Literature DB >> 27908151

Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.

Paolo Farace1, Roberto Righetto1, Sylvain Deffet2, Arturs Meijers3, Francois Vander Stappen3.   

Abstract

PURPOSE: To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping.
METHODS: Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45 × 45 mm2 field-of-view) of 9 × 9 spots capable of crossing the phantoms (210 MeV). The exit beam was collected by a MLIC to sample the integral depth dose (IDDMLIC). PRs of an electron-density and of a head phantom were acquired by moving the couch to obtain multiple 45 × 45 mm2 frames. To map the corresponding range errors, the two-dimensional set of IDDMLIC was compared with (i) the integral depth dose computed by the treatment planning system (TPS) by both analytic (IDDTPS) and Monte Carlo (IDDMC) algorithms in a volume of water simulating the MLIC at the CT, and (ii) the integral depth dose directly computed by a simple ray-tracing algorithm (IDDdirect) through the same CT data. The exact spatial position of the spot pattern was numerically adjusted testing different in-plane positions and selecting the one that minimized the range differences between IDDdirect and IDDMLIC.
RESULTS: Range error mapping was feasible by both the TPS and the ray-tracing methods, but very sensitive to even small misalignments. In homogeneous regions, the range errors computed by the direct ray-tracing algorithm matched the results obtained by both the analytic and the Monte Carlo algorithms. In both phantoms, lateral heterogeneities were better modeled by the ray-tracing and the Monte Carlo algorithms than by the analytic TPS computation. Accordingly, when the pencil beam crossed lateral heterogeneities, the range errors mapped by the direct algorithm matched better the Monte Carlo maps than those obtained by the analytic algorithm. Finally, the simplicity of the ray-tracing algorithm allowed to implement a prototype procedure for automated spatial alignment.
CONCLUSIONS: The ray-tracing algorithm can reliably replace the TPS method in MLIC PR for in vivo range verification and it can be a key component to develop software tools for spatial alignment and correction of CT calibration.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27908151     DOI: 10.1118/1.4966703

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

Review 1.  Status and innovations in pre-treatment CT imaging for proton therapy.

Authors:  Patrick Wohlfahrt; Christian Richter
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

2.  Inter-centre variability of CT-based stopping-power prediction in particle therapy: Survey-based evaluation.

Authors:  Vicki T Taasti; Christian Bäumer; Christina V Dahlgren; Amanda J Deisher; Malte Ellerbrock; Jeffrey Free; Joanna Gora; Anna Kozera; Antony J Lomax; Ludovic De Marzi; Silvia Molinelli; Boon-Keng Kevin Teo; Patrick Wohlfahrt; Jørgen B B Petersen; Ludvig P Muren; David C Hansen; Christian Richter
Journal:  Phys Imaging Radiat Oncol       Date:  2018-04-30

3.  Clinical suitability of deep learning based synthetic CTs for adaptive proton therapy of lung cancer.

Authors:  Adrian Thummerer; Carmen Seller Oria; Paolo Zaffino; Arturs Meijers; Gabriel Guterres Marmitt; Robin Wijsman; Joao Seco; Johannes Albertus Langendijk; Antje-Christin Knopf; Maria Francesca Spadea; Stefan Both
Journal:  Med Phys       Date:  2021-11-16       Impact factor: 4.506

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.