Analysis of a Low Dose Protocol to Reduce Patient Radiation Exposure During Percutaneous Coronary Interventions.

Davide Maccagni1, Cosmo Godino2, Azeem Latib3, Lorenzo Azzalini2, Vittorio Pazzanese2, Alaide Chieffo2, Alberto Margonato2, Antonio Colombo3.   

Abstract

The cardiac catheterization laboratory is an important source of radiation for patients and operators and it is good practice to limit exposure as much as possible. The purpose of this study was to evaluate the effectiveness and impact of a radiological low dose protocol (LDP) in terms of reduction in patient radiation exposure during percutaneous coronary interventions (PCIs). From November 2014 to October 2015, 906 consecutive patients who underwent PCI were evaluated. Of these, 571 patients (63%) were treated with the standard dose protocol (SDP) of 15 frames per second for cine acquisition and standard settings for fluoroscopy, and 335 patients (37%) with the LDP of 7.5 frames per second for cine acquisition and low-dose settings for fluoroscopy. In the LDP group, we observed a significant reduction of kerma area product (53.3 LDP vs 115 SDP Gycm2, p <0.0001) and air kerma at interventional reference point (0.79 LDP vs 1.976 SDP Gy, p <0.0001). Marked differences were observed regarding the exceeding of International Commission on Radiological Protection and National Council on Radiation Protection and Measurements' air kerma at interventional reference point trigger level (cutoff for potential skin injuries), which were significantly lower in the LDP group (1.8% vs 7.2%, p <0.0001). Such difference was more relevant in complex PCI. In conclusion, the implementation of LDP allowed a marked reduction in patient dosimetric parameters for PCI and significantly reduced the risk of exceeding the International Commission on Radiological Protection/National Council on Radiation Protection and Measurements trigger levels for potential skin injuries.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27863695     DOI: 10.1016/j.amjcard.2016.09.044

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

Authors:  Davide Maccagni; Susanna Benincasa; Barbara Bellini; Luciano Candilio; Enrico Poletti; Mauro Carlino; Antonio Colombo; Lorenzo Azzalini
Journal:  Int J Cardiovasc Imaging       Date:  2018-03-23       Impact factor: 2.357

2.  Retrospective study of patients radiation dose during cardiac catheterization procedures.

Authors:  Beverley Osei; Lu Xu; Amanda Johnston; Sara Darko; Johnson Darko; Ernest Osei
Journal:  Br J Radiol       Date:  2019-05-14       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.