  3.011.5  ±  2.1−0.20786.3  ±  12.210.8  ±  1.5−0.151
677.9  ±  3.1 6.8  ±  1.5−0.17679.0  ±  3.3 8.6  ±  1.4−0.290
774.2  ±  3.1 9.2  ±  1.20.24674.8  ±  3.111.1  ±  1.40.276
869.8  ±  2.2 6.8  ±  2.60.32867.4  ±  2.6 9.7  ±  2.90.650
960.7  ±  2.7 7.4  ±  1.50.40361.0  ±  3.1 9.0  ±  2.20.624
Mean70.2  ±  3.1 8.2  ±  1.668.8  ±  4.3 9.2  ±  1.6
SD 9.5  ±  1.2 2.2  ±  0.6 9.7  ±  3.4 2.0  ±  0.6

Heart rate.

Respiratory volume (in percent) per unit time (s).

Maximum correlation coefficient.

Figure 2.

Fourier power spectra of HR and RVT time courses during (a) and (b) air-only breathing and (c) and (d) oxygen-carbogen breathing averaged over all subjects. The red dashed line denotes the stimulus frequency (0.0042 Hz).

Mean and standard deviation (SD) of measured heart rate (HR) and respiratory volume per unit time (RVT) in each subject and the maximum cross correlation coefficient (CC) between HR and RVT for both air-only and modulated oxygen-carbogen breathing. Heart rate. Respiratory volume (in percent) per unit time (s). Maximum correlation coefficient. Fourier power spectra of HR and RVT time courses during (a) and (b) air-only breathing and (c) and (d) oxygen-carbogen breathing averaged over all subjects. The red dashed line denotes the stimulus frequency (0.0042 Hz).

Optimization of RETROICOR

F-test results in table 2 show the percentage of all pixels in which each test model accounted for significantly more variance than the base model containing a subset of its regressors. Numbers in bold correspond to values above the percentage of pixels set by a binomial (null) threshold. The first order respiratory regressor (1R) accounted for the largest amount of noise, explaining a significant amount of BOLD signal variance in over 30% of pixels. Addition of the second order respiratory regressor (2R) and a single multiplicative term (11X) accounted for a small, but significant, additional amount of variance. Addition of cardiac terms and higher order respiratory and multiplicative regressors did not reduce BOLD signal variance by a significant amount. The optimized RETROICOR model (‘2R11X’) was used in the subsequent nested regression model analysis.
Table 2.

F-test results showing the percentage of pixels within the fibroglandular tissue ROI where variance was significantly reduced by adding specific regressors, relative to the base model, averaged across subjects. Numbers in bold correspond to a significant percentage of pixels above a threshold set by the binomial (null) distribution (corresponding to a 0.01 false-positive rate). The optimal model for reducing variability in the BOLD signal is ‘2R11X’.

RegressorsTest modelBase model% pixels
1Ca1C 1.1
1Rb1R30.7
2C2C1R1C1R 1.0
2R1C2R1C1R1.5
3C3C2R2C2R 0.7
3R2C3R2C2R 1.0
4C4C3R3C3R 1.2
4R3C4R3C3R 1.0
5C5C4R4C4R 0.8
5R4C5R4C4R 0.9
11Xc2C2R11X2C2R1.9
21X2C2R21X2C2R11X 1.3
12X2C2R12X2C2R11X 0.9
22X2C2R22X2C2R12X 1.0

1C: first order cardiac term (calculated according to equation (A.3) with A  =  1 and B  =  0).

1R: first order respiratory term (calculated according to equation (A.3) with A  =  0 and B  =  1).

11X: first order multiplicative term (calculated according to equation (A.4) with C  =  1 and D  =  1).

F-test results showing the percentage of pixels within the fibroglandular tissue ROI where variance was significantly reduced by adding specific regressors, relative to the base model, averaged across subjects. Numbers in bold correspond to a significant percentage of pixels above a threshold set by the binomial (null) distribution (corresponding to a 0.01 false-positive rate). The optimal model for reducing variability in the BOLD signal is ‘2R11X’. 1C: first order cardiac term (calculated according to equation (A.3) with A  =  1 and B  =  0). 1R: first order respiratory term (calculated according to equation (A.3) with A  =  0 and B  =  1). 11X: first order multiplicative term (calculated according to equation (A.4) with C  =  1 and D  =  1).

Impact of physiological corrections on signal variance

The impact of SyN-based non-rigid registration and the five physiological noise regression models on signal variance and image TSNR is summarized in table 3. A significant (P  <  0.001) increase (23.4%) in the mean TSNR of resting-state data was seen post-registration (comparing Models 0 and 1). The model comparison demonstrates the impact of each individual regressor in explaining additional variance, calculated pixel-wise within the ROI. After correction for low-frequency drifts attributed to hardware, adding the three optimal RETROICOR regressors (Model 2) accounted for the largest amount of additional variance in the resting-state BOLD signal (  =  3.3  ±  2.1%). Adding the measured HR and RVT regressors to Model 2 explained similar amounts of variance (2.0  ±  0.6% and 2.3  ±  0.3% respectively). The continued increase in mean demonstrates that each of the regressors were useful in explaining additional variance in the data, up to a maximum of 16.4  ±  3.1% for Model 5. Corresponding significant increases (P  <  0.001) in the mean TSNR were also observed within the fibroglandular tissue ROI for each additional regressor, illustrated in figure 3 for a representative subject. Consistent with the variance analysis, RETROICOR had the largest impact on TSNR, increasing pixel-wise ΔTSNR by an average of 4.4  ±  1.4% across all subjects. ΔTSNR increased to 7.6  ±  1.5% when all physiological regressors were added to the model.
Table 3.

Mean adjusted coefficient of determination () and temporal signal-to-noise ratio (TSNR) of the resting-state BOLD signal within the fibroglandular tissue ROI, averaged across subjects for unregistered data and five nested regression models. Mean difference in voxel-wise and ΔTSNR (%) for each model comparison shows the effect of each correction. The optimized RETROICOR model (denoted CRX) accounts for the largest amount of signal variance (highest and %ΔTSNR).

ModelSyNaRegressorsMean \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}$R_{\text{adj}}^{2}$ \end{document}Radj2Mean TSNRModel comparisonMean \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} }{}$ \Delta R_{\text{adj}}^{2}$ \end{document}ΔRadj2Mean ΔTSNR (%)
HWbCRXcHRdRVTe
X0.156  ±  0.11435.0  ±  8.4
1XX0.091  ±  0.04743.2  ±  10.8
2XXX0.123  ±  0.03544.9  ±  11.02-10.033  ±  0.0214.4  ±  1.4
3XXXX0.144  ±  0.03145.6  ±  11.13-20.020  ±  0.0061.5  ±  0.3
4XXXX0.146  ±  0.03445.6  ±  11.24-20.023  ±  0.0031.6  ±  0.2
5XXXXX0.164  ±  0.03146.2  ±  11.35-10.073  ±  0.0247.6  ±  1.5

Symmetric diffeomorphic normalization based non-rigid registration algorithm.

Hardware (second order polynomial) regressor.

Optimized RETROICOR model.

Heart rate regressor.

Respiratory volume per unit time regressor.

Figure 3.

Maps showing successive differences in the adjusted coefficient of determination () between regression models and corresponding percentage difference in temporal signal-to-noise ratio (TSNR) of resting-state BOLD data, illustrating the importance of each set of physiological noise regressors in a representative volunteer. Maps are overlaid on an anatomical image with scaled between 0 and 0.2 and ΔTSNR scaled between  −20% and  +20%. The optimized RETROICOR model (denoted CRX) accounts for the largest amount of signal variance, corresponding to the brightest map for a single physiological noise model.

Mean adjusted coefficient of determination () and temporal signal-to-noise ratio (TSNR) of the resting-state BOLD signal within the fibroglandular tissue ROI, averaged across subjects for unregistered data and five nested regression models. Mean difference in voxel-wise and ΔTSNR (%) for each model comparison shows the effect of each correction. The optimized RETROICOR model (denoted CRX) accounts for the largest amount of signal variance (highest and %ΔTSNR). Symmetric diffeomorphic normalization based non-rigid registration algorithm. Hardware (second order polynomial) regressor. Optimized RETROICOR model. Heart rate regressor. Respiratory volume per unit time regressor. Maps showing successive differences in the adjusted coefficient of determination () between regression models and corresponding percentage difference in temporal signal-to-noise ratio (TSNR) of resting-state BOLD data, illustrating the importance of each set of physiological noise regressors in a representative volunteer. Maps are overlaid on an anatomical image with scaled between 0 and 0.2 and ΔTSNR scaled between  −20% and  +20%. The optimized RETROICOR model (denoted CRX) accounts for the largest amount of signal variance, corresponding to the brightest map for a single physiological noise model. The SyN-based registration took approximately 6 min to align 180 images (using parallelization with four cores), whilst computational times for the GLM ranged from approximately 1 min (Model 1)–6.5 min (Model 5).

Impact of physiological corrections on BOLD parameter estimation

Non-rigid registration led to a significant reduction in the median correlation coefficient (P  =  0.033) and number of activated pixels (P  =  0.027) for resting-state data. The median correlation coefficient and area of activation also significantly decreased (P  =  0.003 and P  <  0.001) for the vasomotor stimulus. Overall, there was a significant difference in the median correlation coefficient and number of activated pixels between the resting-state and activated scans before any correction was applied (P  =  0.020 and P  =  0.015), which was improved after registration (P  =  0.012 and P  =  0.009). This difference was further improved by subtracting the three optimal RETROICOR regressors (‘2R11X’) from the registered data (P  =  0.002 and P  =  0.002). Although regression of HR and RVT improved the TSNR of resting-state scans and significantly reduced the number of false-positive activations during air-only breathing (P  =  0.038, comparing Model 5 and Model 2), it also significantly reduced the median correlation coefficient and number of activated pixels (P  <  0.001) for the oxygen-carbogen stimulus paradigm, yielding no significant difference between resting-state and activated scans for Models 3–5. These results are summarized in table 4 and the impact of these corrections on detecting activation is illustrated in figure 4 for a representative subject. The median correlation coefficient for resting-state and oxygen-carbogen data is shown for all subjects and correction models in figure 5.
Table 4.

Median correlation coefficient (CC) and percentage of activated pixels (rm  >  0.14) within the fibroglandular tissue ROI and statistical inferences comparing the oxygen-carbogen stimulus to resting-state (air-only) data, averaged across subjects for unregistered data and five physiological noise regression models.

ModelSyNRegressorsAir-onlyOxygen-carbogen
HWCRXHRRVTMedian CCActivation (%)Median CC (P-value)Activation (%) (P-value)
X0.133  ±  0.04639.3  ±  22.40.181  ±  0.047 (0.020)a59.6  ±  13.5 (0.015)a
1XX0.108  ±  0.02527.4  ±  14.80.137  ±  0.020 (0.012)a44.6  ±  9.8 (0.009)a
2XXX0.103  ±  0.01324.5  ±  8.90.133  ±  0.016 (0.002)b42.0  ±  9.3 (0.002)b
3XXXX0.100  ±  0.01623.2  ±  9.70.113  ±  0.012 (0.052)31.6  ±  7.9 (0.038)a
4XXXX0.100  ±  0.01722.6  ±  10.60.104  ±  0.028 (0.702)26.1  ±  16.7 (0.625)
5XXXXX0.098  ±  0.01821.7  ±  11.00.092  ±  0.022 (0.594)20.2  ±  12.7 (0.790)

Significant P  <  0.05.

Highly significant P  <  0.005.

Figure 4.

Activation maps showing magnitude of correlation coefficients (P  <  0.05) for a representative volunteer, illustrating the impact of physiological corrections on the detection of BOLD activation effects for air-only and oxygen-carbogen data. Maps are shown for the same subject as in figure 3. In this volunteer, SyN-based non-rigid registration reduced activation in both air-only and oxygen-carbogen states, addition of the optimized RETROICOR regressors (Model 2) removed false positive activations in the air-only state, whilst addition of HR and RVT regressors had a negative impact on activation detection during oxygen-carbogen gas breathing.

Figure 5.

Boxplot showing the impact of SyN-based non-rigid registration and the five nested physiological noise models on the median correlation coefficient of air-only (resting-state) and oxygen-carbogen data. Over all volunteers, Model 2 (SyN  +  HW  +  CRX) yielded the most highly significant difference between air-only and oxygen-carbogen states.

Median correlation coefficient (CC) and percentage of activated pixels (rm  >  0.14) within the fibroglandular tissue ROI and statistical inferences comparing the oxygen-carbogen stimulus to resting-state (air-only) data, averaged across subjects for unregistered data and five physiological noise regression models. Significant P  <  0.05. Highly significant P  <  0.005. Activation maps showing magnitude of correlation coefficients (P  <  0.05) for a representative volunteer, illustrating the impact of physiological corrections on the detection of BOLD activation effects for air-only and oxygen-carbogen data. Maps are shown for the same subject as in figure 3. In this volunteer, SyN-based non-rigid registration reduced activation in both air-only and oxygen-carbogen states, addition of the optimized RETROICOR regressors (Model 2) removed false positive activations in the air-only state, whilst addition of HR and RVT regressors had a negative impact on activation detection during oxygen-carbogen gas breathing. Boxplot showing the impact of SyN-based non-rigid registration and the five nested physiological noise models on the median correlation coefficient of air-only (resting-state) and oxygen-carbogen data. Over all volunteers, Model 2 (SyN  +  HW  +  CRX) yielded the most highly significant difference between air-only and oxygen-carbogen states.

Discussion

Signal intensity changes induced by the modulated gas stimuli are small, on the order of 1–2%, and the TSNR of the time series is critical to reliably detect vasomotor activation effects. Furthermore, the BOLD signal is dependent on various physiological parameters and it can be difficult to disentangle true vasomotor reactivity due to hypercapnic and hyperoxic gas from false activation effects that arise due to motion artefacts or natural physiological fluctuations influencing blood oxygenation. In this study we investigated the impact of various physiological correction models, both on the signal variance and TSNR, as well as activation parameters during air-only breathing (resting-state) and in response to a vasoactive stimulus design. Respiratory effects were the dominant source of physiological noise in this study and registration of the dynamic series was important both in increasing TSNR and reducing false-positive activation effects, even when motion artefacts were small. After registration and correction for low-frequency hardware drifts, the optimized RETROICOR model accounted for the largest amount of additional signal variance. The subsequent increase in TSNR after application of RETROICOR translated to an improvement in BOLD sensitivity, demonstrated by the highly significant difference (P  =  0.002) between resting-state and vasoactive scans, illustrated in figure 4 (column 3). As the phase of respiration relative to the timing of image acquisition is expected to vary randomly, removing signal components that are correlated with the respiratory phase waveform intuitively should decrease signal variance and improve BOLD sensitivity. This approach could also be generalized to BOLD and T1-weighted oxygen-enhanced experiments investigating changes in oxygenation of healthy and diseased tissue, to improve detection of the small changes induced by the step change in inspired oxygen fraction. The performance of the optimized RETROICOR was not reported on unregistered data, as preliminary work demonstrated that applying the RETROICOR algorithm without registration did not perform as well (Wallace et al 2016b). Furthermore, in a study by Jones et al (2008) investigating the introduction of motion correction parameters into a RETROICOR-based regression paradigm in the brain, it was demonstrated that the optimal order of corrections in terms of temporal standard deviation reduction resulted by performing image registration prior to RETROICOR. This is expected, since the RETROICOR model does not account for movement of physiological fluctuations between voxels. The ‘2R11X’ model was chosen as the optimal RETROICOR model as it accounted for significant variance in the data, without over-fitting to noise. The first order respiratory regressor accounted for the largest amount of structured noise in the BOLD signal. This regressor is likely to be correlated with the residual motion artefact or magnetic susceptibility changes that occur due to thoracic movement during respiration. Cardiac fluctuations did not account for a significant amount of noise in the data. In the brain, the magnitude of signal variation due to cardiac effects is often largest around major vessels (Dagli et al 1999, Glover et al 2000), so the absence of large vascular structures in the breast may help explain why the cardiac regressors were not useful in explaining BOLD signal variance in this case. The effect of including higher order respiratory or multiplicative harmonics was not found to be significant. We also investigated the impact of including regressors describing low-frequency variation in heart rate and inspired respiratory volume per unit time, as these have been shown to be another source of signal variance in the fMRI literature. In agreement with previous studies in the brain, the HR and RVT regressors accounted for additional signal variance in the fibroglandular tissue ROI and led to incremental improvements in TSNR and a reduction of false-positive activation effects in the resting-state data (Shmueli et al 2007, Hutton et al 2011). Variations in the depth and rate of breathing will alter arterial CO2 levels. It has also been proposed that CO2-mediated vasodilation will in turn trigger chemoreflexes to adjust the depth and rate of subsequent breaths in order to maintain optimal blood gas parameters, thus forming a feedback cycle. The period of this chemoreflex-mediated feedback cycle has been measured between 25 s and several minutes, resulting in low frequency (<0.04 Hz) temporal fluctuations (Van Den Aardweg and Karemaker 2002). Therefore, accounting for subtle variations in heart rate and breathing patterns that occur naturally at rest intuitively will explain some of the variance in the BOLD signal and help account for false-positive activations. Although increased TSNR should improve BOLD sensitivity, inclusion of lagged HR and RVT time courses in the regression model had a detrimental effect on the detection of vasomotor response to the vasoactive stimulus. This may be explained by the moderate correlations between the experimental design and these physiological time courses, evidenced by the peaks in the Fourier power spectra at the stimulus frequency. Kong et al (2012) similarly found that although regression of HR and RVT reduced BOLD signal variance, regression of these physiological time courses had a negative impact on parameter estimation in response to a painful thermal stimulus design due to concurrent changes in heart rate and breathing patterns. Without ground truth it is difficult to determine the relative impact of these processes, which may either remove false-positive activation effects or remove true active pixels that share variance with HR and RVT. In this case, the latter possibility is highly likely, given the established relationship between HR, RVT and blood CO2 levels, which is the source of the BOLD contrast being manipulated in this experiment. Therefore, although the combination of all regressors (Model 5) gave the largest improvement in TSNR, Model 2 gives the greatest improvement in BOLD sensitivity. Several limitations are recognized in this work. First, we did not directly measure changes in end tidal CO2, which may have helped to disentangle BOLD reactivity to the inspired CO2 fraction from BOLD contrast changes due to fluctuations in RVT. Increased ventilation causes arterial oxygen saturation to increase on the order of ~1%, which would further reduce deoxyhaemoglobin levels in venous blood. In subjects where the correlation between RVT and BOLD response was particularly strong, it is possible that hyperventilation during carbogen breathing artificially increased the apparent reactivity to CO2; however, further work is needed to elucidate the exact mechanisms of BOLD response. Second, the temporal resolution of the BOLD acquisition used in this experiment (4 s/image) may not be able to sufficiently model cardiac noise fluctuations due to aliasing, which could provide an alternative explanation as to why inclusion of cardiac phase regressors did not have a significant impact on BOLD signal variability. Third, due to the nature of the GLM regression analysis, any shared variance between the physiological noise regressors and the BOLD signal will be removed, thereby reducing the detected BOLD activation for regressors correlated with the stimulus design. The cardiac and respiratory response functions derived in fMRI experiments were not applied here as they have not been found to be beneficial outside the brain (Kong et al 2012). In conclusion, these results demonstrate that reducing signal variance attributed to physiological processes is associated with changes in activation parameter calculation, confirming the importance of certain physiological corrections in reliably detecting functional changes in the breast. The ‘2R11X’ RETROICOR model was found to be optimal in accounting for signal variance without over-fitting to noise and improved detection of BOLD activation effects. Subtle variations in HR and RVT that occurred naturally at rest accounted for additional variance in the resting-state BOLD data. However, inclusion of these regressors in the physiological noise model is not recommended as they appear to be correlated with the vasoactive stimulus design, making it difficult to disentangle BOLD signal reactivity due to CO2 changes from the associated ventilatory and cardiac responses.
  34 in total

1.  Localization of cardiac-induced signal change in fMRI.

Authors:  M S Dagli; J E Ingeholm; J V Haxby
Journal:  Neuroimage       Date:  1999-04       Impact factor: 6.556

2.  Influence of chemoreflexes on respiratory variability in healthy subjects.

Authors:  Joost G Van den Aardweg; John M Karemaker
Journal:  Am J Respir Crit Care Med       Date:  2002-04-15       Impact factor: 21.405

3.  Vasomodulation of skeletal muscle BOLD signal.

Authors:  Daniel P Bulte; Jeff Alfonsi; Sonya Bells; Michael D Noseworthy
Journal:  J Magn Reson Imaging       Date:  2006-10       Impact factor: 4.813

4.  How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan duration.

Authors:  Kevin Murphy; Jerzy Bodurka; Peter A Bandettini
Journal:  Neuroimage       Date:  2006-11-22       Impact factor: 6.556

5.  Brainstem functional magnetic resonance imaging: disentangling signal from physiological noise.

Authors:  Ann K Harvey; Kyle T S Pattinson; Jonathan C W Brooks; Stephen D Mayhew; Mark Jenkinson; Richard G Wise
Journal:  J Magn Reson Imaging       Date:  2008-12       Impact factor: 4.813

6.  Integration of motion correction and physiological noise regression in fMRI.

Authors:  Tyler B Jones; Peter A Bandettini; Rasmus M Birn
Journal:  Neuroimage       Date:  2008-05-21       Impact factor: 6.556

7.  k-Space detection and correction of physiological artifacts in fMRI.

Authors:  B Wowk; M C McIntyre; J K Saunders
Journal:  Magn Reson Med       Date:  1997-12       Impact factor: 4.668

8.  Retrospective estimation and correction of physiological fluctuation in functional MRI.

Authors:  X Hu; T H Le; T Parrish; P Erhard
Journal:  Magn Reson Med       Date:  1995-08       Impact factor: 4.668

9.  Discrimination of large venous vessels in time-course spiral blood-oxygen-level-dependent magnetic-resonance functional neuroimaging.

Authors:  A T Lee; G H Glover; C H Meyer
Journal:  Magn Reson Med       Date:  1995-06       Impact factor: 4.668

10.  Effects of breathing a hyperoxic hypercapnic gas mixture on blood oxygenation and vascularity of head-and-neck tumors as measured by magnetic resonance imaging.

Authors:  Mark Rijpkema; Johannes H A M Kaanders; Frank B M Joosten; Albert J van der Kogel; Arend Heerschap
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

View more
  1 in total

Review 1.  fMRI studies evaluating central respiratory control in humans.

Authors:  Carolina Ciumas; Sylvain Rheims; Philippe Ryvlin
Journal:  Front Neural Circuits       Date:  2022-09-23       Impact factor: 3.342

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.