| Literature DB >> 27956077 |
Senol Bekmez1, Mehmet Ayvaz2, Altug Yucekul2, Mazhar Tokgozoglu2.
Abstract
INTRODUCTION: The aim of the study is to report the preliminary clinical and functional outcomes of a modular cementless tumor resection prosthesis system (Megasystem-C®, Waldemar Link GmbH&Co. KG, Hamburg, Germany) in patients undergoing limb salvage surgery with wide resection in a lower extremity primary or metastatic malignant bone tumor.Entities:
Keywords: Bone tumor; Cementless; Limb salvage; Modular; Tumor prosthesis
Mesh:
Year: 2016 PMID: 27956077 PMCID: PMC6197450 DOI: 10.1016/j.aott.2016.05.004
Source DB: PubMed Journal: Acta Orthop Traumatol Turc ISSN: 1017-995X Impact factor: 1.511
Patient demographics and tumor characteristics.
| Diagnosis | Number | Mean age | Gender | R/L | Tumor localization | |||
|---|---|---|---|---|---|---|---|---|
| Proximal femur | Diaphysis femur | Distal femur | Proximal tibia | |||||
| Osteosarcoma | 17 | 20.1 | 5/12 | 10/7 | 3 | 2 | 7 | 5 |
| Ewing sarcoma | 7 | 17.1 | 3/4 | 3/4 | – | 2 | 3 | 2 |
| Metastases | 11 | 60.8 | 4/7 | 7/4 | 6 | 2 | 3 | – |
| Giant cell tumor | 5 | 32.6 | 3/2 | 2/3 | – | – | 3 | 2 |
| Chondrosarcoma | 5 | 55.4 | 2/3 | 4/1 | 3 | 1 | 1 | – |
| Others | 7 | 51.4 | 2/5 | 3/4 | 5 | 2 | – | – |
| Overall | 52 | 37.1 | 19/33 | 29/23 | 17 | 9 | 17 | 9 |
Including multiple myeloma, liposarcoma, leiomyosarcoma, synovial sarcoma, neurofibrosarcoma.
Classification of the mode of failure in tumor resection prosthesis reconstruction as described by Henderson et al.
| Type of failure | Description | |
|---|---|---|
| Mechanical | 1 | Instability, tendon rupture, aseptic wound dehiscence |
| 2 | Clinical and radiographic evidence of aseptic loosening | |
| 3 | Periprosthetic or prosthetic fracture | |
| Non-mechanical | 4 | Infection requiring removal of prosthesis |
| 5 | Recurrence or progression of tumor | |
Fig. 1Kaplan–Meier analysis diagram demonstrating the overall patient survival.
Fig. 2Kaplan–Meier analysis diagram demonstrating the implant survival with using prosthesis removal as an end-point.
Distribution of complications according to type of reconstruction.
| Number | Complications (%) | |||||||
|---|---|---|---|---|---|---|---|---|
| Soft-tissue complication | Aseptic loosening | Structural failure | Infection | Tumor progression | Total | |||
| Reconstruction | Proximal femur | 18 | – | – | 1 | 1 | 1 | 3 |
| Total femur | 6 | 1 | – | – | – | – | 1 | |
| Distal femur | 18 | 3 | – | 1 | 3 | 2 | 9 | |
| Proximal tibia | 10 | 2 | – | – | 3 | – | 5 | |
| Overall | 52 | 6 | – | 2 | 7 | 3 | 18 | |
Distribution of the complications according to diagnosis.
| Number | Complications (%) | |||||||
|---|---|---|---|---|---|---|---|---|
| Soft-tissue complication | Aseptic loosening | Structural failure | Infection | Tumor progression | Total | |||
| Diagnosis | Osteosarcoma | 17 | 5 | – | – | 4 | 1 | 10 |
| Ewing sarcoma | 7 | – | – | – | 1 | – | 1 | |
| Metastasis | 11 | – | – | 1 | – | 2 | 3 | |
| Giant cell tumor | 5 | – | – | 1 | 1 | 2 | ||
| Chondrosarcoma | 5 | 1 | – | – | 1 | – | 2 | |
| Others | 7 | – | – | – | – | – | – | |
| Overall | 52 | 6 | – | 2 | 7 | 3 | 18 | |
Including multiple myeloma, liposarcoma, leiomyosarcoma, synovial sarcoma, neurofibrosarcoma.
Fig. 3MSTS scores according to different anatomical regions. Please note that, average MSTS score in proximal tibial reconstructions is lower than the other anatomical regions.
Fig. 4A 54 years-old male admitted to our department with a pathological fracture in the right proximal femur due to lung carcinoma metastasis (a). Wide resection and reconstruction with modular cementless tumor resection prosthesis (b). Five months later, he admitted to the emergency department with significant thigh pain. Radiograph demonstrates the rotational instability between prosthetic modules caused by module dislodgement (c). The patient underwent revision surgery (d).
Fig. 5In the final version which is in clinical use now, body segments or the stem are impacted together with a specially designed impaction instrumentation and then using two screws opposite, the joined two segments are locked rigidly. After the modification, no segment dislodgement occurred (Courtesy of Waldemar Link GmbH&Co. KG, Hamburg, Germany).