| Literature DB >> 27931261 |
Ivan Puhar1,2, Li Ma2, Dina Suleimenova2, Vasileios Chronopoulos2, Nikos Mattheos3.
Abstract
BACKGROUND: The objective of this pilot study was to evaluate the effect of local application of low-magnitude high-frequency vibration (LMHFV) on the bone healing of rabbit calvarial defects that were augmented with different grafting materials and membranes.Entities:
Keywords: Animal experiments; Biomaterials; Bone substitutes; Guided bone regeneration; Morphometric analysis; Vibration; Wound healing
Mesh:
Year: 2016 PMID: 27931261 PMCID: PMC5144494 DOI: 10.1186/s13018-016-0494-7
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Fig. 1Left, central, and right area were used for histomorphometric analysis (original magnification ×50)
Fig. 2Identification of different tissue types using 10 × 10 grid points
Percentages of various tissues in control and experimental defects among different materials
| BCP (%) | BO/BG (%) | BCP/SR (%) | BG (%) | |||||
|---|---|---|---|---|---|---|---|---|
| Control | Vibration | Control | Vibration | Control | Vibration | Control | Vibration | |
| Osteoid (OS) | 0.0 | 0.0 | 1.0 | 9.3 | 2.0 | 17.3 | 19.3 | 35.3 |
| Fibrous tissue (FB) | 32.3 | 34.3 | 24.3 | 18.7 | 36.7 | 40.7 | 4.7 | 24.7 |
| Blood clot (BL) | 39.0 | 34.0 | 34.3 | 31.7 | 36.0 | 19.7 | 76.0 | 40.0 |
| Grafting material (GR) | 28.7 | 31.7 | 40.3 | 40.3 | 25.3 | 22.3 | 0.0 | 0.0 |
Fig. 3Comparison of different tissue percentages for the control defects. BCP = biphasic calcium phosphate; BO/BG = deproteinized bovine bone mineral covered with a non-cross-linked collagen membrane; BCP/SR = biphasic calcium phosphate covered with a strontium hydroxyapatite-containing collagen membrane; BG = non-cross-linked collagen membrane
Fig. 4Comparison of different tissue percentages for the experimental defects. BCP = biphasic calcium phosphate; BO/BG = deproteinized bovine bone mineral covered with a non-cross-linked collagen membrane; BCP/SR = biphasic calcium phosphate covered with a strontium hydroxyapatite-containing collagen membrane; BG = non-cross-linked collagen membrane
Relationship between osteoid values and the independent variables in the full model
| Independent variables | Estimate | S.E. |
| Observed power |
|---|---|---|---|---|
| Material type | 0.045 | 0.660 | ||
| BCP (1) | –27.30 | 5.28 | 0.014 | |
| BO/BG (2) | –22.15 | 5.28 | 0.025 | |
| BCP/SR (3) | –17.65 | 5.28 | 0.044 | |
| BG (4) | 0 | |||
| Vibration | 0.077 | 0.446 | ||
| No | –9.90 | 3.73 | 0.077 | |
| Yes | 0 | |||
|
| 32.25 | 4.17 | 0.004 |
Relationship between grafting material values and the independent variables in the full model
| Independent variables | Estimate | S.E. |
| Observed power |
|---|---|---|---|---|
| Material type | 0.001 | 1.000 | ||
| BCP (1) | 30.20 | 1.73 | <0.001 | |
| BO/BG (2) | 40.30 | 1.73 | <0.001 | |
| BCP/SR (3) | 23.80 | 1.73 | 0.001 | |
| BG (4) | 0 | |||
| Vibration | 1.000 | 0.050 | ||
| No | –7.105E-15 | 1.23 | ||
| Yes | 0 | |||
|
| 1.776E-14 | 1.37 | 1.000 |