Literature DB >> 2795416

Polaroid photorefractive screening of infants.

C Hsu-Winges1, R D Hamer, A M Norcia, H Wesemann, C Chan.   

Abstract

We modified a Polaroid SE camera for use as a photoretinoscope. A total of 187 infants between 2 and 18 months of age were photographed using this device. About half of these infants (97) participated in a double blind study in which the results of photorefraction were compared with those of standard cycloplegic retinoscopy. Eighty-three infants were photographed without cycloplegia. Thirty-four infants were photographed while cyclopleged. Photographs were evaluated for significant refractive errors and other ocular abnormalities. The effectiveness of the camera system to screen for significant refractive errors without the use of cycloplegia was assessed. Infants were identified to be at risk by photorefraction if, in any photograph, a hyperopic bright crescent calculated to be greater than or equal to +1.25 D was present in the pupil. Clinically significant refractive errors were defined by the results of cycloplegic retinoscopy: "at-risk" infants had either 3.5 D or more hyperopia in either eye, or astigmatism in either eye greater than or equal to 2.5 D, or anisometropia greater than or equal to 1.5 D. With these clinical criteria and the above photographic screening criterion, the camera's sensitivity and specificity were 83% and 69%, respectively. The present system compares favorably with earlier, more sophisticated units in alerting practitioners to potentially significant refractive errors in infants. Additionally, as a screening tool, this device offers the benefits of being inexpensive and easy to use, and of providing immediate feedback.

Entities:  

Mesh:

Year:  1989        PMID: 2795416     DOI: 10.3928/0191-3913-19890901-12

Source DB:  PubMed          Journal:  J Pediatr Ophthalmol Strabismus        ISSN: 0191-3913            Impact factor:   1.402


  3 in total

1.  Measurement of the validity of a preschool vision screening program.

Authors:  B Robinson; W R Bobier; E Martin; L Bryant
Journal:  Am J Public Health       Date:  1999-02       Impact factor: 9.308

2.  Accuracy of a new photo-refractometer in young and adult patients.

Authors:  Thilo Schimitzek; Wolf A Lagrèze
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-01-14       Impact factor: 3.117

3.  Video vision development assessment (VVDA): combining the Brückner test with eccentric photorefraction for dynamic identification of amblyogenic factors in infants and children.

Authors:  G W Cibis
Journal:  Trans Am Ophthalmol Soc       Date:  1994
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.