Literature DB >> 27876280

Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance.

Robert Stanton1, Sally-Anne Wintour2, Crystal O Kean2.   

Abstract

OBJECTIVES: Smartphone applications are increasingly used by researchers, coaches, athletes and clinicians. The aim of this study was to examine the concurrent validity and intra-rater reliability of the smartphone-based application, MyJump, against laboratory-based force plate measurements.
DESIGN: Cross sectional study.
METHODS: Participants completed counter-movement jumps (CMJ) (n=29) and 30cm drop jumps (DJ) (n=27) on a force plate which were simultaneously recorded using MyJump. To assess concurrent validity, jump height, derived from flight time acquired from each device, was compared for each jump type. Intra-rater reliability was determined by replicating data analysis of MyJump recordings on two occasions separated by seven days.
RESULTS: CMJ and DJ heights derived from MyJump showed excellent agreement with the force plate (ICC values range from 0.991 for CMJ to 0.993) However mean DJ height from the force plate was significantly higher than MyJump (mean difference: 0.87cm, 95% CI: 0.69-1.04cm). Intra-rater reliability of MyJump for both CMJ and DJ was almost perfect (ICC values range from 0.997 for CMJ to 0.998 for DJ); however, mean CMJ and DJ jump height for Day 1 was significantly higher than Day 2 (CMJ: 0.43cm, 95% CI: 0.23-0.62cm); (DJ: 0.38cm, 95% CI: 0.23-0.53cm).
CONCLUSION: The present study finds MyJump to be a valid and highly reliable tool for researchers, coaches, athletes and clinicians; however, systematic bias should be considered when comparing MyJump outputs to other testing devices.
Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Jump height; Muscle power; Physical performance; Skill development; Strength

Mesh:

Year:  2016        PMID: 27876280     DOI: 10.1016/j.jsams.2016.09.016

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  9 in total

1.  When Jump Height is not a Good Indicator of Lower Limb Maximal Power Output: Theoretical Demonstration, Experimental Evidence and Practical Solutions.

Authors:  Jean-Benoit Morin; Pedro Jiménez-Reyes; Matt Brughelli; Pierre Samozino
Journal:  Sports Med       Date:  2019-07       Impact factor: 11.136

Review 2.  Outcome measures used in the smartphone applications for the management of low back pain: a systematic scoping review.

Authors:  Rachel Coe-O'Brien; Leonard Joseph; Raija Kuisma; Aatit Paungmali; Patraporn Sitilertpisan; Ubon Pirunsan
Journal:  Health Inf Sci Syst       Date:  2020-01-02

3.  Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study.

Authors:  Blanca De-la-Cruz-Torres; Irene Barrera-García-Martín; Mónica De la Cueva-Reguera; María Bravo-Aguilar; María Blanco-Morales; Emmanuel Navarro-Flores; Carlos Romero-Morales; Vanesa Abuín-Porras
Journal:  Medicina (Kaunas)       Date:  2020-04-16       Impact factor: 2.430

4.  Validity and Reliability of Mobile Applications for Assessing Strength, Power, Velocity, and Change-of-Direction: A Systematic Review.

Authors:  Rui Silva; Markel Rico-González; Ricardo Lima; Zeki Akyildiz; José Pino-Ortega; Filipe Manuel Clemente
Journal:  Sensors (Basel)       Date:  2021-04-08       Impact factor: 3.576

5.  Reliability of My Jump 2 Derived from Crouching and Standing Observation Heights.

Authors:  Jose M Jimenez-Olmedo; Basilio Pueo; Jose M Mossi; Lamberto Villalon-Gasch
Journal:  Int J Environ Res Public Health       Date:  2022-08-10       Impact factor: 4.614

6.  Effects of an experimental short-time high-intensity warm-up on explosive muscle strength performance in soccer players: A pilot study.

Authors:  Antonino Patti; Valerio Giustino; Norikazu Hirose; Giuseppe Messina; Stefania Cataldi; Giuseppe Grigoli; Alida Marchese; Giuseppe Mulè; Patrik Drid; Antonio Palma; Antonino Bianco
Journal:  Front Physiol       Date:  2022-08-25       Impact factor: 4.755

7.  The reliability of vertical jump tests between the Vertec and My Jump phone application.

Authors:  Vanessa R Yingling; Dimitri A Castro; Justin T Duong; Fiorella J Malpartida; Justin R Usher; Jenny O
Journal:  PeerJ       Date:  2018-04-20       Impact factor: 2.984

8.  Validity, Reliability, and Usefulness of My Jump 2 App for Measuring Vertical Jump in Primary School Children.

Authors:  Špela Bogataj; Maja Pajek; Vedran Hadžić; Slobodan Andrašić; Johnny Padulo; Nebojša Trajković
Journal:  Int J Environ Res Public Health       Date:  2020-05-25       Impact factor: 3.390

Review 9.  Trends Assessing Neuromuscular Fatigue in Team Sports: A Narrative Review.

Authors:  Claudia Alba-Jiménez; Daniel Moreno-Doutres; Javier Peña
Journal:  Sports (Basel)       Date:  2022-02-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.