Literature DB >> 27878783

Prediction of significant hyperbilirubinemia in term neonates by early non-invasive bilirubin measurement.

Manish Jain1, Akash Bang2, Anju Tiwari2, Shuchi Jain3.   

Abstract

BACKGROUND: Neonatal jaundice is a common problem. We evaluated the utility and best cut-off values of 24-and 48-hour transcutaneous bilirubin indices (TcBI) in predicting subsequent significant hyperbilirubinemia and evaluated various associated maternal and fetal risk factors.
METHODS: TcBI at 24 and 48 hours and serum bilirubin levels at 72 hours of age were obtained for healthy, term, appropriate for gestational age neonates. Neonates with prematurity, birth weight <2500 g, ABO or Rh incompatibility, onset of clinical jaundice <24 hours, clinical suspicion of septicemia, positive pressure ventilation at birth, admission in neonatal intensive care unit and contraindications for BiliChek were excluded. Twently-four and 48-hour TcB indices were assessed as predictors of subsequent hyperbilirubinemia, defined as serum bilirubin >17 mg/dL after 72 hours of life and various cut-offs, and were evaluated by calculating sensitivity, specificity and predictive values.
RESULTS: Of 500 newborns, 4.6% had significant hyperbilirubinemia, 27% had TcBI (mg/dL) <5 at 24 hours, and 27.4% had TcBI <8 at 48 hours. None of them had subsequent hyperbilirubinemia (100% negative predictive value). The percentage of newborns with subsequent hyperbilirubinemia increased from 3.4% to 13.2% as their 24-hour TcBI increased from 6 to above 9 mg/dL and from 4.2% to 7.4% as their 48-hour TcBI increased from 8 to above 11 mg/dL. The best cut-off value was TcBI (mg/dL) 7 (odd ratio=4.86, 95% confidence interval: 1.66-15.22) at 24 hours and 10 (odd ratio=2.87, 95% confidence interval: 1.04-8.29) at 48 hours. Area under the receiver operating characteristic curve for 24- and 48-hour measurements was 0.750 and 0.715, respectively. Maternal premature rupture of membranes, deep transverse arrest, post-date pregnancy, and fetal distress were significant risk factors for hyperbilirubinemia.
CONCLUSIONS: Twenty-four and 48-hour TcB indices are good predictors of subsequent hyperbilirubinemia. Twenty-four-hour TcBI had better predictive ability than 48-hour TcBI.

Entities:  

Keywords:  hyperbilirubinemia; neonate; transcutaneous bilirubin

Mesh:

Substances:

Year:  2016        PMID: 27878783     DOI: 10.1007/s12519-016-0067-1

Source DB:  PubMed          Journal:  World J Pediatr            Impact factor:   2.764


  26 in total

1.  Non-invasive estimation of total serum bilirubin by multi-wavelength spectral reflectance in neonates.

Authors:  R Lodha; A K Deorari; V Jatana; V K Paul
Journal:  Indian Pediatr       Date:  2000-07       Impact factor: 1.411

Review 2.  An evidence-based review of important issues concerning neonatal hyperbilirubinemia.

Authors:  Stanley Ip; Mei Chung; John Kulig; Rebecca O'Brien; Robert Sege; Stephan Glicken; M Jeffrey Maisels; Joseph Lau
Journal:  Pediatrics       Date:  2004-07       Impact factor: 7.124

3.  Transcutaneous bilirubin in predicting hyperbilirubinemia in term neonates.

Authors:  Y Ramesh Bhat; Amitha Rao
Journal:  Indian J Pediatr       Date:  2008-02       Impact factor: 1.967

4.  Prediction of hyperbilirubinaemia in the healthy term newborn.

Authors:  X Carbonell; F Botet; J Figueras; A Riu-Godó
Journal:  Acta Paediatr       Date:  2001-02       Impact factor: 2.299

5.  Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia.

Authors:  V K Bhutani; G R Gourley; S Adler; B Kreamer; C Dalin; L H Johnson
Journal:  Pediatrics       Date:  2000-08       Impact factor: 7.124

6.  Phototherapy use in jaundiced newborns in a large managed care organization: do clinicians adhere to the guideline?

Authors:  Lee R Atkinson; Gabriel J Escobar; John I Takayama; Thomas B Newman
Journal:  Pediatrics       Date:  2003-05       Impact factor: 7.124

7.  Transcutaneous bilirubin measurements in full-term infants.

Authors:  M J Maisels; S Conrad
Journal:  Pediatrics       Date:  1982-09       Impact factor: 7.124

8.  Assessment of a transcutaneous device in the evaluation of neonatal hyperbilirubinemia in a primarily Hispanic population.

Authors:  William D Engle; Gregory L Jackson; Dorothy Sendelbach; Denise Manning; William H Frawley
Journal:  Pediatrics       Date:  2002-07       Impact factor: 7.124

9.  Transcutaneous bilirubinometry in very low birthweight infants.

Authors:  L Karolyi; F Pohlandt; R Muche; A R Franz; W A Mihatsch
Journal:  Acta Paediatr       Date:  2004-07       Impact factor: 2.299

10.  Predictive ability of a predischarge hour-specific serum bilirubin for subsequent significant hyperbilirubinemia in healthy term and near-term newborns.

Authors:  V K Bhutani; L Johnson; E M Sivieri
Journal:  Pediatrics       Date:  1999-01       Impact factor: 7.124

View more
  3 in total

1.  Reproducibility of BiliCare™ Transcutaneus Bilirrubin Meter in Mexican Newborns.

Authors:  David Oldak; Gabriela García; Estela E Gonzalez; Enver Aillon; Juan C Falcon; Ernesto Ayala; Bernardo Oldak
Journal:  Int J Pediatr       Date:  2019-01-01

2.  Evaluation of a new transcutaneous bilirubinometer in newborn infants.

Authors:  Mikael Norman; Hüseyin Aytug; Hasan Basri Celebi
Journal:  Sci Rep       Date:  2022-04-07       Impact factor: 4.379

3.  The Detection of Early Reading Performance and Its Relationship with Biopsychosocial Risk Factors in the Study of Learning Difficulties.

Authors:  Cristina Quiroga Bernardos; Santiago López Gómez; Patricia María Iglesias Souto; Rosa María Rivas Torres; Eva María Taboada Ares
Journal:  Eur J Investig Health Psychol Educ       Date:  2022-08-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.