| Literature DB >> 2794240 |
R Hari1, M Hämäläinen, S L Joutsiniemi.
Abstract
Steady-state magnetic responses to clicks presented at rates between 10 and 70 Hz have been recorded in healthy humans. The responses were highest in amplitude around 40 Hz. This amplitude enhancement is satisfactorily explained by summation of responses evoked by single clicks. The field maps suggest activation of the auditory cortex at all stimulus frequencies. Similar responses were obtained with gated noise bursts and by pauses in a series of clicks. The mean "apparent latency," determined from the phase lag at rates 30-70 Hz, was 54 ms. The physiological relevance of this quantity is shown to be questionable.Entities:
Mesh:
Year: 1989 PMID: 2794240 DOI: 10.1121/1.398093
Source DB: PubMed Journal: J Acoust Soc Am ISSN: 0001-4966 Impact factor: 1.840