Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry by iDXA to measure human body composition.

K L Marlatt1, F L Greenway1, E Ravussin1.   

Abstract

Comparison of percent fat mass across different body composition analysis devices is important given variation in technology accuracy and precision, as well as the growing need for cross-validation of devices often applied across longitudinal studies. We compared EchoMRI-AH and Lunar iDXA quantification of percent body fat (PBF) in 84 adults (43M, 41F), with the mean age 39.7±15.9 years and body mass index (BMI) 26.2±5.3 kg/m2. PBF correlated strongly between devices (r>0.95, P<0.0001). A prediction equation was derived in half of the subjects, and the other half were used to cross-validate the proposed equation (EchoMRI-AH PBF=[(0.94 × iDXA PBF)+(0.14 × Age)+(3.3 × Female)-8.83). The mean PBF difference (predicted-measured) in the validation group was not different from 0 (diff=0.27%, 95% confidence interval: -0.42-0.96, P=0.430). Bland-Altman plots showed a bias with higher measured PBF on EchoMRI-AH versus iDXA in all 84 subjects (β=0.13, P<0.0001). The proposed prediction equation was valid in our cross-validation sample, and it has the potential to be applied across multicenter studies.

Entities:  

Mesh:

Year:  2016        PMID: 27901030      PMCID: PMC5382104          DOI: 10.1038/ejcn.2016.236

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  6 in total

1.  Quantitative magnetic resonance fat measurements in humans correlate with established methods but are biased.

Authors:  Dympna Gallagher; John C Thornton; Qing He; Jack Wang; Wen Yu; Thomas E Bradstreet; Joanne Burke; Steven B Heymsfield; Veronica M Rivas; Rhonda Kaufman
Journal:  Obesity (Silver Spring)       Date:  2010-05-06       Impact factor: 5.002

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Measurement of visceral adipose tissue by DXA combined with anthropometry in obese humans.

Authors:  E Bertin; C Marcus; J C Ruiz; J P Eschard; M Leutenegger
Journal:  Int J Obes Relat Metab Disord       Date:  2000-03

4.  Quantitative magnetic resonance (QMR) method for bone and whole-body-composition analysis.

Authors:  Gersh Z Taicher; Frank C Tinsley; Arcady Reiderman; Mark L Heiman
Journal:  Anal Bioanal Chem       Date:  2003-09-16       Impact factor: 4.142

5.  Validation of a quantitative magnetic resonance method for measuring human body composition.

Authors:  Antonella Napolitano; Sam R Miller; Peter R Murgatroyd; W Andrew Coward; Antony Wright; Nick Finer; Tjerk W De Bruin; Edward T Bullmore; Derek J Nunez
Journal:  Obesity (Silver Spring)       Date:  2008-01       Impact factor: 5.002

6.  Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition.

Authors:  J E Galgani; S R Smith; E Ravussin
Journal:  Int J Obes (Lond)       Date:  2011-01-11       Impact factor: 5.095

  6 in total
  1 in total

1.  Dual Energy X-ray Absorptiometry (DEXA) as a longitudinal outcome measure of cancer-related muscle wasting in mice.

Authors:  Calvin L Cole; Christopher A Beck; Deja Robinson; Jian Ye; Bradley Mills; Scott A Gerber; Edward M Schwarz; David Linehan
Journal:  PLoS One       Date:  2020-06-19       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.