Literature DB >> 27931005

Microfluidic immunosensor for rapid and highly-sensitive salivary cortisol quantification.

V Pinto1, P Sousa1, S O Catarino1, M Correia-Neves2, G Minas3.   

Abstract

This paper presents a novel poly(dimethylsiloxane) (PDMS) microfluidic immunosensor that integrates a complementary metal-oxide-semiconductor (CMOS) optical detection system for a rapid and highly-sensitive quantification of salivary cortisol. The simple and non-invasive method of saliva sampling provides an interesting alternative to the blood, allowing a fast sampling at short intervals, relevant for many clinical diagnostic applications. The developed approach is based on the covalent immobilization of a coating antibody (Ab), a polyclonal anti-IgG, onto a treated PDMS surface. The coating Ab binds the capture Ab, an IgG specific for cortisol, allowing its correct orientation. Horseradish peroxidase (HRP)-labelled cortisol is added to compete with the cortisol in the sample, for the capture Ab binding sites. The HRP-labelled cortisol, bonded to the capture Ab, is measured through the HRP enzyme and the tetramethylbenzidine (TMB) substrate reaction. The cortisol quantification is performed by colorimetric detection of HRP-labelled cortisol, through optical absorption at 450nm, using a CMOS silicon photodiode as the photodetector. Under the developed optimized conditions presented here, e.g., microfluidic channels geometry, immobilization method and immunoassay conditions, the immunosensor shows a linear range of detection between 0.01-20ng/mL, a limit of detection (LOD) of 18pg/mL and an analysis time of 35min, featuring a great potential for point-of-care applications requiring continuous monitoring of the salivary cortisol levels during a circadian cycle.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Colorimetric detection; Lab-on-a-chip (LOC); Microfluidic immunosensor; Poly(dimethylsiloxane); Salivary cortisol

Mesh:

Substances:

Year:  2016        PMID: 27931005     DOI: 10.1016/j.bios.2016.11.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Label-free plasmonic immunosensor for cortisol detection in a D-shaped optical fiber.

Authors:  Maria S Soares; Luís C B Silva; Miguel Vidal; Médéric Loyez; Margarida Facão; Christophe Caucheteur; Marcelo E V Segatto; Florinda M Costa; Cátia Leitão; Sónia O Pereira; Nuno F Santos; Carlos A F Marques
Journal:  Biomed Opt Express       Date:  2022-05-09       Impact factor: 3.562

2.  A novel nucleic acid amplification system based on nano-gap embedded active disk resonators.

Authors:  Eun Yeong Lee; Yeseul Kim; Bonhan Koo; Geun Su Noh; Hansuek Lee; Yong Shin
Journal:  Sens Actuators B Chem       Date:  2020-05-26       Impact factor: 7.460

Review 3.  Clinical and Technical Aspects in Free Cortisol Measurement.

Authors:  Man Ho Choi
Journal:  Endocrinol Metab (Seoul)       Date:  2022-08-19

Review 4.  Cost-Effective Fiber Optic Solutions for Biosensing.

Authors:  Cátia Leitão; Sónia O Pereira; Carlos Marques; Nunzio Cennamo; Luigi Zeni; Madina Shaimerdenova; Takhmina Ayupova; Daniele Tosi
Journal:  Biosensors (Basel)       Date:  2022-07-28

5.  Salivary Cortisol Determination on Smartphone-Based Differential Pulse Voltammetry System.

Authors:  Jingjing Liu; Ning Xu; Hong Men; Shuang Li; Yanli Lu; Sze Shin Low; Xin Li; Lihang Zhu; Chen Cheng; Gang Xu; Qingjun Liu
Journal:  Sensors (Basel)       Date:  2020-03-05       Impact factor: 3.576

Review 6.  Immunosensing Based on Optical Fiber Technology: Recent Advances.

Authors:  Maria Simone Soares; Miguel Vidal; Nuno F Santos; Florinda M Costa; Carlos Marques; Sónia O Pereira; Cátia Leitão
Journal:  Biosensors (Basel)       Date:  2021-08-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.