Literature DB >> 27867733

Multi-wavelength photoplethysmography method for skin arterial pulse extraction.

Jing Liu1, Bryan Ping-Yen Yan2, Wen-Xuan Dai1, Xiao-Rong Ding1, Yuan-Ting Zhang3, Ni Zhao4.   

Abstract

In this work, we present a multi-wavelength (MW) PPG method exploiting the wavelength dependence of light penetration in skin tissue to provide depth resolution of skin blood pulsation. The MW PPG system requires two to three light sources in different wavelengths and extracts the arterial blood pulsation through a multi-wavelength multi-layer light-skin interaction model, which removes the capillary pulsation (determined from the short-wavelength PPG signal) from the long-wavelength PPG signal using absorption weighting factors that are quasi-analytically calibrated. The extracted pulsations are used to calculate blood pressure (BP) through pulse transit time (PTT), and the results are compared with those obtained from the single wavelength PPG method. The comparative study is clinically performed on 20 subjects including 10 patients diagnosed with cardiovascular diseases and 10 healthy subjects. The result demonstrates that the MW PPG method significantly improves the measurement accuracy of systolic BP (SBP), reducing the mean absolute difference between the reference and the estimated SBP values from 5.7 mmHg (for single-wavelength PPG) to 2.9 mmHg (for three-wavelength PPG).

Entities:  

Keywords:  (070.6020) Continuous optical signal processing; (170.1470) Blood or tissue constituent monitoring

Year:  2016        PMID: 27867733      PMCID: PMC5102532          DOI: 10.1364/BOE.7.004313

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  15 in total

1.  THE CONTINUOUS MEASUREMENT OF ARTERIAL PULSE WAVE VELOCITY.

Authors:  G WELTMAN
Journal:  Med Electron Biol Eng       Date:  1964-04

Review 2.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

3.  The modified Beer-Lambert law revisited.

Authors:  L Kocsis; P Herman; A Eke
Journal:  Phys Med Biol       Date:  2006-02-15       Impact factor: 3.609

4.  Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head.

Authors:  E Okada; M Firbank; M Schweiger; S R Arridge; M Cope; D T Delpy
Journal:  Appl Opt       Date:  1997-01-01       Impact factor: 1.980

Review 5.  Measurement of properties and function of skin.

Authors:  P A Payne
Journal:  Clin Phys Physiol Meas       Date:  1991-05

6.  An efficient motion-resistant method for wearable pulse oximeter.

Authors:  Yong-Sheng Yan; Yuan-Ting Zhang
Journal:  IEEE Trans Inf Technol Biomed       Date:  2008-05

7.  Utility of the photoplethysmogram in circulatory monitoring.

Authors:  Andrew Reisner; Phillip A Shaltis; Devin McCombie; H Harry Asada
Journal:  Anesthesiology       Date:  2008-05       Impact factor: 7.892

8.  Estimation of optical pathlength through tissue from direct time of flight measurement.

Authors:  D T Delpy; M Cope; P van der Zee; S Arridge; S Wray; J Wyatt
Journal:  Phys Med Biol       Date:  1988-12       Impact factor: 3.609

9.  The relationship between arterial blood pressure and pulse transit time during dynamic and static exercise.

Authors:  G V Marie; C R Lo; J Van Jones; D W Johnston
Journal:  Psychophysiology       Date:  1984-09       Impact factor: 4.016

10.  Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template.

Authors:  Gary E Strangman; Zhi Li; Quan Zhang
Journal:  PLoS One       Date:  2013-08-01       Impact factor: 3.240

View more
  11 in total

Review 1.  Wireless and battery-free platforms for collection of biosignals.

Authors:  Tucker Stuart; Le Cai; Alex Burton; Philipp Gutruf
Journal:  Biosens Bioelectron       Date:  2021-01-23       Impact factor: 10.618

2.  Intraoperative Optical Monitoring of Spinal Cord Hemodynamics Using Multiwavelength Imaging System.

Authors:  Nicolas Mainard; Olivier Tsiakaka; Songlin Li; Julien Denoulet; Karim Messaoudene; Raphael Vialle; Sylvain Feruglio
Journal:  Sensors (Basel)       Date:  2022-05-19       Impact factor: 3.847

3.  The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time.

Authors:  Peyman Yousefian; Sungtae Shin; Azin Mousavi; Chang-Sei Kim; Ramakrishna Mukkamala; Dae-Geun Jang; Byung-Hoon Ko; Jongwook Lee; Ui Kun Kwon; Youn Ho Kim; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2019-07-23       Impact factor: 4.379

4.  Design of Multi-Wavelength Optical Sensor Module for Depth-Dependent Photoplethysmography.

Authors:  Sangjin Han; Donggeun Roh; Junyung Park; Hangsik Shin
Journal:  Sensors (Basel)       Date:  2019-12-10       Impact factor: 3.576

5.  Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.

Authors:  Pilar Martín-Escudero; Ana María Cabanas; Manuel Fuentes-Ferrer; Mercedes Galindo-Canales
Journal:  Biosensors (Basel)       Date:  2021-10-14

Review 6.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

Review 7.  The Current State of Optical Sensors in Medical Wearables.

Authors:  Erik Vavrinsky; Niloofar Ebrahimzadeh Esfahani; Michal Hausner; Anton Kuzma; Vratislav Rezo; Martin Donoval; Helena Kosnacova
Journal:  Biosensors (Basel)       Date:  2022-04-06

8.  A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China.

Authors:  Yongbo Liang; Zhencheng Chen; Guiyong Liu; Mohamed Elgendi
Journal:  Sci Data       Date:  2018-02-27       Impact factor: 6.444

Review 9.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

10.  A Textile Sleeve for Monitoring Oxygen Saturation Using Multichannel Optical Fibre Photoplethysmography.

Authors:  Hattan K Ballaji; Ricardo Correia; Serhiy Korposh; Barrie R Hayes-Gill; Francisco U Hernandez; Byron Salisbury; Stephen P Morgan
Journal:  Sensors (Basel)       Date:  2020-11-17       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.