Literature DB >> 27887871

Radiographic results of augmented all-polyethylene glenoids in the presence of posterior glenoid bone loss during total shoulder arthroplasty.

Scott P Stephens1, Edwin E Spencer2, Michael A Wirth3.   

Abstract

BACKGROUND: Chronic osteoarthritis can result in glenohumeral subluxation and loss of posterior glenoid bone. This can alter normal glenohumeral biomechanics and affect the stress placed on the glenoid implant after total shoulder arthroplasty. This study evaluated the clinical and radiographic results of an augmented all-polyethylene glenoid for the treatment of glenoid osteoarthritis in the presence of posterior glenoid bone loss and determined whether any failures or complications occurred with short-term follow-up.
METHODS: During a 2-year period, 21 patients were treated with an augmented glenoid for an index diagnosis of osteoarthritis with a biconcave glenoid and average posterior glenoid bone loss of 4.7 mm. Clinical outcomes were recorded for the American Shoulder and Elbow Surgeons Shoulder Assessment, Simple Shoulder Test, and active motion. Radiographic analysis included glenoid version, humeral head subluxation, component seating, ingrowth, and loosening.
RESULTS: Significant improvements were demonstrated for American Shoulder and Elbow Surgeons Shoulder Assessment (52.3), Simple Shoulder Test (8.1), forward flexion (50°), external rotation (32°), and pain. Radiographic improvements were found for glenoid version (12°), humeral scapular alignment (23%), and humeral glenoid alignment (8%). Central peg ingrowth was demonstrated in all patients, and complete component seating was achieved in 19 patients. No complications were encountered, and no clinical or radiographic failures were identified.
CONCLUSION: Augmented polyethylene glenoid components demonstrated improved clinical outcome, without implant failure or complications, during short-term follow-up.
Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Augmented glenoid; anchor peg glenoid; biconcave glenoid; glenoid loosening; glenoid retroversion; posterior glenoid bone loss; shoulder osteoarthritis; total shoulder arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27887871     DOI: 10.1016/j.jse.2016.09.053

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  12 in total

1.  One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers.

Authors:  Frederick A Matsen; Joseph P Iannotti; R Sean Churchill; Lieven De Wilde; T Bradley Edwards; Matthew C Evans; Edward V Fehringer; Gordon I Groh; James D Kelly; Christopher M Kilian; Giovanni Merolla; Tom R Norris; Giuseppe Porcellini; Edwin E Spencer; Anne Vidil; Michael A Wirth; Stacy M Russ; Moni Neradilek; Jeremy S Somerson
Journal:  Int Orthop       Date:  2018-12-03       Impact factor: 3.075

Review 2.  Journey of the glenoid in anatomic total shoulder replacement.

Authors:  Alessandro Castagna; Raffaele Garofalo
Journal:  Shoulder Elbow       Date:  2018-08-01

3.  Risk of Perforation Is High During Corrective Reaming of Retroverted Glenoids: A Computer Simulation Study.

Authors:  Alexander W Aleem; Nathan D Orvets; Brendan C Patterson; Aaron M Chamberlain; Jay D Keener
Journal:  Clin Orthop Relat Res       Date:  2018-08       Impact factor: 4.176

Review 4.  Classifications in Brief: Walch Classification of Primary Glenohumeral Osteoarthritis.

Authors:  Kiet V Vo; Daniel J Hackett; Albert O Gee; Jason E Hsu
Journal:  Clin Orthop Relat Res       Date:  2017-03-17       Impact factor: 4.176

5.  Does Postoperative Glenoid Retroversion Affect the 2-Year Clinical and Radiographic Outcomes for Total Shoulder Arthroplasty?

Authors:  Benjamin C Service; Jason E Hsu; Jeremy S Somerson; Stacy M Russ; Frederick A Matsen
Journal:  Clin Orthop Relat Res       Date:  2017-07-05       Impact factor: 4.176

6.  Glenoid retroversion does not impact clinical outcomes or implant survivorship after total shoulder arthroplasty with minimal, noncorrective reaming.

Authors:  Travis J Dekker; W Jeffrey Grantham; Lucca Lacheta; Brandon T Goldenberg; Rony-Orijit Dey Hazra; Dylan R Rakowski; Grant J Dornan; Marilee P Horan; Peter J Millett
Journal:  JSES Int       Date:  2022-03-18

Review 7.  Innovations in Shoulder Arthroplasty.

Authors:  Nels Leafblad; Elise Asghar; Robert Z Tashjian
Journal:  J Clin Med       Date:  2022-05-16       Impact factor: 4.964

8.  Does posterior half-wedge augmented glenoid restore version and alignment in total shoulder arthroplasty for the B2 glenoid?

Authors:  Abhishek Kumar Das; Andrew C Wright; Jagwant Singh; Puneet Monga
Journal:  J Clin Orthop Trauma       Date:  2020-02-14

9.  Stepped Augmented Glenoid Component in Anatomic Total Shoulder Arthroplasty for B2 and B3 Glenoid Pathology: A Study of Early Outcomes.

Authors:  Joseph P Iannotti; Bong-Jae Jun; Kathleen A Derwin; Eric T Ricchetti
Journal:  J Bone Joint Surg Am       Date:  2021-10-06       Impact factor: 6.558

10.  Anatomic Total Shoulder Arthroplasty with All-Polyethylene Glenoid Component for Primary Osteoarthritis with Glenoid Deficiencies.

Authors:  Frederick A Matsen; Anastasia J Whitson; Jeremy S Somerson; Jason E Hsu
Journal:  JB JS Open Access       Date:  2020-11-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.