Literature DB >> 2788669

Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography.

S R Bergmann1, P Herrero, J Markham, C J Weinheimer, M N Walsh.   

Abstract

Noninvasive measurement of myocardial blood flow in absolute terms (i.e., milliliters per gram per min) has been difficult to accomplish despite the intrinsically quantitative power of positron emission tomography because of the nonphysiologic nature of tracers that have been employed conventionally as well as the limited spatial resolution of currently available instruments. It was previously demonstrated that myocardial blood flow in animals can be quantitated accurately with the diffusible tracer oxygen-15-labeled water (H2(15)O) when the arterial input function and myocardial radiotracer concentration were measured directly. To extend the approach for completely noninvasive measurement of blood flow, a parameter estimation procedure was developed whereby effects of limited tomographic spatial resolution and cardiac motion were compensated for within the operational flow model. In validation studies in 18 dogs, myocardial blood flow measured with positron emission tomography after intravenously administered H2(15)O correlated closely with flow measured with concomitantly administered radiolabeled microspheres over the range of 0.29 to 5.04 ml/g per min (r = 0.95). Although regional ischemia was clearly identifiable tomographically, absolute flow could not be determined accurately in ischemic regions in four dogs because of poor count statistics related to wall thinning. Subsequently, myocardial blood flow was measured in 11 normal human subjects. Flow was homogeneous throughout the myocardium, averaged 0.90 +/- 0.22 ml/g per min at rest and increased to 3.55 +/- 1.15 ml/g per min after intravenous administration of dipyridamole. Therefore, positron emission tomography with H2 15O and the approach developed permits noninvasive measurement of myocardial blood flow in absolute terms in humans and should facilitate objective assessment of interventions designed to enhance nutritive perfusion.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2788669     DOI: 10.1016/0735-1097(89)90105-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  101 in total

Review 1.  Tracer kinetic modeling in nuclear cardiology.

Authors:  T R DeGrado; S R Bergmann; C K Ng; D M Raffel
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

Review 2.  Positron emission tomography in paediatric cardiology.

Authors:  R M Quinlivan; R O Robinson; M N Maisey
Journal:  Arch Dis Child       Date:  1998-12       Impact factor: 3.791

3.  T(2) preparation method for measuring hyperemic myocardial O(2) consumption: in vivo validation by positron emission tomography.

Authors:  Kyle S McCommis; Robert O'Connor; Dana R Abendschein; David Muccigrosso; Robert J Gropler; Jie Zheng
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

Review 4.  The value of quantitative myocardial perfusion imaging with positron emission tomography in coronary artery disease.

Authors:  W Wijns; P G Camici
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

Review 5.  The perfusable tissue index: a marker of myocardial viability.

Authors:  Paul Knaapen; Ronald Boellaard; Marco J W Götte; Arno P van der Weerdt; Cees A Visser; Adriaan A Lammertsma; Frans C Visser
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

Review 6.  Myocardial perfusion imaging agents: SPECT and PET.

Authors:  George A Beller; Steven R Bergmann
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

Review 7.  Skeletal Blood Flow in Bone Repair and Maintenance.

Authors:  Ryan E Tomlinson; Matthew J Silva
Journal:  Bone Res       Date:  2013-12-31       Impact factor: 13.567

8.  Myocardial blood flow: Putting it into clinical perspective.

Authors:  Thomas Hellmut Schindler
Journal:  J Nucl Cardiol       Date:  2015-12-28       Impact factor: 5.952

9.  Simplified quantification of PET myocardial blood flow: The need for technical standardization.

Authors:  Jonathan B Moody; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2018-11-05       Impact factor: 5.952

10.  Direct comparison between 2-dimensional and 3-dimensional PET acquisition modes for myocardial blood flow absolute quantification with O-15 water and N-13 ammonia.

Authors:  Véronique Roelants; Anne Bol; Xavier Bernard; Ann Coppens; Jacques Melin; Bernhard Gerber; Jean-Louis Vanoverschelde
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.