Comparison of the trabecular and cortical tissue moduli from human iliac crests.

J L Kuhn1, S A Goldstein, K Choi, M London, L A Feldkamp, L S Matthews.   

Abstract

The purpose of this study was to design a method to produce and test mechanically microspecimens of trabecular and cortical tissue from human iliac crests, and compare their measured moduli. Rectangular beam specimens were prepared on a low-speed diamond blade saw and a miniature milling machine. The final specimen dimensions ranged from approximately 50-200 microns for base and height. The modulus of each specimen was measured using three-point bending tests across a span length of 1.04 mm and performed at a constant rate of displacement. A subset of specimens was recovered for a radiographic estimation of degree of mineralization. The results showed the mean trabecular tissue modulus of all iliac crest specimens to be 3.81 GPa, whereas cortical tissue specimens averaged 4.89 GPa. This was a significant difference according to a two-way analysis of variance that controlled for differences between donors. No strong correlations were found between modulus and mineral density. Future investigations that consider other microstructural characteristics and their contributions to modulus, and specimen size effects, are indicated.

Entities:  

Mesh:

Year:  1989        PMID: 2795328     DOI: 10.1002/jor.1100070614

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  17 in total

1.  Fabrication and mechanical properties of PLLA/PCL/HA composites via a biomimetic, dip coating, and hot compression procedure.

Authors:  L F Charles; M T Shaw; J R Olson; M Wei
Journal:  J Mater Sci Mater Med       Date:  2010-03-18       Impact factor: 3.896

Review 2.  Methods for assessing bone quality: a review.

Authors:  Eve Donnelly
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 3.  Biomechanics and mechanobiology of trabecular bone: a review.

Authors:  Ramin Oftadeh; Miguel Perez-Viloria; Juan C Villa-Camacho; Ashkan Vaziri; Ara Nazarian
Journal:  J Biomech Eng       Date:  2015-01       Impact factor: 2.097

4.  Hierarchical analysis and multi-scale modelling of rat cortical and trabecular bone.

Authors:  Ramin Oftadeh; Vahid Entezari; Guy Spörri; Juan C Villa-Camacho; Henry Krigbaum; Elsa Strawich; Lila Graham; Christian Rey; Hank Chiu; Ralph Müller; Hamid Nayeb Hashemi; Ashkan Vaziri; Ara Nazarian
Journal:  J R Soc Interface       Date:  2015-05-06       Impact factor: 4.118

5.  Voxel-based micro-finite element analysis of dental implants in a human cadaveric mandible: Tissue modulus assignment and sensitivity analyses.

Authors:  Qiyuan Mao; Kangning Su; Yuxiao Zhou; Mehran Hossaini-Zadeh; Gregory S Lewis; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2019-03-13

6.  Transgenic mouse model of the mild dominant form of osteogenesis imperfecta.

Authors:  J Bonadio; T L Saunders; E Tsai; S A Goldstein; J Morris-Wiman; L Brinkley; D F Dolan; R A Altschuler; J E Hawkins; J F Bateman
Journal:  Proc Natl Acad Sci U S A       Date:  1990-09       Impact factor: 11.205

7.  Trabecular microfracture and the influence of pyridinium and non-enzymatic glycation-mediated collagen cross-links.

Authors:  Christopher J Hernandez; Simon Y Tang; Bethany M Baumbach; Paul B Hwu; A Nico Sakkee; Frits van der Ham; Jeroen DeGroot; Ruud A Bank; Tony M Keaveny
Journal:  Bone       Date:  2005-09-02       Impact factor: 4.398

Review 8.  Measurement and significance of three-dimensional architecture to the mechanical integrity of trabecular bone.

Authors:  S A Goldstein; R Goulet; D McCubbrey
Journal:  Calcif Tissue Int       Date:  1993       Impact factor: 4.333

9.  Broadband ultrasound attenuation signals depend on trabecular orientation: an in vitro study.

Authors:  C C Glüer; C Y Wu; H K Genant
Journal:  Osteoporos Int       Date:  1993-07       Impact factor: 4.507

10.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.