Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia.

V K Bhutani1, G R Gourley, S Adler, B Kreamer, C Dalin, L H Johnson.   

Abstract

BACKGROUND: Jaundice in near-term and term newborns is a frequent diagnosis that may prompt hospital readmission in the first postnatal week. Hyperbilirubinemia, when excessive, can lead to potentially irreversible bilirubin-induced neurotoxicity. Predischarge risk assessment (at 24-72 hours of age) for subsequent excessive hyperbilirubinemia is feasible by a laboratory-based assay of total serum bilirubin (TSB). Hypothesis. Noninvasive, transcutaneous, point-of-care measurement of transcutaneous bilirubin (TcB) predischarge by multiwavelength spectral analysis, using a portable BiliCheck device (SpectRx Inc, Norcross, GA), is clinically equivalent to measurement of TSB in a diverse, multiracial term and near-term newborn population and predictive of subsequent hyperbilirubinemia.
METHODOLOGY: We evaluated a hand-held device that uses multiwavelength spectral reflectance analysis to measure TcB (BiliCheck). The study population (490 term and near-term newborns) was racially diverse (59.1% white, 29.5% black, 3.46% Hispanic, 4.48% Asian, and 3.46% other) and was evaluated at 2 separate institutions using multiple (11) devices. The postnatal age ranged from 12 to 98 hours and the ranges of birth weights and gestational ages were 2000 to 5665 g and 35 to 42 weeks, respectively. All transcutaneous evaluations were performed contemporaneously and paired with a heelstick TSB measurement. All TSB assays were performed by high performance liquid chromatography, as well as by diazo dichlorophenyldiazonium tetrafluoroborate techniques.
RESULTS: TSB values ranged from .2 to 18.2 mg/dL (mean +/- standard deviation: 7.65 +/- 3.35 mg/dL). The overall correlation of TSB (by high performance liquid chromatography technique) to TcB (by BiliCheck devices) was linear and statistically significant (r =.91; r(2) =.83; TcB =.84; TSB = +.75; standard error of regression line = 1.38; P <.001; n = 490 infants; 1788 samples). Similar regression statistics were evident in subset populations categorized by race (white: r =.91 [n = 289 infants]; black: r =.91 [n = 145 infants]) as well as by gestation (term: r =. 91 [n = 1625 samples]; near-term: r =.89 [n = 163 samples]). Intradevice precision was determined to be.59 mg/dL (2-3 measurements per infant with 1 device; n = 210 infants; 510 samples in a separate subset). Interdevice evaluation of 11 devices determined the precision to be.68 mg/dL (2-4 devices used for measurements per patient). In 23 of 419 of the study population infants who were in the 24- to 72-hour age range, the predischarge TSB values designated them to be at high risk for subsequent excessive hyperbilirubinemia (above the 95th percentile track on the hour-specific bilirubin nomogram). For these infants, the paired BiliCheck TcB values were all above the 75th percentile track (negative predictive value = 100%; positive predictive value = 32. 86%; sensitivity = 100%; specificity = 88.1%; likelihood ratio = 8. 43).
CONCLUSIONS: Our data demonstrate the accuracy and reproducibility of the predischarge BiliCheck measurements in term and near-term newborn infants of diverse races and ethnicities. Infants with predischarge BiliCheck values above the 75th percentile of hour-specific TSB values on the bilirubin nomogram may be considered to be at high risk for subsequent excessive hyperbilirubinemia. Further studies are needed to assess the efficacy of this technique in preterm infants, those undergoing phototherapy, and those with TSB values of >/=15 mg/dL (>/=256 micromol/L).

Entities:  

Mesh:

Year:  2000        PMID: 10920173     DOI: 10.1542/peds.106.2.e17

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  45 in total

1.  Effect of metoclopramide administration to mothers on neonatal bilirubin and maternal prolactin: a randomized, controlled, clinical trial.

Authors:  Shirin Osouli Tabrizi; Mojgan Mirghafourvand; Abdollah Jannat Dost; Sakineh Mohammad-Alizadeh-Charandabi; Yousef Javadzadeh; Robabe Seyedi
Journal:  World J Pediatr       Date:  2018-12-05       Impact factor: 2.764

2.  Transcutaneous bilirubin in predicting hyperbilirubinemia in term neonates.

Authors:  Y Ramesh Bhat; Amitha Rao
Journal:  Indian J Pediatr       Date:  2008-02       Impact factor: 1.967

3.  Estimation of bilirubin using BiliChektrade mark, a transcutaneous bilirubin measurement device: Effects of gestational age and use of phototherapy.

Authors:  Ka Jangaard; H Curtis; Rb Goldbloom
Journal:  Paediatr Child Health       Date:  2006-02       Impact factor: 2.253

4.  Transcutaneous bilirubinometry in neonates.

Authors:  Koravangattu Sankaran
Journal:  Paediatr Child Health       Date:  2006-02       Impact factor: 2.253

5.  Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns.

Authors:  C Greco; I F Iskander; D M Akmal; S Z El Houchi; D A Khairy; G Bedogni; R P Wennberg; C Tiribelli; C D Coda Zabetta
Journal:  J Perinatol       Date:  2017-06-15       Impact factor: 2.521

Review 6.  Prevention of kernicterus: new guidelines and the critical role of family physicians.

Authors:  Elizabeth Shaw; Danielle Grenier
Journal:  Can Fam Physician       Date:  2008-04       Impact factor: 3.275

7.  Accuracy of transcutaneous bilirubin measurement in newborns after phototherapy.

Authors:  L Casnocha Lucanova; K Matasova; M Zibolen; P Krcho
Journal:  J Perinatol       Date:  2016-06-09       Impact factor: 2.521

Review 8.  Managing the jaundiced newborn: a persistent challenge.

Authors:  M Jeffrey Maisels
Journal:  CMAJ       Date:  2014-11-10       Impact factor: 8.262

9.  Neonatal jaundice and stool production in breast- or formula-fed term infants.

Authors:  Hannah D Buiter; Sebastiaan S P Dijkstra; Rob F M Oude Elferink; Peter Bijster; Henk A Woltil; Henkjan J Verkade
Journal:  Eur J Pediatr       Date:  2007-07-10       Impact factor: 3.183

10.  Comparison of a new transcutaneous bilirubinometer (Bilimed) with serum bilirubin measurements in preterm and full-term infants.

Authors:  Tanja Karen; Hans Ulrich Bucher; Jean-Claude Fauchère
Journal:  BMC Pediatr       Date:  2009-11-12       Impact factor: 2.125

View more