| Literature DB >> 27923700 |
P R Wahl1, I Pucher1, O Scheibelhofer1, M Kerschhaggl2, S Sacher1, J G Khinast3.
Abstract
Near-infrared chemical imaging (NIR-CI) with high-speed cameras based on the push-broom acquisition principle is a rapidly-evolving and can be used for a variety of purposes, from classification (and sorting) of products to mapping spatial distribution of materials. The present study examined if NIR-CI is suitable for tablet manufacturing. To that end, the tablets were introduced into the CI system via a flat belt conveyor. A formulation, which consisted of 4wt.%-6wt.% caffeine, 5wt.% crospovidone as a disintegrant, 88wt.%-90wt.% lactose as a filler and 1wt.% magnesium stearate as a lubricator, was tableted at compression forces ranging from 5kN to 30kN. The intra- and inter-tablet homogeneity of caffeine and the tablet's hardness were analyzed via NIR-CI. For the homogeneity evaluation, two methods were applied: standard deviation (SD) and distributional homogeneity index (DHI). The results showed that the SD of caffeine in a single tablet increased with an increase in the caffeine content. This was attributed to natural variations in a binary mixture of caffeine and excipients. Overall, the chosen NIR-CI setup has strong potential to be transferred to the production scale to monitor all tablets in a production stream.Entities:
Keywords: Chemical imaging; Homogeneity; Near-infrared spectroscopy (NIR); Process analytical technology (PAT); Tableting
Mesh:
Substances:
Year: 2016 PMID: 27923700 DOI: 10.1016/j.ijpharm.2016.12.003
Source DB: PubMed Journal: Int J Pharm ISSN: 0378-5173 Impact factor: 5.875