| Literature DB >> 27931181 |
K Kukula1, M Klopotowski2, P K Kunicki3, J Jamiolkowski4, A Debski2, P Bekta2, M Polanska-Skrzypczyk2, Z Chmielak2, A Witkowski2.
Abstract
BACKGROUND: Platelet aggregation monitoring in diabetic patients treated with coronary interventions (PCI) for an acute coronary syndrome (ACS) is a promising way of optimizing treatment and outcomes in this high risk group. The aim of the study was to verify whether clopidogrel response measured by Multiplate analyzer (ADPtest) in diabetic ACS patients treated with PCI predicts the risk of stent thrombosis or cardiovascular mortality and bleeding.Entities:
Keywords: Acute coronary syndrome; Coronary intervention; Diabetes; Platelet aggregation; Stent thrombosis
Mesh:
Substances:
Year: 2016 PMID: 27931181 PMCID: PMC5146852 DOI: 10.1186/s12872-016-0433-x
Source DB: PubMed Journal: BMC Cardiovasc Disord ISSN: 1471-2261 Impact factor: 2.298
Fig. 1ROC curve calculated for ADP-dependent platelet aggregation as assessed by MEA (ADPtest)
Clinical and demographic data of the studied group with respect to platelet aggregation assessed by MEA Multiplate analyzer at the cutoff point of 345 AUmin
| ADPtest | ADPtest |
| |
|---|---|---|---|
| <345 AU × min | 345 ≥ AU × min | ||
|
|
| ||
| Age (years) (mean ± SD) | 66.5 ± 11.1 | 69.6 ± 10.8 |
|
| Male (%) | 109 (68%) | 29 (72.5%) |
|
| STEMI (%) | 74 (53%) | 20 (50%) |
|
| ASPItest (AU x min) | 88.9 ± 73.0 | 173.1 ± 150.0 |
|
| Drug eluting stent | 132 (94%) | 33 (83%) |
|
| Stent diameter (mm) (median) | 3.0 | 3.0 |
|
| Stent (s) length (mm) | 18.0 | 22.0 |
|
| Inflation pressure (atm) (median) | 16.0 | 16.0 |
|
| Fibrinogen (mg/dL) (mean ± SD) | 451 ± 133 | 480 ± 138 |
|
| LDL (mmol/L) (mean ± SD) | 2.83 ± 1.1 | 2.58 ± 0.9 |
|
| Creatinine (umol/L) (mean ± SD) | 92.9 ± 34.4 | 103.4 ± 67.6 |
|
| hsCRP (mg/dL) (median) | 0.4 | 0.5 |
|
| Platelet count (103/ml) (mean ± SD) | 204 ± 60 | 223 ± 70 |
|
| White blood count (103/ml) (mean ± SD) | 8.65 | 8.45 |
|
| Hemoglobin (mg/dL) (median) | 13.8 | 12.8 |
|
| Insulin therapy | 46 (33%) | 15 (38%) |
|
Fig. 2a Hazard ratio values of stent thrombosis (as described in the Figure) plotted as HR with 95% confidence intervals for standard MEA cutoff value of 468 AUmin; Inset (b) Hazard ratio values of stent thrombosis and cardiovascular mortality (as described in the Figure) for the cutoff of 345 AUmin that allowed for better risk stratification in the studied cohort