Literature DB >> 27892421

Screening for atrial fibrillation during influenza vaccinations by primary care nurses using a smartphone electrocardiograph (iECG): A feasibility study.

Jessica Orchard1,2, Nicole Lowres3, S Ben Freedman2,4,5,6, Laila Ladak3, William Lee7, Nicholas Zwar8, David Peiris9, Yasith Kamaladasa2, Jialin Li3, Lis Neubeck3,10,11.   

Abstract

BACKGROUND: People with unknown atrial fibrillation (AF), who are often asymptomatic, have a substantially increased risk of stroke. Although recommended in European guidelines, AF screening is not routinely performed. Screening at the time of influenza vaccination presents an ideal opportunity to detect AF in large numbers in a primary care medical setting, with an existing annual recall system for patients aged ≥65 years.
DESIGN: Cross-sectional pilot study of handheld smartphone electrocardiogram (iECG) screening to identify unknown AF.
METHODS: General practices in Sydney, Australia, were recruited during the influenza-vaccination period of April-June 2015. Practice nurses screened patients aged ≥65 years with a 30-second iECG, which has a validated algorithm for detecting AF in real time. In order to confirm the accuracy of the algorithm, two research cardiologists reviewed de-identified iECGs. In order to explore barriers and enablers, semi-structured interviews were conducted with selected nurses, practice managers and general practitioners.
RESULTS: Five general practices were recruited, and 973/2476 (39%) patients attending influenza vaccination were screened. Screening took an average of 5 minutes (range 1.5-10 minutes); however, abnormal iECGs required additional time. Newly identified AF was found in 8/973 patients (0.8%). The sensitivity of the iECG automated algorithm was 95% (95% confidence interval: 83-99%) and the specificity was 99% (95% confidence interval: 98-100%). Screening by practice nurses was well accepted by practice staff. Key enablers were the confidence and competence of nurses and a 'designated champion' to lead screening at the practice. Barriers were practice specific, and mainly related to staff time and funding.
CONCLUSIONS: Screening with iECG during influenza vaccination by primary care nurses is feasible and well accepted by practice staff. Addressing barriers is likely to increase uptake. © The European Society of Cardiology 2016.

Entities:  

Keywords:  Atrial fibrillation; flu vaccination; practice nurses; screening; stroke prevention

Mesh:

Substances:

Year:  2016        PMID: 27892421     DOI: 10.1177/2047487316670255

Source DB:  PubMed          Journal:  Eur J Prev Cardiol        ISSN: 2047-4873            Impact factor:   7.804


  31 in total

Review 1.  Digital health solutions in the screening of subclinical atrial fibrillation.

Authors:  Sebastian König; Andreas Bollmann; Gerhard Hindricks
Journal:  Herz       Date:  2021-06-04       Impact factor: 1.443

2.  Lead-I ECG for detecting atrial fibrillation in patients with an irregular pulse using single time point testing: a systematic review and economic evaluation.

Authors:  Rui Duarte; Angela Stainthorpe; Janette Greenhalgh; Marty Richardson; Sarah Nevitt; James Mahon; Eleanor Kotas; Angela Boland; Howard Thom; Tom Marshall; Mark Hall; Yemisi Takwoingi
Journal:  Health Technol Assess       Date:  2020-01       Impact factor: 4.014

3.  Continuous mHealth Patch Monitoring for the Algorithm-Based Detection of Atrial Fibrillation: Feasibility and Diagnostic Accuracy Study.

Authors:  Jari Halonen; Tero J Martikainen; Onni E Santala; Jukka A Lipponen; Helena Jäntti; Tuomas T Rissanen; Mika P Tarvainen; Tomi P Laitinen; Tiina M Laitinen; Maaret Castrén; Eemu-Samuli Väliaho; Olli A Rantula; Noora S Naukkarinen; Juha E K Hartikainen
Journal:  JMIR Cardio       Date:  2022-06-21

4.  Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care.

Authors:  Jelle C L Himmelreich; Evert P M Karregat; Wim A M Lucassen; Henk C P M van Weert; Joris R de Groot; M Louis Handoko; Robin Nijveldt; Ralf E Harskamp
Journal:  Ann Fam Med       Date:  2019-09       Impact factor: 5.166

5.  Genetic Predisposition, Clinical Risk Factor Burden, and Lifetime Risk of Atrial Fibrillation.

Authors:  Lu-Chen Weng; Sarah R Preis; Olivia L Hulme; Martin G Larson; Seung Hoan Choi; Biqi Wang; Ludovic Trinquart; David D McManus; Laila Staerk; Honghuang Lin; Kathryn L Lunetta; Patrick T Ellinor; Emelia J Benjamin; Steven A Lubitz
Journal:  Circulation       Date:  2017-11-12       Impact factor: 29.690

6.  Evaluating the Utility of mHealth ECG Heart Monitoring for the Detection and Management of Atrial Fibrillation in Clinical Practice.

Authors:  Kathleen T Hickey; Angelo B Biviano; Hasan Garan; Robert R Sciacca; Teresa Riga; Kate Warren; Ashton P Frulla; Nicole R Hauser; Daniel Y Wang; William Whang
Journal:  J Atr Fibrillation       Date:  2017-02-28

Review 7.  Research Priorities in Atrial Fibrillation Screening: A Report From a National Heart, Lung, and Blood Institute Virtual Workshop.

Authors:  Emelia J Benjamin; Alan S Go; Patrice Desvigne-Nickens; Christopher D Anderson; Barbara Casadei; Lin Y Chen; Harry J G M Crijns; Ben Freedman; Mellanie True Hills; Jeff S Healey; Hooman Kamel; Dong-Yun Kim; Mark S Link; Renato D Lopes; Steven A Lubitz; David D McManus; Peter A Noseworthy; Marco V Perez; Jonathan P Piccini; Renate B Schnabel; Daniel E Singer; Robert G Tieleman; Mintu P Turakhia; Isabelle C Van Gelder; Lawton S Cooper; Sana M Al-Khatib
Journal:  Circulation       Date:  2021-01-25       Impact factor: 29.690

Review 8.  Impact of Mobile Health Devices for the Detection of Atrial Fibrillation: Systematic Review.

Authors:  Tom E Biersteker; Martin J Schalij; Roderick W Treskes
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-28       Impact factor: 4.773

Review 9.  Screening for Atrial Fibrillation in Community and Primary CareSettings: A Scoping Review.

Authors:  Emma Canty; Claire MacGilchrist; Wael Tawfick; Caroline McIntosh
Journal:  J Atr Fibrillation       Date:  2021-02-28

10.  The Auxiliary Diagnostic Value of a Novel Wearable Electrocardiogram-Recording System for Arrhythmia Detection: Diagnostic Trial.

Authors:  Shaomin Zhang; Hong Xian; Yi Chen; Yue Liao; Nan Zhang; Xinyu Guo; Ming Yang; Jinhui Wu
Journal:  Front Med (Lausanne)       Date:  2021-06-24
View more