Literature DB >> 27899542

Pulse Oximetry: Beyond SpO2.

Dean R Hess1.   

Abstract

Newer pulse oximetry technology is available that uses multiple wavelengths of light and is thereby able to measure more than 2 forms of hemoglobin, including carboxyhemoglobin (SpCO), methemoglobin (SpMet), and total hemoglobin (SpHb). Several studies have shown relatively low bias, but poor precision, for SpCO compared with HbCO. Evaluations of SpMet have been conducted primarily in normal subjects. Clinical evaluations of SpHb suggest that it might not yet be accurate enough to make transfusion decisions. Respiratory waveform variability of the pulse oximeter plethysmogram might be useful to assess pulsus paradoxus in patients with airway obstruction; it might also be used to measure the breathing frequency. The change in pulse pressure over the respiratory cycle has been used to assess fluid responsiveness in mechanically ventilated patients, and similarly, the pulse oximetry plethysmogram waveform amplitude variability might be used to assess fluid responsiveness. However, there are limitations to this approach, and it remains to be determined how well it can be applied clinically using existing pulse oximetry technology. The pulse oximeter signal is probably useful for applications beyond SpO2 However, the current technology is not mature, and improvements are necessary. With technology improvements, the use of pulse oximetry to detect SpCO, SpMet, SpHb, pulsus paradoxus, breathing frequency, and fluid responsiveness is likely to improve in the future.
Copyright © 2016 by Daedalus Enterprises.

Entities:  

Keywords:  breathing frequency; carboxyhemoglobin; fluid responsiveness; methemoglobin; oxygen saturation; pulse oximetry; pulsus paradoxus

Mesh:

Substances:

Year:  2016        PMID: 27899542     DOI: 10.4187/respcare.05208

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  3 in total

1.  Development of Low-Cost and Portable Pulse Oximeter Device with Improved Accuracy and Accessibility.

Authors:  Hundessa Daba Nemomssa; Hakkins Raj
Journal:  Med Devices (Auckl)       Date:  2022-05-05

2.  Racial Bias in Pulse Oximetry Measurement Among Patients About to Undergo Extracorporeal Membrane Oxygenation in 2019-2020: A Retrospective Cohort Study.

Authors:  Valeria S M Valbuena; Ryan P Barbaro; Dru Claar; Thomas S Valley; Robert P Dickson; Steven E Gay; Michael W Sjoding; Theodore J Iwashyna
Journal:  Chest       Date:  2021-09-27       Impact factor: 10.262

3.  Is pulse oximeter a reliable tool for non-critically ill patients with COVID-19?

Authors:  Aslıhan Gürün Kaya; Miraç Öz; İrem Akdemir Kalkan; Ezgi Gülten; Güle Çınar; Alpay Azap; Akın Kaya
Journal:  Int J Clin Pract       Date:  2021-10-21       Impact factor: 3.149