Literature DB >> 27873208

Validation Procedure for Multiplex Antibiotic Immunoassays Using Flow-Based Chemiluminescence Microarrays.

Verena Katharina Meyer1, Daniela Meloni2, Fabio Olivo2, Erwin Märtlbauer3, Richard Dietrich3, Reinhard Niessner1, Michael Seidel4.   

Abstract

Small molecules like antibiotics or other pharmaceuticals can be detected and quantified, among others, with indirect competitive immunoassays. With regard to multiplex quantification, these tests can be performed as chemiluminescence microarray immunoassays, in which, in principle, the analyte in the sample and the same substance immobilized on the chip surface compete for a limited number of specific antibody binding sites. The amount of the specific primary antibody that has been bound to the surface is visualized by means of a chemiluminescence reaction.Validated quantitative confirmatory methods for the detection of contaminants, for example drug residues, in food samples usually comprise chromatographic analysis and spectrometric detection, e.g., HPLC-MS, GC-MS, or GC with electron capture detection. Here, we describe a validation procedure (according to the Commission Decision of the European Communities 2002/657/EC) for multiplex immunoassays performed as flow-through chemiluminescence microarrays, using the example of a small molecule microarray for the simultaneous detection of 13 antibiotics in milk. By this means, we suggest to accept multianalyte immunoassays as confirmatory methods as well, to benefit from the advantages of a fast automated method that does not need any pretreatment of the sample. The presented microarray chip is regenerable, so an internal calibration is implemented. Therefore, the analytical results are highly precise, combined with low costs (the aim for commercialization is less than 1 € per analyte per sample, this is significantly less than HPLC-MS).

Keywords:  Antibiotics; Chemiluminescence; Competitive immunoassay; Flow-based analysis platform; Microarrays; Regeneration; Residue analysis; Screening methods; Veterinary drugs

Mesh:

Substances:

Year:  2017        PMID: 27873208     DOI: 10.1007/978-1-4939-6584-7_13

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  3 in total

Review 1.  Electrochemical Aptasensors for Antibiotics Detection: Recent Achievements and Applications for Monitoring Food Safety.

Authors:  Gennady Evtugyn; Anna Porfireva; George Tsekenis; Veronika Oravczova; Tibor Hianik
Journal:  Sensors (Basel)       Date:  2022-05-12       Impact factor: 3.847

2.  The Simultaneous Detection of Multiple Antibiotics in Milk and Pork Based on an Antibody Chip Biosensor.

Authors:  Jiaxu Xiao; Nana Wei; Shuangmin Wu; Huaming Li; Xiaoyang Yin; Yu Si; Long Li; Dapeng Peng
Journal:  Biosensors (Basel)       Date:  2022-07-29

Review 3.  Antibiotic residues in milk: Past, present, and future.

Authors:  Sabbya Sachi; Jannatul Ferdous; Mahmudul Hasan Sikder; S M Azizul Karim Hussani
Journal:  J Adv Vet Anim Res       Date:  2019-07-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.