Literature DB >> 27966012

[Surface replacement of proximal interphalangeal joints using CapFlex-PIP].

S F Schindele1, A Altwegg2, S Hensler3.   

Abstract

OBJECTIVE OF SURGERY: The cementless implantation of the surface replacement CapFlex-PIP enables pain relief, preservation of motion, improves lateral stability and corrects axis deviation in proximal interphalangeal (PIP) joints of patients with primary and secondary PIP osteoarthritis. INDICATIONS: Painful PIP joints as a result of degenerative or posttraumatic osteoarthritis with restriction of motion. Secondary inflammatory destruction of PIP joints in rheumatoid arthritis with low inflammatory activity and good bone conditions. CONTRAINDICATIONS: Destruction of PIP joints with severe bone loss, osseous defects and chronic joint luxation. Joint destruction induced by florid or subacute bacterial arthritis. Skin infections. SURGICAL TECHNIQUE: Dorsal or palmar incision over the affected PIP joint while sparing the peritendinous tissue. Exposure of the proximal phalangeal head and meticulous bone resection. Precontouring of the bone bed for proximal prosthesis. Insertion of the trial prosthesis. Exposure of the distal base and resection in the correct axis. Determination of distal prosthesis size and height of the polyethylene inlay. Insertion of the trial prosthesis without bone protrusion. After clinical and radiological control, implantation of the final prosthesis. FOLLOW-UP: Long finger splint, palmar flexor support splint for 2-3 weeks with active mobilization. Then active free mobilization with a twin bandage. After 6 weeks radiological check and free functional mobilization.
RESULTS: The active range of motion of 50 patients increased from 43.4° before surgery to 55.9° after 1 year with concomitant pain relief (6.5 to 2.2). In one case revision surgery was required due to traumatic rupture of the radial collateral ligament and four secondary tenolyses were performed.

Entities:  

Keywords:  Arthroplasty; Fingers; Joint prosthesis; Osteoarthritis; Range of motion

Mesh:

Year:  2016        PMID: 27966012     DOI: 10.1007/s00064-016-0475-3

Source DB:  PubMed          Journal:  Oper Orthop Traumatol        ISSN: 0934-6694            Impact factor:   1.154


  9 in total

1.  Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load-bearing in vivo model for small joint arthroplasty.

Authors:  Wolfgang Daecke; Katrin Veyel; Peter Wieloch; Martin Jung; Helga Lorenz; Abdul-Kader Martini
Journal:  J Hand Surg Am       Date:  2006-01       Impact factor: 2.230

2.  Problematic bone fixation with pyrocarbon implants in proximal interphalangeal joint replacement: short-term results.

Authors:  D B Herren; S Schindele; J Goldhahn; B R Simmen
Journal:  J Hand Surg Br       Date:  2006-10-12

Review 3.  Pyrocarbon proximal interphalangeal joint arthroplasty: outcomes of a cohort study.

Authors:  D T McGuire; C D White; S L Carter; M W Solomons
Journal:  J Hand Surg Eur Vol       Date:  2011-12-22

4.  Insertion of the Ascension PyroCarbon PIP total joint in 152 human cadaver fingers: analysis of implant positions and malpositions.

Authors:  Bernd Hohendorff; W Zhang; K J Burkhart; L P Müller; C Ries
Journal:  Arch Orthop Trauma Surg       Date:  2014-12-13       Impact factor: 3.067

5.  A modular surface gliding implant (CapFlex-PIP) for proximal interphalangeal joint osteoarthritis: a prospective case series.

Authors:  Stephan F Schindele; Stefanie Hensler; Laurent Audigé; Miriam Marks; Daniel B Herren
Journal:  J Hand Surg Am       Date:  2014-12-13       Impact factor: 2.230

6.  Osteointegration of a modular metal-polyethylene surface gliding finger implant: a case report.

Authors:  Stephan F Schindele; Christoph M Sprecher; Stefan Milz; Stefanie Hensler
Journal:  Arch Orthop Trauma Surg       Date:  2016-07-23       Impact factor: 3.067

7.  Arthrodesis of the distal interphalangeal joint: description of a new technique and clinical follow-up at 2 years.

Authors:  L C Olivier; F Gensigk; T N Board; D Kendoff; U Krehmeier; U Wolfhard
Journal:  Arch Orthop Trauma Surg       Date:  2007-10-11       Impact factor: 3.067

Review 8.  Hand osteoarthritis: an epidemiological perspective.

Authors:  Leonid Kalichman; Gabriela Hernández-Molina
Journal:  Semin Arthritis Rheum       Date:  2009-05-31       Impact factor: 5.532

9.  [Moje prosthesis for the proximal interphalangeal joint].

Authors:  A Wesemann; M Flügel; M Mamarvar
Journal:  Handchir Mikrochir Plast Chir       Date:  2008-06-12       Impact factor: 1.018

  9 in total
  4 in total

1.  [Surgical approaches to the hand].

Authors:  B Hohendorff; F Unglaub; C K Spies; K Wegmann; L P Müller; C Ries
Journal:  Oper Orthop Traumatol       Date:  2019-07-29       Impact factor: 1.154

Review 2.  [Percutaneous treatment of unstable fractures of the base of the middle phalanx : Technique according to Hintringer and Ender].

Authors:  S Quadlbauer; C Pezzei; W Hintringer; T Hausner; M Leixnering
Journal:  Oper Orthop Traumatol       Date:  2019-07-25       Impact factor: 1.154

Review 3.  [Open reduction and plate/screw osteosynthesis of proximal phalanx fractures].

Authors:  F Unglaub; M F Langer; S Löw; B Hohendorff; C K Spies
Journal:  Oper Orthop Traumatol       Date:  2019-04-12       Impact factor: 1.154

4.  [Corrective osteotomy of the hand].

Authors:  Frank Unglaub; Martin F Langer; Julia M Unglaub; Christian K Spies
Journal:  Unfallchirurg       Date:  2018-08       Impact factor: 1.000

  4 in total