Literature DB >> 27887874

Clinical and radiographic outcome of revision surgery of radial head prostheses: midterm results in 16 patients.

Jetske Viveen1, Izaäk F Kodde2, Koen L M Koenraadt3, Annechien Beumer4, Bertram The4, Denise Eygendaal2.   

Abstract

BACKGROUND: Little is known about revision surgery of radial head arthroplasty. The aim of this study was to report on the clinical and radiographic outcome of revision arthroplasty of the elbow with a bipolar metallic radial head prosthesis.
METHODS: Between 2006 and 2013, we used either a press-fit or cemented RHS bipolar radial head prosthesis for revision surgery of radial head arthroplasty in 16 patients. Patients were prospectively enrolled in the study. Differences in outcome parameters before and after revision surgery were compared.
RESULTS: At a mean follow-up of 75 months (range, 36-116 months), none of the revised radial head prostheses needed a second revision. None of the stems showed radiographic signs of loosening. In 1 patient the head was dissociated from the prosthesis. The average flexion-extension arc was 127° (range, 105°-140°), and the average pronation-supination arc was 138° (range, 90°-160°). Stability scores improved after revision surgery, resulting in 13 stable elbows (P = .01). In 8 patients the Oxford Elbow Score was between 37 and 48 points. The percentage of patients with either good or excellent results according to the Mayo Elbow Performance Score was 63%. The mean score on the EQ-5D (EuroQol Five Dimensions) was 80 (range, 63-100), and the visual analog scale scores both for pain at rest and for pain with activity improved to 3 (range, 0-9) and 4 (range, 0-9), respectively (P < .001). All but 1 patient was satisfied with the results of the revision procedure.
CONCLUSION: The clinical and radiographic outcomes of revision surgery of a radial head prostheses are favorable.
Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Elbow; arthroplasty; bipolar; outcome; prosthesis; radial head; revision

Mesh:

Year:  2016        PMID: 27887874     DOI: 10.1016/j.jse.2016.09.047

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  4 in total

1.  The Radial Floating Cup radial head prosthesis to treat radial head fractures: functional and radiographic results after more than 12 years of mean follow-up.

Authors:  Baptiste Montbarbon; Hoel Letissier; Frédéric Dubrana; Dominique Le Nen; Rémi Di Francia
Journal:  Arch Orthop Trauma Surg       Date:  2020-07-25       Impact factor: 3.067

2.  In vitro comparison of wear characteristics of PyroCarbon and metal on bone: Shoulder hemiarthroplasty.

Authors:  Jerome J Klawitter; Jason Patton; Robert More; Noel Peter; Evgeny Podnos; Mark Ross
Journal:  Shoulder Elbow       Date:  2018-09-11

Review 3.  Why does radial head arthroplasty fail today? A systematic review of recent literature.

Authors:  Jetske Viveen; Izaak F Kodde; Andras Heijink; Koen L M Koenraadt; Michel P J van den Bekerom; Denise Eygendaal
Journal:  EFORT Open Rev       Date:  2020-01-28

Review 4.  Radial head arthroplasty: fixed-stem implants are not all equal-a systematic review and meta-analysis.

Authors:  Christopher Vannabouathong; Nainika Venugopal; George S Athwal; Jaydeep Moro; Mohit Bhandari
Journal:  JSES Int       Date:  2020-02-29
  4 in total