| Literature DB >> 27915417 |
Wolfram Knöfler1, Thomas Barth2, Reinhard Graul3, Dietmar Krampe4.
Abstract
BACKGROUND: A sufficient amount of bone is essential to ensure long-term stability of dental implants. To support the bone regeneration process, different techniques and materials are available. It has been questioned whether these techniques and materials may compromise implant survival compared to pristine bone. To properly answer this question, long-term stability up to 20.2 years after insertion of implants placed in augmented or non-augmented sites was retrospectively analysed.Entities:
Keywords: Augmentation; Dental implant; Survival rate
Year: 2016 PMID: 27915417 PMCID: PMC5136376 DOI: 10.1186/s40729-016-0061-3
Source DB: PubMed Journal: Int J Implant Dent ISSN: 2198-4034
Distribution of implants according to the period of observation
| Year | Number of implants | Relative number of implants (%) |
|---|---|---|
| <1 | 1920 | 18.9 |
| 1 | 1175 | 11.6 |
| 2 | 843 | 8.30 |
| 3 | 918 | 9.04 |
| 4 | 794 | 7.82 |
| 5 | 779 | 7.67 |
| 6 | 728 | 7.17 |
| 7 | 578 | 5.69 |
| 8 | 531 | 5.23 |
| 9 | 454 | 4.47 |
| 10 | 346 | 3.41 |
| 11 | 297 | 2.92 |
| 12 | 247 | 2.43 |
| 13 | 169 | 1.66 |
| 14 | 104 | 1.02 |
| 15 | 104 | 1.02 |
| 16 | 56 | 0.55 |
| 17 | 71 | 0.70 |
| 18 | 22 | 0.22 |
| 19 | 19 | 0.19 |
| 20 | 1 | 0.01 |
| NA | 2 | 0.02 |
| Total | 10158 | 100.0 |
NA observation period not clearly determinable
Implant loss in augmented and non-augmented sites up to 20.2 years after implant insertion
| Augmentation | Implants ( | Lost implants % ( | Early implant loss % ( | Late implant loss % ( | Absolute survival rate % |
|---|---|---|---|---|---|
| No augmentation | 4242 | 5.73 (243) | 0.38 (16) | 5.35 (227) | 94.27 |
| With augmentation | 5916 | 3.67 (217) | 0.32 (19) | 3.35 (198) | 96.33 |
| Total | 10158 | 4.53 (460) | 0.34 (35) | 4.18 (425) | 95.47 |
Early implant loss (before connection of the suprastructure), late implant loss (after connection of the suprastructure). Metric parameters are calculated using descriptive statistics
Fig. 1a Kaplan-Meier survival curves for implants with or without augmentation. Dashed line 95% confidence interval. b Kaplan-Meier survival curves for single crown implants overall and with or without augmentation. Dashed line 95% confidence interval
Explantations of implants inserted using different augmentation procedures up to 20.2 years after implantation
| Augmentation procedure | Implants | Lost implants % ( | Absolute survival rate % |
|
|---|---|---|---|---|
| No augmentation | 4242 | 5.72 (243) | 94.28 | |
| Lateral augmentation | 3210 | 4.02 (129) | 95.98 | 0.0010 |
| External sinus lift one-step | 1101 | 4.09 (45) | 95.91 | 0.0324 |
| Bone condensing | 422 | 1.90 (8) | 98.1 | 0.0009 |
| Bone splitting/bone spreading | 374 | 3.74 (14) | 96.26 | 0.2998 |
| Internal sinus lift | 314 | 2.55 (8) | 97.45 | 0.0174 |
| Autogenous bone block transplantation | 241 | 3.32 (8) | 96.68 | 0.1146 |
| External sinus lift two-step | 130 | 1.54 (2) | 98.46 | 0.0410 |
| Three-dimensional augmentation using Ti-mesh | 124 | 2.42 (3) | 97.58 | 0.1159 |
Metric parameters are based on descriptive statistics. P values for pairwise comparison vs. no augmentation were calculated in accordance to Kaplan and Meier using log-rank test.
Fig. 2Kaplan-Meier implant survival curves for augmentation procedures
Explantations of implants per membrane type up to 20 years after implant insertion
| Membrane type | Implants | Min/max observation time (years) | Lost implants % ( | Absolute survival rate % |
|
|---|---|---|---|---|---|
| No membrane | 6439 | 0.0/20.2 | 4.77 (307) | 95.23 | |
| Geistlich Bio-Gide | 2743 | 0.0/16.2 | 3.76 (103) | 96.24 | 0.4462 |
| Geistlich Bio-Gide combined with other membranes | 279 | 0.0/10.2 | 3.23 (9) | 96.77 | 0.7809 |
| Gore-Tex | 230 | 0.4/18.5 | 5.65 (13) | 94.35 | 0.1671 |
| Vicryl | 224 | 0.0/18.4 | 6.70 (15) | 93.3 | 0.6808 |
| Tefgen | 81 | 0.2/16 | 2.47 (2) | 97.53 | 0.1638 |
| BioVin M | 65 | 0/1.9 | 1.54 (1) | 98.46 | 0.7816 |
| Tutodent | 49 | 0.1/5.9 | 8.16 (4) | 91.84 | 0.0555 |
| Resodont | 21 | 0.1/3.6 | 14.29 (3) | 85.71 | 0.0021 |
| Kollagen Vlies | 10 | 0.1/9.7 | 30.0 (3) | 70 | 0.0006 |
| Ossix | 8 | 8.0/8.9 | 0.00 (0) | 100 | 0.4781 |
| Osseoguard | 4 | 2.3/3.2 | 0.00 (0) | 100 | 0.7061 |
| Curasan InionGTR | 3 | 1.0/1.0 | 0.00 (0) | 100 | 0.7694 |
| Epigide | 2 | 4.9/4.9 | 0.00 (0) | 100 | 0.7680 |
| Total | 10158 | 0.0/20.2 | 4.53 (460) | 95.47 |
Metric parameters were calculated using descriptive statistics. P values for pairwise comparison vs. no membrane were calculated in accordance to Kaplan and Meier using log-rank test
Fig. 3Kaplan-Meier survival curves for membrane types
Implants lost and in function up to 20.2 years after implant insertion using different graft materials
| Graft material | Implants ( | Min/max observation time (years) | Lost implants % ( | Absolute survival rate % |
|
|---|---|---|---|---|---|
| No graft material | 4609 | 0.0/20.2 | 5.51 (254) | 94.49 | |
| Geistlich Bio-Oss | 2939 | 0.0/15.6 | 2.76 (81) | 97.24 | 0.0004 |
| Autogenous bone particles | 1801 | 0.0/17.8 | 3.94 (71) | 96.06 | 0.1807 |
| Cerasorb | 284 | 0.0/12.6 | 10.56 (30) | 89.44 | 0.0007 |
| Bioresorb | 145 | 0.1/11.6 | 6.90 (10) | 93.10 | 0.7782 |
| Bio-Oss + Cerasorb | 105 | 0.0/5.8 | 2.86 (3) | 97.14 | 0.6714 |
| Other bone substitutes | 275 | 0.0/18.6 | 4.00 (11) | 96 | 0.1354 |
| Total | 10158 | 0.0/20.2 | 4.53 (460) | 95.47 |
Metric parameters were calculated applying descriptive statistics. P values for pairwise comparison vs. no graft material were calculated in accordance to Kaplan and Meier using log-rank test.
Fig. 4Kaplan-Meier implant survival curves for bone and bone substitutes