Literature DB >> 18693507

An efficient motion-resistant method for wearable pulse oximeter.

Yong-Sheng Yan1, Yuan-Ting Zhang.   

Abstract

Reduction of motion artifact and power saving are crucial in designing a wearable pulse oximeter for long-term telemedicine application. In this paper, a novel algorithm, minimum correlation discrete saturation transform (MCDST) has been developed for the estimation of arterial oxygen saturation (SaO2), based on an optical model derived from photon diffusion analysis. The simulation shows that the new algorithm MCDST is more robust under low SNRs than the clinically verified motion-resistant algorithm discrete saturation transform (DST). Further, the experiment with different severity of motions demonstrates that MCDST has a slightly better performance than DST algorithm. Moreover, MCDST is more computationally efficient than DST because the former uses linear algebra instead of the time-consuming adaptive filter used by latter, which indicates that MCDST can reduce the required power consumption and circuit complexity of the implementation. This is vital for wearable devices, where the physical size and long battery life are crucial.

Entities:  

Mesh:

Year:  2008        PMID: 18693507     DOI: 10.1109/titb.2007.902173

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  7 in total

Review 1.  Unobtrusive sensing and wearable devices for health informatics.

Authors:  Ya-Li Zheng; Xiao-Rong Ding; Carmen Chung Yan Poon; Benny Ping Lai Lo; Heye Zhang; Xiao-Lin Zhou; Guang-Zhong Yang; Ni Zhao; Yuan-Ting Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

Review 2.  Wireless and battery-free platforms for collection of biosignals.

Authors:  Tucker Stuart; Le Cai; Alex Burton; Philipp Gutruf
Journal:  Biosens Bioelectron       Date:  2021-01-23       Impact factor: 10.618

3.  Multi-wavelength photoplethysmography method for skin arterial pulse extraction.

Authors:  Jing Liu; Bryan Ping-Yen Yan; Wen-Xuan Dai; Xiao-Rong Ding; Yuan-Ting Zhang; Ni Zhao
Journal:  Biomed Opt Express       Date:  2016-09-27       Impact factor: 3.732

4.  Adaptive motion artefact reduction in respiration and ECG signals for wearable healthcare monitoring systems.

Authors:  Zhengbo Zhang; Ikaro Silva; Dalei Wu; Jiewen Zheng; Hao Wu; Weidong Wang
Journal:  Med Biol Eng Comput       Date:  2014-10-02       Impact factor: 2.602

5.  Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry.

Authors:  Jeonghyun Kim; Philipp Gutruf; Antonio M Chiarelli; Seung Yun Heo; Kyoungyeon Cho; Zhaoqian Xie; Anthony Banks; Seungyoung Han; Kyung-In Jang; Jung Woo Lee; Kyu-Tae Lee; Xue Feng; Yonggang Huang; Monica Fabiani; Gabriele Gratton; Ungyu Paik; John A Rogers
Journal:  Adv Funct Mater       Date:  2016-11-25       Impact factor: 18.808

6.  Heart-rate tuned comb filters for processing photoplethysmogram (PPG) signals in pulse oximetry.

Authors:  Ludvik Alkhoury; Ji-Won Choi; Chizhong Wang; Arjun Rajasekar; Sayandeep Acharya; Sean Mahoney; Barry S Shender; Leonid Hrebien; Moshe Kam
Journal:  J Clin Monit Comput       Date:  2020-06-17       Impact factor: 2.502

Review 7.  A review of wearable sensors and systems with application in rehabilitation.

Authors:  Shyamal Patel; Hyung Park; Paolo Bonato; Leighton Chan; Mary Rodgers
Journal:  J Neuroeng Rehabil       Date:  2012-04-20       Impact factor: 4.262

  7 in total