Computational fluid analysis of symptomatic chronic type B aortic dissections managed with the Streamliner Multilayer Flow Modulator.

Florian Stefanov1, Sherif Sultan2, Liam Morris1, Ala Elhelali3, Edel P Kavanagh3, Violet Lundon4, Mohamed Sultan4, Niamh Hynes3.   

Abstract

OBJECTIVE: Managing symptomatic chronic type B aortic dissection (SCTBAD) by the Streamliner Multilayer Flow Modulator (SMFM) stent (Cardiatis, Isnes, Belgium) is akin to provisional structural support to induce complete attachment of the dissection flap, but with the ability of aortic remolding. This study investigated the SMFM's capability to enact healing of SCTBAD.
METHODS: Clinical data for 12 cases comprising preoperative and postoperative treatment of SCTBAD were obtained from a multicenter database hosted by the Multilayer Flow Modulator Global Registry, Ireland. A biomechanical analysis, by means of computational fluid dynamics modeling, of the hemodynamic effects and branch patency associated with the use of the SMFM was performed for all cases. The mean length of the dissections was 30.23 ± 13.3 cm. There were 30 SMFMs used, which covered 69 aortic branches.
RESULTS: At 1-year follow-up, the true lumen volume increased from 175.74 ± 98.83 cm3 to 209.87 ± 128.79 cm3; the false lumen decreased from 135.2 ± 92.03 cm3 to 123.19 ± 110.11 cm3. The false lumen index decreased from 0.29 ± 0.13 (preoperatively) to 0.21 ± 0.15 (postoperatively). The primary SMFM treatment of SCTBAD increased carotid perfusion by 35% ± 21% (P = .0216) and suprarenal perfusion by 78% ± 32% (P = .001). The wall pressure distribution blended along the newly enlarged true lumen, whereas the false lumen wall pressure decreased by 6.23% ± 4.81% for the primary group (cases 1-7) and by 3.84% ± 2.59% for the secondary group (cases 8-12).
CONCLUSIONS: SMFM reduces the false lumen wall pressure through flow modulation. It preserves patency of all branches, minimizing the incidence of short-term complications. The SMFM is a valuable option in managing primary SCTBAD, without midterm complications.
Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2016        PMID: 27889286     DOI: 10.1016/j.jvs.2016.07.135

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  9 in total

1.  Multilayer flow modulator enhances vital organ perfusion in patients with type B aortic dissection.

Authors:  Farhad Rikhtegar Nezami; Lambros S Athanasiou; Junedh M Amrute; Elazer R Edelman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-08-10       Impact factor: 4.733

2.  Multilayer stents affect the final diameter of aortic aneurysms and maintain renal artery patency for a short time in a swine experimental model.

Authors:  Anna Paula Weinhardt Baptista-Strazzi; Ricardo Aun; Igor Rafael Sincos; Allana M Tobita; Maria Fernanda Cassino Portugal; Vitória Penido de Paula; Oskar Kaufmann; Nelson Wolosker
Journal:  Clinics (Sao Paulo)       Date:  2021-05-21       Impact factor: 2.365

3.  Favorable remodeling after hybrid arch debranching and modified provisional extension to induce complete attachment technique in type a aortic dissection: A case report.

Authors:  Arkadiusz Kazimierczak; Tomasz Jedrzejczak; Paweł Rynio; Szymon Waligórski
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

4.  Endovascular repair during complex thoracic aortic dissection using a micropore stent graft: Midterm follow-up clinical outcomes.

Authors:  Zhe Wang; Cheng Wang; Fenghe Li; Yu Zhao
Journal:  Catheter Cardiovasc Interv       Date:  2019-08-13       Impact factor: 2.692

5.  Proximal true lumen collapse in a chronic type B aortic dissection patient: A case report.

Authors:  Li Zhang; Wei-Kang Guan; Hua-Ping Wu; Xiang Li; Kai-Ping Lv; Cun-Liang Zeng; Huan-Huan Song; Qian-Ling Ye
Journal:  World J Clin Cases       Date:  2021-12-06       Impact factor: 1.337

6.  An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection.

Authors:  Liam Morris; Paul Tierney; Niamh Hynes; Sherif Sultan
Journal:  Front Cardiovasc Med       Date:  2022-03-17

Review 7.  The contemporary design of endovascular aneurysm stent-graft materials: PTFE versus polyester.

Authors:  Niamh Hynes; Yogesh Acharya; Sherif Sultan
Journal:  Front Surg       Date:  2022-08-16

Review 8.  TEVAR and EVAR, the unknown knowns of the cardiovascular hemodynamics; and the immediate and long-term consequences of fabric material on major adverse clinical outcome.

Authors:  Sherif Sultan; Yogesh Acharya; Osama Soliman; Juan Carlos Parodi; Niamh Hynes
Journal:  Front Surg       Date:  2022-08-30

9.  One-Year Single-Center Results of the Multilayer Flow Modulator Stents for the Treatment of Type B Aortic Dissection.

Authors:  Victor S Costache; Jorn P Meekel; Andreea Costache; Tatiana Melnic; Cristian Bucurenciu; Anca Chitic; Gabriela Candea; Crina Solomon; Kak K Yeung
Journal:  J Endovasc Ther       Date:  2020-09-01       Impact factor: 3.487